Hamid Khodakarami

Dr. Hamid Khodakarami

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2018 in npj Parkinson's Disease
Verified
Journal Article
Open access
PDF file
SMSarah McGregor
Sarah McGregor
PCPhilip Churchward
Philip Churchward
KSKatarzyna Soja
Katarzyna Soja
DODenise O’dRiscoll
Denise O’dRiscoll
MBMichelle Braybrook
Michelle Braybrook
MHMalcolm Horne
Malcolm Horne
Sleep disturbances are common in Parkinson’s disease (PD). We used the Parkinson’s KinetiGraph (PKG), an objective movement recording system for PD to assess night time sleep in 155 people aged over 60 and without PD (controls), 72 people with PD (PwP) and 46 subjects undergoing a Polysomnogram (PSG: 36 with sleep disorder and 10 with normal sleep). The PKG system uses a wrist worn logger to capture acceleration and derive a bradykinesia score (BKS) every 2 min over 6 days. The BKS ranges from 0–160 with higher scores associated with lesser mobility. Previously we showed that BKS > 80 were associated with day time sleep and used this to produce scores for night time sleep: Efficiency (Percent time with BKS > 80), Fragmentation (Average duration of runs of BKS > 80) and Sleep Quality (BKS > 111 as a representation of atonia). There was a fair association with BKS score and sleep level as judged by PSG. Using these PKG scores, it was possible to distinguish between normal and abnormal PSG studies with good Selectivity (86%) and Sensitivity (80%). The PKG’s sleep scores were significantly different in PD and Controls and correlated with a subject’s self-assessment (PDSS 2) of the quality, wakefulness and restlessness. Using both the PDSS 2 and the PKG, it was apparent that sleep disturbances were apparent early in disease in many PD subjects and that subjects with poor night time sleep were more likely to have day time sleepiness. This system shows promise as a quantitative score for assessing sleep in Parkinson’s disease.

25 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
HKHamid Khodakarami
Hamid Khodakarami
LRLucia Ricciardi
Lucia Ricciardi
MCMaria Fiorella Contarino
Maria Fiorella Contarino
RPRajesh Pahwa
Rajesh Pahwa
KLKelly E. Lyons
Kelly E. Lyons
MHMalcolm Horne
Malcolm Horne
The response to levodopa (LR) is important for managing Parkinson’s Disease and is measured with clinical scales prior to (OFF) and after (ON) levodopa. The aim of this study was to ascertain whether an ambulatory wearable device could predict the LR from the response to the first morning dose. The ON and OFF scores were sorted into six categories of severity so that separating Parkinson’s Kinetigraph (PKG) features corresponding to the ON and OFF scores became a multi-class classification problem according to whether they fell below or above the threshold for each class. Candidate features were extracted from the PKG data and matched to the class labels. Several linear and non-linear candidate statistical models were examined and compared to classify the six categories of severity. The resulting model predicted a clinically significant LR with an area under the receiver operator curve of 0.92. This study shows that ambulatory data could be used to identify a clinically significant response to levodopa. This study has also identified practical steps that would enhance the reliability of this test in future studies.

15 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
HKHamid Khodakarami
Hamid Khodakarami
PFParisa Farzanehfar
Parisa Farzanehfar
MHMalcolm Horne
Malcolm Horne
Device-assisted therapies (DAT) benefit people with Parkinsons Disease (PwP) but many referrals for DAT are unsuitable or too late, and a screening tool to aid in identifying candidates would be helpful. This study aimed to produce such a screening tool by building a classifier that models specialist identification of suitable DAT candidates. To our knowledge, this is the first objective decision tool for managing DAT referral. Subjects were randomly assigned to either a construction set (n = 112, to train, develop, cross validate, and then evaluate the classifier’s performance) or to a test set (n = 60 to test the fully specified classifier), resulting in a sensitivity and specificity of 89% and 86.6%, respectively. The classifier’s performance was then assessed in PwP who underwent deep brain stimulation (n = 31), were managed in a non-specialist clinic (n = 81) or in PwP in the first five years from diagnosis (n = 22). The classifier identified 87%, 92%, and 100% of the candidates referred for DAT in each of the above clinical settings, respectively. Furthermore, the classifier score changed appropriately when therapeutic intervention resolved troublesome fluctuations or dyskinesia that would otherwise have required DAT. This study suggests that information from objective measurement could improve timely referral for DAT.

9 March 2017 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
HKHamid Khodakarami
Hamid Khodakarami
DCDi Che
Di Che
WSWilliam Shieh
William Shieh
We derive the closed-form information capacity of optically amplified polarization modulation with direct detection and show that it exceeds that of three parallel intensity modulated direct detection systems.

1 May 2011
Verified
Conference Paper
Closed access
HKHamid Khodakarami
Hamid Khodakarami
FLFarshad Lahouti
Farshad Lahouti
Wireless cooperative communication through link adaptation with untrusted relay assignment is considered. Using sharp channel codes in different transmission modes, reliability for destination and security in the presence of untrusted relays are provided through rate and power allocation. Scenarios with single available relay and opportunistic relaying in the presence of multiple relays are investigated. These scenarios are analyzed separately in terms of performance over Rayleigh fading channel for constant power and adaptive power transmission. In constant power case, closed form expressions for average spectral efficiency is derived through an effective approximation. Retaining the sum transmission power of source and relay unchanged, the performance of system is enhanced through power allocation. Numerical results reflect the effectiveness of the approximations for analytic performance evaluation when comparing to the simulation results.

27 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
HKHamid Khodakarami
Hamid Khodakarami
LRLucia Ricciardi
Lucia Ricciardi
MCMaria Fiorella Contarino
Maria Fiorella Contarino
RPRajesh Pahwa
Rajesh Pahwa
KLKelly E. Lyons
Kelly E. Lyons
MHMalcolm Horne
Malcolm Horne
The authors wish to make the following erratum to this paper