Larissa Panina

Dr. Larissa Panina

Institute of Novel Materials and Nanotechnology, National University of Science and Technology (NUST MISIS), 119049 Moscow, Russia

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DMDmitry Murzin
Dmitry Murzin
DMDes Mapps
Des Mapps
KLKateryna Levada
Kateryna Levada
VBVictor K. Belyaev
Victor K. Belyaev
Alexander OmelyanchikAlexander Omelyanchik
Alexander Omelyanchik
Valeria RodionovaValeria Rodionova
Valeria Rodionova
The development of magnetic field sensors for biomedical applications primarily focuses on equivalent magnetic noise reduction or overall design improvement in order to make them smaller and cheaper while keeping the required values of a limit of detection. One of the cutting-edge topics today is the use of magnetic field sensors for applications such as magnetocardiography, magnetotomography, magnetomyography, magnetoneurography, or their application in point-of-care devices. This introductory review focuses on modern magnetic field sensors suitable for biomedicine applications from a physical point of view and provides an overview of recent studies in this field. Types of magnetic field sensors include direct current superconducting quantum interference devices, search coil, fluxgate, magnetoelectric, giant magneto-impedance, anisotropic/giant/tunneling magnetoresistance, optically pumped, cavity optomechanical, Hall effect, magnetoelastic, spin wave interferometry, and those based on the behavior of nitrogen-vacancy centers in the atomic lattice of diamond.

21 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Larissa PaninaLarissa Panina
Larissa Panina
ADAbdukarim Dzhumazoda
Abdukarim Dzhumazoda
Makhsudsho Gayratovich NematovMakhsudsho Gayratovich Nematov
Makhsudsho Gayratovich Nematov
JAJunaid Alam
Junaid Alam
Alex V. TrukhanovAlex V. Trukhanov
Alex V. Trukhanov
Arcady ZhukovArcady Zhukov
Arcady Zhukov
Amorphous ferromagnetic materials in the form of microwires are of interest for the development of various sensors. This paper analyzes and argues for the use of microwires of two basic compositions of Co71Fe5B11Si10Cr3 and Fe3.9(4.9)Co64.82B10.2Si12Cr9(8)Mo0.08 as stress/strain and temperature sensors, respectively. The following properties make them suitable for innovative applications: miniature dimensions, small coercivity, low anisotropy and magnetostriction, tunable magnetic structure, magnetic anisotropy, and Curie temperature by annealing. For example, these sensors can be used for testing the internal stress/strain condition of polymer composite materials and controlling the temperature of hypothermia treatments. The sensing operation is based on the two fundamental effects: the generation of higher frequency harmonics of the voltage pulse induced during remagnetization in wires demonstrating magnetic bistability, and magnetoimpedance.

1 September 2019 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
ASA. I. Stognij
A. I. Stognij
ННН. Н. Новицкий
Н. Н. Новицкий
STSergei Trukhanov
Sergei Trukhanov
АТА.в. Труханов
А.в. Труханов
Larissa PaninaLarissa Panina
Larissa Panina
Yujie YangYujie Yang
Yujie Yang

10 March 2022 in Cells
Verified
Journal Article
Open access
PDF file
Larissa PaninaLarissa Panina
Larissa Panina
АГАнастасия Гуревич
Анастасия Гуревич
ABAnna Beklemisheva
Anna Beklemisheva
Alexander OmelyanchikAlexander Omelyanchik
Alexander Omelyanchik
KLKateryna Levada
Kateryna Levada
Valeria RodionovaValeria Rodionova
Valeria Rodionova
The importance of magnetic micro- and nanoparticles for applications in biomedical technology is widely recognised. Many of these applications, including tissue engineering, cell sorting, biosensors, drug delivery, and lab-on-chip devices, require remote manipulation of magnetic objects. High-gradient magnetic fields generated by micromagnets in the range of 103–105 T/m are sufficient for magnetic forces to overcome other forces caused by viscosity, gravity, and thermal fluctuations. In this paper, various magnetic systems capable of generating magnetic fields with required spatial gradients are analysed. Starting from simple systems of individual magnets and methods of field computation, more advanced magnetic microarrays obtained by lithography patterning of permanent magnets are introduced. More flexible field configurations can be formed with the use of soft magnetic materials magnetised by an external field, which allows control over both temporal and spatial field distributions. As an example, soft magnetic microwires are considered. A very attractive method of field generation is utilising tuneable domain configurations. In this review, we discuss the force requirements and constraints for different areas of application, emphasising the current challenges and how to overcome them.

6 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DYDzmitry Yakimchuk
Dzmitry Yakimchuk
VBVictoria Bundyukova
Victoria Bundyukova
JUJon Ustarroz
Jon Ustarroz
HTHerman Terryn
Herman Terryn
KBKitty Baert
Kitty Baert
Vladimir SivakovVladimir Sivakov
Vladimir Sivakov
The modern development of nanotechnology requires the discovery of simple approaches that ensure the controlled formation of functional nanostructures with a predetermined morphology. One of the simplest approaches is the self-assembly of nanostructures. The widespread implementation of self-assembly is limited by the complexity of controlled processes in a large volume where, due to the temperature, ion concentration, and other thermodynamics factors, local changes in diffusion-limited processes may occur, leading to unexpected nanostructure growth. The easiest ways to control the diffusion-limited processes are spatial limitation and localized growth of nanostructures in a porous matrix. In this paper, we propose to apply the method of controlled self-assembly of gold nanostructures in a limited pore volume of a silicon oxide matrix with submicron pore sizes. A detailed study of achieved gold nanostructures’ morphology, microstructure, and surface composition at different formation stages is carried out to understand the peculiarities of realized nanostructures. Based on the obtained results, a mechanism for the growth of gold nanostructures in a limited volume, which can be used for the controlled formation of nanostructures with a predetermined geometry and composition, has been proposed. The results observed in the present study can be useful for the design of plasmonic-active surfaces for surface-enhanced Raman spectroscopy-based detection of ultra-low concentration of different chemical or biological analytes, where the size of the localized gold nanostructures is comparable with the spot area of the focused laser beam.

21 January 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
YAYulia Alekhina
Yulia Alekhina
Valeria KolesnikovaValeria Kolesnikova
Valeria Kolesnikova
VRVladimir Rodionov
Vladimir Rodionov
NANikolai Andreev
Nikolai Andreev
Larissa PaninaLarissa Panina
Larissa Panina
Nikolai S. PerovNikolai S. Perov
Nikolai S. Perov
The tunable magnetic properties of amorphous ferromagnetic glass-coated microwires make them suitable for a wide range of applications. Accurate knowledge of the micromagnetic structure is highly desirable since it affects almost all magnetic properties. To select an appropriate wire-sample for a specific application, a deeper understanding of the magnetization reversal process is required, because it determines the measurable response (such as induced voltage waveform and its spectrum). However, the experimental observation of micromagnetic structure of micro-scale amorphous objects has strict size limitations. In this work we proposed a novel experimental technique for evaluating the microstructural characteristics of glass-coated microwires. The cross-sectional permeability distribution in the sample was obtained from impedance measurements at different frequencies. This distribution enables estimation of the prevailing anisotropy in the local region of the wire cross-section. The results obtained were compared with the findings of magnetostatic measurements and remanent state analysis. The advantages and limitations of the methods were discussed.