Full-scale shake table investigations are strongly required to understand the actual performance of storage racks and to improve the rack design guidelines. This paper presents the results of full-scale shake table tests on New Zealand standard storage rack frames with two-bay and two-level to determine the dynamic characteristics of a standard rack structure and to measure the damping of the system. The experimental program was conducted in three phases. First, the identification parameters including the natural frequency and damping of the system were determined through a series of preliminary tests. Then, shake table tests were performed to capture the inelastic response of rack frames under low to medium intensities of El-Centro ground motion. Finally, the shake-table tests were repeated with scaling down the time domain and broader ranges of ground motion intensities to consider the performance of taller rack systems. In addition, a comprehensive discussion on the damping of the system is also provided based on the test results. The performance of the rack frame is described through an extensive set of measurements, including rack displacement, pallet sliding, the acceleration of a concrete block and rack frame and the damping of the system in the down-aisle direction. The results indicate that the standard rack frames are able to endure large inelastic deformations without loss of stability.
Cold-formed steel (CFS) storage rack structures are extensively used in various industries to store products in safe and secure warehouses before distribution to the market. Thin-walled open profiles that are typically used in storage rack structures are prone to loss of stability due to different buckling modes such as local, distortional, torsional and flexural, or any interaction between these modes. In this paper, an efficient way of increasing ultimate capacity of upright frames under compression load is proposed using bolts and spacers which are added externally to the section with certain pitches along the height. Hereinto, experimental tests on 81 upright frames with different thicknesses and different heights were conducted, and the effect of employing reinforcement strategies was examined through the failure mode and ultimate load results. Non-linear finite element analyses were also performed to investigate the effect of different reinforcement spacing on the upright performance. The results showed that the reinforcement method could restrain upright flange and consequently increase the distortional strength of the upright profiles. This method can also be effective for any other light gauged steel open section with perforation. It was also observed that the reinforcement approach is much more useful for short length upright frames compared to the taller frames.
An experimental test was carried out on a 3/10 scale subassemblage in order to investigate the progressive collapse behavior of reinforced concrete (RC) structures. Investigation of alternative load paths and resistance mechanisms in scaled subassemblage and differences between the results of full-scale and scaled specimens are the main goals of this research. Main characteristics of specimen response including load-displacement curve, mechanism of formation and development of cracks, and failure mode of the scaled specimen had good agreement with the full-scale specimen. In order to provide a reliable numerical model for progressive collapse analysis of RC beam-column subassemblages, a macromodel was also developed. First, numerical model was validated with experimental tests in the literature. Then, experimental results in this study were compared with validated numerical results. It is shown that the proposed macromodel can provide a precise estimation of collapse behavior of RC subassemblages under the middle column removal scenario. In addition, for further evaluation, using the validated numerical model, parametric study of new subassemblages with different details, geometric and boundary conditions, was also done.
8 December 2017 in Advances in Structural Engineering
A simplified theoretical model is developed in the present study in order to predict the general behavior and resistance of reinforced concrete frames under column removal scenarios. The proposed model defines the load–deflection response of the middle joint above the removed column based on a four-stage procedure: classical beam mechanism stage, arching stage, transient stage, and catenary stage. A comprehensive evaluation study using two validation approaches is performed in order to investigate the reliability of the introduced model. For validation of theoretical model, the results of a comprehensive finite element method and experimental data were utilized and the results were compared with the theoretical model. The results demonstrated that the proposed theoretical procedure can establish a reliable foundation for progressive collapse assessment of reinforced concrete frame structures. The proposed model can also predict behavior of symmetrical frames, and this was validated by good agreement between finite element results and the results of the proposed numerical model.