Guillaume Dutilleux

Prof. Guillaume Dutilleux

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2025 in Nature Ecology & Evolution
Verified
Journal Article
Open access
PDF file
SPStephen Pringle
Stephen Pringle
MDMartin Dallimer
Martin Dallimer
MGMark A. Goddard
Mark A. Goddard
LGLéni K. Le Goff
Léni K. Le Goff
EHEmma Hart
Emma Hart
ZDZoe Davies
Zoe Davies
With biodiversity loss escalating globally, a step change is needed in our capacity to accurately monitor species populations across ecosystems. Robotic and autonomous systems (RAS) offer technological solutions that may substantially advance terrestrial biodiversity monitoring, but this potential is yet to be considered systematically. We used a modified Delphi technique to synthesize knowledge from 98 biodiversity experts and 31 RAS experts, who identified the major methodological barriers that currently hinder monitoring, and explored the opportunities and challenges that RAS offer in overcoming these barriers. Biodiversity experts identified four barrier categories: site access, species and individual identification, data handling and storage, and power and network availability. Robotics experts highlighted technologies that could overcome these barriers and identified the developments needed to facilitate RAS-based autonomous biodiversity monitoring. Some existing RAS could be optimized relatively easily to survey species but would require development to be suitable for monitoring of more ‘difficult’ taxa and robust enough to work under uncontrolled conditions within ecosystems. Other nascent technologies (for instance, new sensors and biodegradable robots) need accelerated research. Overall, it was felt that RAS could lead to major progress in monitoring of terrestrial biodiversity by supplementing rather than supplanting existing methods. Transdisciplinarity needs to be fostered between biodiversity and RAS experts so that future ideas and technologies can be codeveloped effectively.

16 April 2018 in Freshwater Biology
Verified
Journal Article
Closed access
PDF file
GDGuillaume Dutilleux
Guillaume Dutilleux
CCCharlotte Curé
Charlotte Curé

1 July 2020 in Acta Acustica
Verified
Journal Article
Open access
PDF file
GDGuillaume Dutilleux
Guillaume Dutilleux
JFJean Fosset
Jean Fosset
While most of the countries over the world rely on sound-pressure-level-based limit values to regulate wind energy development, sound emergence as defined in ISO 1996-1 is used in a few national legislations but also in international guidelines. There is however no published evidence that sound emergence is a relevant noise descriptor for that kind of source, namely that there is a correlation between this metric and perception or annoyance. A listening test was carried out to evaluate the relative merits of sound pressure level and sound emergence as predictors of annoyance from wind turbine noise. The test samples consisted of 45 30-s wind turbine sounds at three different A-weighted sound pressure levels and five different signal-to-noise ratios. Thirty two persons rated the test samples according to the ISO 15666 standard scale in a dry room equipped with loudspeakers. The results indicate that short term annoyance is better predicted by A-weighted sound pressure levels than by sound emergence. It is also observed that sound emergence is a poor predictor of the audibility of wind turbine sounds.

GDGuillaume Dutilleux
Guillaume Dutilleux
Truls GjestlandTruls Gjestland
Truls Gjestland
Gaetano LicitraGaetano Licitra
Gaetano Licitra
In the vast majority of legislation on environmental noise, the metric used for expressing limit values is based on sound pressure levels. But some countries have introduced sound emergence limit values where the compliance of a noise-generating activity is defined as a maximum allowable difference between the sound pressure level with and without the regulated activity operating. This paper investigates the foundations and the merits of this kind of differential noise limit values. Our review of literature indicates that there is very little evidence supporting the use of differential noise limits over absolute ones. Moreover, while sound emergence limits seem to originate from consideration about audibility of the regulated noise source, they appear to give little insight into what is audible and what is not. Furthermore, both the definition and the practical measurement of sound emergence raise several challenges that compromise reproducibility. In addition, first, the reference to background noise makes it very difficult first to ascertain the conformity of noisy installations in the long run, second to effectively protect the community from excessive noise and third to evaluate conformity on the basis of simulations. When switching to another metric is not an option the paper makes recommendations toward a more reliable use of sound emergence.

2 August 2023 in Bioacoustics
Verified
Journal Article
Open access
GDGuillaume Dutilleux
Guillaume Dutilleux
BSBrett K. Sandercock
Brett K. Sandercock
JKJohn Atle Kålås
John Atle Kålås

1 February 2023 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
ERElise Ruaud
Elise Ruaud
GDGuillaume Dutilleux
Guillaume Dutilleux
While sound emergence is used in several countries to regulate wind energy development, there is no published evidence that it is a relevant noise descriptor for this purpose. In the present work, we carried out two listening tests to evaluate the merits of sound emergence. Three definitions of sound emergence were considered: the one in ISO 1996-1, sound emergence under audibility condition eUAC, and spectral emergence eSP. We also considered the specific to residual ratio and loudness metrics. In each listening test, the sound stimuli consisted of 48 sound stimuli at three A-weighted sound pressure levels {30, 40, 50} dB and four specific-to-residual ratios {−10,−5,0,+5} dB. The results lead to the conclusion that short term annoyance is better predicted by the total sound pressure level than by sound emergence, whatever the definition considered for the latter, or than by the specific to residual ratio. Short-term annoyance is slightly better predicted by eUAC than by e, while e is a better predictor than eSP. The total sound pressure level and the loudness metrics performed similarly. Furthermore, the results provide evidence that sound emergence is a poor predictor of the audibility of wind turbine sounds.