Health-promoting behaviour is an important concept for health education. Unfortunately, there is a dearth of validated instruments to measure levels of health-promoting behaviour in the Malaysian context. The purpose of this study was to validate a Malay-language version of the Health-Promoting Lifestyle Profile II (HPLP-II) using a confirmatory approach. Participants were 997 university undergraduate students, with a mean age of 21 years (SD = 1.58). The majority of the participants (80.4%) were female. Health-promoting behaviour was assessed using the 52-item HPLP-II, which measures six components of health-promoting behaviour outcomes. HPLP-II was translated into the Malay language using standard forward and backward translation procedures. Participants then completed the HPLP-II Malay version (HPLP-II-M). Confirmatory factor analysis (CFA) was conducted using Mplus 8.0 software on the six domains of HPLP-II-M model. The CFA result based on the hypothesised measurement model of six factors was aligned with the original HPLP-II, except for two low loading items which were subsequently removed from the CFA analysis. The final CFA measurement model with 50 items resulted in a good fit to the data based on RMSEA and SRMR fit indices (RMSEA = 0.046, 90%CI = 0.045, 0.048, SRMR = 0.062). The construct reliabilities for the HPLP-II-M subscales were acceptable, ranging from 0.737 to 0.878. The HPLP-II-M with six components of health-promoting behaviour outcomes and 50 items was considered valid and reliable for the present Malaysian sample.
Background: Excessive screen time in young children is associated with many harmful consequences including screen dependency. Research has shown a worrying prevalence of media-related dependency among adolescents and pre-school children. There are a few available questionnaires among adolescents but none for pre-school children. This study aimed to design and validate a questionnaire to assess screen dependency among pre-school children aged 4 to 6 years old. Methodology: A cross-sectional two-phase study was carried out to develop the scale. In phase 1, a preliminary parent-report measure questionnaire was developed in Bahasa Malaysia. Later, it was sent to four experts for content validity followed by face validity. In Phase 2, a total of 386 parents of pre-school children aged 4 to 6 years old, split into two samples, were involved in the field study for exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). Result: Sample 1 was used to perform EFA to determine the factorial structure of the SDS. All items with a factor loading of >0.4 were included. Sample 2 was used to perform the CFA. RMSEA and CFI analysis showed that the SDS has a good fit and confirms the dimensional structure found via EFA. The final questionnaire consists of 15 items with a 4 factors’ structure and has excellent internal consistency reliability. Conclusions: The Screen Dependency Scale (SDS) is a reliable and valid questionnaire to detect screen dependency among pre-school children aged 4 to 6 years old in Malaysia.
Abdominal bloating (AB), a common complaint that affects quality of life and disturbs psychological well-being, is largely a behavioral-driven disorder. We aimed to develop and validate a new health belief of bloating (HB-Bloat) scale in the Malay language. The initial item pool was developed based on the theory of planned behavior, empirical literatures, expert review and in-depth interviews. Using the population with bloating (diagnosed based on the Rome IV criteria and pictogram), exploratory and confirmatory factor analytical approaches (EFA and CFA, respectively) were utilized to explore and confirm the domains in the new scale. There were 150 and 323 respondents in the EFA and CFA, respectively. There were 45 items in the initial scale, but it was reduced to 32 items after content validity and pre-testing. In EFA, 17 items with three (3) structure factors (attitude 4 items, subjective norm 7 items, and perceived behavior control 6 items) were identified. Total variance explained by the EFA model was 40.92%. The Cronbach alpha of the three (3) factors ranged from 0.61 to 0.79. With CFA, the three factors model was further tested. Five problematic items were identified and removed. The final measurement model fit the data well (root mean square error of approximation (RMSEA (90% CI) = 0.054 (0.038, 0.070), Comparative Fit Index (CFI) = 0.941, Tucker–Lewis Fit Index (TLI) = 0.924, and standardized root mean squared residual (SRMR) = 0.044). The construct reliability of the final measurement model ranged from 0.76 to 0.84. As a conclusion, the new HB-Bloat scale is a valid and reliable tool for assessment of health beliefs in bloating.
1 September 2024 in Asian Journal of Sport and Exercise Psychology
Background: Health management strategies may help patients with abdominal bloating (AB), but there are currently no tools that measure behaviour and awareness. This study aimed to validate and verify the dimensionality of the newly-developed Health Promoting Behaviour for Bloating (HPB-Bloat) scale. Methods: Based on previous literature, expert input, and in-depth interviews, we generated new items for the HPB-Bloat. Its content validity was assessed by experts and pre-tested across 30 individuals with AB. Construct validity and dimensionality were first determined using exploratory factor analysis (EFA) and Promax rotation analysis, and then using confirmatory factor analysis (CFA). Results: During the development stage, 35 items were generated for the HPB-Bloat, and were maintained following content validity assessment and pre-testing. One hundred and fifty-two participants (mean age of 31.27 years, 68.3% female) and 323 participants (mean age of 27.69 years, 59.4% male) completed the scale for EFA and CFA, respectively. Using EFA, we identified 20 items that we divided into five factors: diet (five items), health awareness (four items), physical activity (three items), stress management (four items), and treatment (four items). The total variance explained by the EFA model was 56.7%. The Cronbach alpha values of the five factors ranged between 0.52 and 0.81. In the CFA model, one problematic latent variable (treatment) was identified and three items were removed. In the final measurement model, four factors and 17 items fit the data well based on several fit indices (root mean square error of approximation (RMSEA) = 0.044 and standardized root mean squared residual (SRMR) = 0.052). The composite reliability of all factors in the final measurement model was above 0.60, indicating acceptable construct reliability. Conclusion: The newly developed HPB-Bloat scale is valid and reliable when assessing the awareness of health-promoting behaviours across patients with AB. Further validation is needed across different languages and populations.
Abdominal bloating (AB) is a prevalent and bothersome symptom, but there are no specific measures for severity and quality of life (QoL) other than the Bloating Severity Questionnaire (BSQ) and Bloating Quality of Life (BLQoL). We aimed to translate the BSQ and BLQoL into the Malay language and to validate them using exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) approaches. The 12-item BSQ has two components, seven-item severity in general (SevGen) and five-item severity in the past 24 h (Sev24), and BLQOL has five items. Translation to the Malay language (BSQ-M and BLQoL-M) was performed using standard forward and backward processes. EFA followed by CFA were performed in participants with AB due to functional bowel disorders, with the purpose of examining the validity and reliability of the questionnaires translated into Malay. After EFA with 152 participants, all the items of BSQ-M remained in the model. Total variance extracted was 53.26% for BSQ-M and 58.79% for BLQoL-M. The internal consistency based on Cronbach’s alpha values was 0.52 for SevGen, 0.86 for Sev24, and 0.81 for BLQoL-M. After performing CFA with another 323 participants, the final measurement model for BSQ-M and BLQoL-M fit the data well in terms of several fit indices (BSQ-M: root mean square error of approximation (RMSEA) = 0.050, Comparative Fit Index (CFI) = 0.966, Tucker–Lewis Fit Index (TLI) = 0.956, and standardized root mean squared residual (SRMR) = 0.051; BLQoL-M: RMSEA = 0.071, CFI = 0.985, TLI = 0.962, SRMR = 0.021). The composite reliability for BSQ-M and BLQoL-M were satisfactory (SevGen = 0.83, Sev24 = 0.89, BLQoL = 0.80). The intraclass correlation (ICC) results showed excellent stability for BSQ-M and BLQoL-M, ranging from 0.74 to 0.93. The Malay language versions of BSQ-M and BLQoL-M are valid and reliable instruments for measuring the severity and QoL of AB for the Asian population with functional bowel disorders.