Samuel Admasie

Dr. Samuel Admasie

Sungkyunkwan University, Suwon, Gyeonggi, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2021 in IEEE Access
Verified
Journal Article
Open access
TGTeke Gush
Teke Gush
CKChul-Hwan Kim
Chul-Hwan Kim
SASamuel Admasie
Samuel Admasie
JKJi-Soo Kim
Ji-Soo Kim
JSJin-Sol Song
Jin-Sol Song
In this study, an optimal reactive power (Volt/VAr) control of smart inverters for photovoltaic (PV) and battery energy storage systems (BESSs) to improve the PV hosting capacity (PVHC) of distribution networks is proposed. The primary objective of the proposed method is to improve the PVHC of a distribution network by determining the optimal oversize, dispatch, and control setting of the Volt/VAr functions of the smart inverters for both PVs and BESSs. Concurrently, the optimal locations of the PVs and BESSs are determined. The problem is formulated as a multi-objective mixed-integer nonlinear optimization to maximize the PVHC and minimize the voltage deviation simultaneously. A bio-inspired metaheuristic optimization method, i.e., the slime mould algorithm (SMA), is employed to solve the optimization problem. To assess the efficacy of the proposed PVHC improvement method, extensive simulations are conducted on an IEEE 33-node system using MATLAB software. The simulation results verify that the proposed method improves the PVHC of the distribution network compared to different cases and the default Volt/VAr control settings of the smart inverters. Furthermore, the SMA optimization method provides superior performance in finding the optimal PVHC of a distribution network compared to the conventional metaheuristic optimization methods.

1 November 2018 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
TGTeke Gush
Teke Gush
SBSyed Basit Ali Bukhari
Syed Basit Ali Bukhari
RHRaza Haider
Raza Haider
SASamuel Admasie
Samuel Admasie
YOYun-Sik Oh
Yun-Sik Oh
CKChul-Hwan Kim
Chul-Hwan Kim

1 January 2020 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Closed access
SASamuel Admasie
Samuel Admasie
SBSyed Basit Ali Bukhari
Syed Basit Ali Bukhari
TGTeke Gush
Teke Gush
RHRaza Haider
Raza Haider
CKChul-Hwan Kim
Chul-Hwan Kim

1 December 2019 in Electric Power Systems Research
Verified
Journal Article
Closed access
SASamuel Admasie
Samuel Admasie
SBSyed Basit Ali Bukhari
Syed Basit Ali Bukhari
RHRaza Haider
Raza Haider
TGTeke Gush
Teke Gush
CKChul-Hwan Kim
Chul-Hwan Kim

28 July 2021 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
AHArif Hussain
Arif Hussain
CKChul-Hwan Kim
Chul-Hwan Kim
SASamuel Admasie
Samuel Admasie
One of the crucial challenges of the distribution network is the unintentionally isolated section of electricity from the power network, called unintentional islanding. Unintentional islanding detection is severed when the local generation is equal to or closely matches the load requirement. In this paper, both ensemble learning and canonical methods are implemented for the islanding detection technique of synchronous machine‐based distributed generation. The ensemble learning models for this study are random forest (RF) and Ada boost, while the canonical methods are multi‐layer perceptron (MLP), decision tree (DT), and support vector machine (SVM). The training and testing parameters for this technique are the total harmonic distortion (THD) of both current and voltage signals. THD is the most important parameter of power quality monitoring under islanding scenarios. The parameter and data extraction from the test system is executed in a MATLAB/Simulink environment, whereas the training and testing of the presented techniques are implemented in Python. Performance indices such as accuracy, precision, recall, and F 1 score are used for evaluation, and both ensemble learning models and canonical models demonstrate good performance. Ada‐boost shows the highest accuracy among all the five models with original data, while RF is robust and gives the best results with noisy data (20 and 30 dB) because of its ensemble nature.

26 February 2024 in Energy Policy
Verified
Journal Article
Open access
LALyden Andrew
Lyden Andrew
SASamuel Admasie
Samuel Admasie
Peter ConnorPeter Connor
Peter Connor
RRRenaldi Renaldi
Renaldi Renaldi
SWStephen David Watson
Stephen David Watson