Dumitru-Cristian Tranca

Dr. Dumitru-Cristian Tranca

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Alexandru-Viorel PalaceanAlexandru-Viorel Palacean
Alexandru-Viorel Palacean
DTDumitru-Cristian Tranca
Dumitru-Cristian Tranca
RRRazvan Rughinis
Razvan Rughinis
DRDaniel Rosner
Daniel Rosner
Considering the widespread presence of switching devices on the power grid (including renewable energy system inverters), network distortion is more prominent. To maximize network efficiency, our goal is to minimize these distortions. Measuring the voltage and current total harmonic distortion (THD) using power meters and other specific equipment, and assessing power factor and peak currents, represents a crucial step in creating an efficient and stable smart grid. In this paper, we propose a power meter capable for measuring both standard electrical parameters and power quality parameters such as the voltage and current total harmonic distortion factors. The resulting device is compact and DIN-rail-mountable, occupying only three modules in an electrical cabinet. It integrates both wired and wireless communication interfaces and multiple communication protocols, such as Modbus RTU/TCP and MQTT. A microSD card can be used to store the device configuration parameters and to record the measured values in case of network fault events, the device’s continuous operation being ensured by the integrated backup battery in this situations. The device was calibrated and tested against three industrial power meters: Siemens SENTRON PAC4200, Janitza UMG-96RM, and Phoenix Contact EEM-MA400, obtaining an overall average measurement error of only 1.22%.

15 October 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Victor StoicaVictor Stoica
Victor Stoica
Alexandru-Viorel PalaceanAlexandru-Viorel Palacean
Alexandru-Viorel Palacean
DTDumitru-Cristian Tranca
Dumitru-Cristian Tranca
FSFlorin-Alexandru Stancu
Florin-Alexandru Stancu
IoT (Internet of Things)-enabled solar irradiance sensors are evolving toward energy harvesting, interoperability, and open-source availability, yet current solutions remain either costly, closed, or limited in robustness. Based on a thorough literature review and identification of future trends, we propose an open-source smart wireless sensor that employs a small photovoltaic module simultaneously as sensing element and energy harvester. The device integrates an ESP32 microcontroller, precision ADC (Analog-to-Digital converter), and programmable load to sweep the PV (photovoltaic) I–V (Current–Voltage) curve and compute irradiance from electrical power and solar-cell temperature via a calibrated third-order polynomial. Supporting Modbus RTU (Remote Terminal Unit)/TCP (Transmission Control Protocol), MQTT (Message Queuing Telemetry Transport), and ZigBee, the sensor operates from batteries or supercapacitors through sleep–wake cycles. Validation against industrial irradiance meters across 0–1200 W/m2 showed average errors below 5%, with deviations correlated to irradiance volatility and sampling cadence. All hardware, firmware, and data-processing tools are released as open source to enable reproducibility and distributed PV monitoring applications.

3 March 2026 in Results in Engineering
Verified
Journal Article
Open access
MBMihai Boni
Mihai Boni
MBMugurel Balan
Mugurel Balan
JSJ. Benedikt Schmidt
J. Benedikt Schmidt
JBJan Breitenbach
Jan Breitenbach
IAIonut R. Andrei
Ionut R. Andrei
IRIlia V. Roisman
Ilia V. Roisman

23 September 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NTNicoleta Alexandra Tranca
Nicoleta Alexandra Tranca
NPNoela-Elena Pîrleci
Noela-Elena Pîrleci
DTDumitru-Cristian Tranca
Dumitru-Cristian Tranca
Victor StoicaVictor Stoica
Victor Stoica
Dinu ŢurcanuDinu Ţurcanu
Dinu Ţurcanu
This study compares active-computation energy and latency for twelve compression, security/integrity and signal-processing workloads on ESP32, RP2040 and STM32F446. Common scalar C kernels process fixed 2048-byte inputs on one application core under two operating profiles: maximum nominal CPU clocks of 240, 200 and 180 MHz, respectively, and a common nominal 160 MHz. A Nordic PPK2 supplies each target domain at 3.3 V and records the current and one execution marker at nominal 100 kS/s. External regulators are removed on ESP32/RP2040; Nucleo retains its LDO with JP6 open. Sixty separate power-on captures provide ten observations per board and profile for arithmetic means and sample standard deviations. Energy integrates the full RUN current without baseline subtraction. At maximum clocks, ESP32 has the lowest observed mean latency for ten workloads, RP2040 for LZ77 and STM32F446 for DCT. At 160 MHz, the counts become six, one and five; minimum mean energy is distributed across six, two and four workloads. Relative to the maximum-clock profiles, ESP32’s mean energy falls by 1.29–3.54%, whereas RP2040’s rises by 3.35–4.00%. STM32’s mean energy is lower in eleven workloads but 15.38% higher for FIR. Equal nominal CPU frequency does not equalize internal supply settings, memory clocks or software execution. These results support the workload-specific comparison of documented operating configurations. The small cross-profile energy changes remain descriptive because capture SD characterizes repeatability, while absolute accuracy and cross-session systematic errors are not fully quantified.