The metallurgical performance of a double-parameter oxygen lance was characterized using the prototype of a 260 t converter. The influences of nozzle arrangement on the cavity size, mixing ability and splashing capacity were discussed. The results demonstrated that the small-nozzle inclination has a greater impact on the cavity diameter, while the large-nozzle flow ratio has a greater impact on the cavity depth. The influence of the large-nozzle gas flow rate on the stirring strength is greater than that of the nozzle inclination. The maximum splash flux is located at the outer edge of the large nozzle farthest from the axis of the lance. The large-nozzle flow of the double-parameter lance shall be limited to less than 65% of the total flow to prevent the molten steel from splashing out of the converter. Many metallurgical indexes were improved by the application of the double-parameter lance under commercial production conditions.
4 February 2020 in Ironmaking & Steelmaking: Processes, Products and Applications
In oxygen steelmaking, one important aspect is to depict the splashing induced by the impingement of multiple jets quantitatively. In this paper, experiments were conducted to investigate the splash sheets. The results demonstrated that with the decrease of lance height, the sheet area increased, while the sheet height decreased. The sheet diameter was much less affected by the gas flow rate compared to the sheet height. The cavity width-to-depth ratio is a critical parameter affecting the sheet shape. The sheet area produced by the 5-nozzle jet was larger than that produced by the 6-nozzle jet. Taking the sheet area reduction as the critical condition where the cavity mode changes from splashing to penetrating, the critical lance height was investigated under various ejecting conditions. This was further represented by the blowing number as a normalized formula. At last, curve fitting illustrating the conditions that lead to the penetrating mode was conducted.
The jet behavior of interlaced multiple nozzles and the impingement of multiple jets onto the surface of the molten metal bath in a steelmaking converter are numerically studied. The interlaced jet hydrodynamic behaviors such as jet profile, coalescence characteristics, and dynamic parameter distributions penetration depth and impact area, as well as time-dependent evolution of liquid bath are discussed. The results are compared with traditional nozzles. It is found that the single nozzle characteristics of staggered jet are similar to those of traditional jet. However, two sets of staggered nozzles with different flow rate and inclination angle having a less disturbance flows, cause weaker coalescence of the jets and larger area surrounded by isovelocity in the molten pool. In the initial stage of the interaction between the interlaced nozzles and the molten pool, the “low stirring zone” is more likely to concentrate in the outer side near the furnace wall than in the center of the molten pool. Two cavities, one deep and one shallow, are formed on the bath surface. The average depth of the two cavities is similar to traditional nozzles, and the diameter of the cavity is increased by about 11% compared to traditional nozzles.
An oxygen lance represents a commonly used piece of equipment in converter steelmaking. Its jet characteristics and the interaction of these jets with the molten pool will directly affect the smelting effect and blowing time. This work investigates the oxygen lance of a 260 t converter in a steel plant. Through numerical simulations and physical experiments, the influence of the operating pressure, ambient temperature, top-blowing flow, lance position, and other operating parameters on the jet flow characteristics of the oxygen lance is studied. Furthermore, the oxygen lance interaction with the molten pool is analyzed. The results show that the operating pressure has little effect on the fusion distance of the jet; however, its size determines the impact force of the jet on the molten pool. In addition, the high-temperature environment causes the density of the jet fluid to decrease, the jet attenuation speed to decrease, the jet fusion speed to increase, and the degree of fusion to attenuate. Furthermore, the spray volume of the furnace mouth continues to increase upon increasing the top-blowing flow; by contrast, the spray volume first increases and then decreases as the gun position increases. The maximum spray volume of the furnace mouth occurs at the 35-de gun position; the diameter of the impact pit varies with the gun position. As the top-blowing flow increases, the depth of the impact pit increases with the decrease in the gun position and the increase in the top-blowing flow. The mixing time gradually reduces with the increase in the top-blowing flow and the decrease in the gun position.
The dynamic characteristics of supersonic double-parameter jets and their interaction with the molten pool were experimentally studied. The effects of jet inclination angles and gas flow ratios on gas intensity, coalescence characteristics, and dynamic parameter distributions were discussed. The characteristics of the cavity formed by the interaction of the jet and molten pool were revealed. The results show that the jet inclination angle has more influence on the jet coalescence compared with the gas flow rate. However, the gas flow ratio plays a decisive role in the velocity distribution along the jet centerline compared with the jet inclination angle. The velocity peaks of the double-parameter jets were obviously different at fixed axial distances. Compared with other variables, the small-nozzle inclination has a greater impact on the cavity diameter, while the large-nozzle flow ratio has a greater impact on the cavity depth. The depth and width of the cavity formed by the double-parameter jets are more advantageous than that formed by the single-parameter jets. Furthermore, the double-parameter jets were applied to the actual smelting of a 260t converter.