Craig Baguley

Dr. Craig Baguley

School of Electrical and Electronic Engineering, Auckland University of Technology, 1010 Auckland, New Zealand

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
XLXin Lin
Xin Lin
Ramon ZamoraRamon Zamora
Ramon Zamora
CBCraig Baguley
Craig Baguley
ASAnurag Srivastava
Anurag Srivastava
This article proposes a hybrid method (HM) to improve the accuracy of short-term individual residential load forecasting. The HM includes an ensemble model (EM), deep ensemble model (DEM), and thermal dynamic model expressed by resistance-capacitance (RC). The EM consists of three predictors of support vector machine (SVM), back propagation neural network (BPNN), and generalized regression neural network (GRNN). The genetic algorithm (GA) is used to optimize SVM and BPNN to enhance their performance. The DEM includes multiple bi-directional long-short term memory (Bi-LSTM) networks. The Bayesian algorithm (BA) is used to optimize the hyperparameters of the Bi-LSTM. The outputs of individual predictors are aggregated using an optimal trimmed algorithm. At first, the total load is separated into the heater and air conditioning (HAC), and non-HAC loads. Then, the RC model is presented to predict the indoor temperature, which integrates outdoor weather and less HAC historical data as the input of the EM to forecast the HAC load. After that, non-HAC loads are further divided into electric lighting and other loads. A daylight equation is used to calculate the illuminance, which is combined with less lighting historical data as the input of DEM to predict electric lights usage. Then, other loads are captured by DEM through less historical data. Finally, the total load is obtained by combining the predicted HAC and non-HAC loads. The datasets from the UMass Smart Microgrid and Flexhouse projects are used to test the proposed method. The comparison with existing models proves that the presented model can provide accurate short-term individual load forecasting.

19 January 2021 in IEEE Access
Verified
Journal Article
Open access
XLXin Lin
Xin Lin
Ramon ZamoraRamon Zamora
Ramon Zamora
CBCraig Baguley
Craig Baguley
State of charge (SoC) imbalance and dc bus voltage deviations are significant issues for distributed battery energy storage systems in autonomous dc microgrid applications. Accordingly, a high-pass filter (HPF) based SoC balancing method is proposed to achieve SoC balance by considering different SoCs and capacities; A band-pass filter (BPF) based power droop control is used to accomplish power-sharing and voltage compensation. Through this approach, battery storage units (BSUs) with higher SoC and capacity deliver more power during discharging mode than those with lower SoC and capacity. During charging mode, those BSUs with higher SoC and lower capacity are controlled to absorb less power than those with higher capacity and lower SoC. Therefore, SoC balance can be achieved between distributed BSUs. Further, the dc bus voltage is maintained within the desired range by adopting the proposed method. In addition, the control method employed also considers the impact of line resistance. The proposed control strategy is implemented in a fully decentralized way which does not require any communication link, while maintaining system stability. MATLAB/Simulink and processor-in-the loop (PIL) simulation results verify that the proposed control strategy is effective and feasible.

2 July 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MBMichael Bunn
Michael Bunn
BDBhaba Priyo Das
Bhaba Priyo Das
Boon-Chong SeetBoon-Chong Seet
Boon-Chong Seet
CBCraig Baguley
Craig Baguley
The increasing penetration of electric vehicles and distributed generation into distribution networks is giving rise to higher, more volatile and bi-directional energy flows through distribution transformers (DTs). To minimise future capital expenditure, improved DT design approaches are required. Therefore, a novel DT design approach “design for maximum utilisation” is proposed. It incorporates manufacturer and customer-sourced empirical data to achieve a desired DT retirement age and utilisation rate, and allows for transient operation beyond DT nameplate rating through accurately accounting for thermal inertia. Novelty derives not only from a design approach based on maximising DT utilisation, but also allowing for the fact that winding insulation may not be the most critical factor affecting a DT's lifetime. Using the proposed approach DT capital expenditure and utilisation constraints can be optimised at a planning stage. The algorithm is applied and validated.

21 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
YAYuana Putra Adianto
Yuana Putra Adianto
CBCraig Baguley
Craig Baguley
UMUdaya Kumara Madawala
Udaya Kumara Madawala
NHNanang Hariyanto
Nanang Hariyanto
SSSuwarno Suwarno
Suwarno Suwarno
TKTeguh Kurniawan
Teguh Kurniawan
Charge scheduling can mitigate against issues arising from excessive electric vehicle (EV) charging loads and is commonly implemented using time-of-use pricing. A charge scheduling strategy to suit vertically structured power systems without relying on time-of-use pricing has not yet been reported, despite being needed by industry. Therefore, a novel charge scheduling strategy to meet this need is proposed in this paper. Key aspects include the provision of a decision-making framework that accommodates for the considerations of transmission and distribution network operators, and the allowance for dynamically changing charging loads through timely forecast updates with reduced communication requirements. A case study based on the Indonesian Java-Bali power system is undertaken to demonstrate the strategy’s effectiveness. Different and realistic EV uptake scenarios are considered, using probabilistic modeling, survey work, and a Monte Carlo modeling approach. Even under slow EV charging conditions case study results show assets are overloaded and high electricity production costs are incurred. These are alleviated through adopting the proposed strategy.

9 February 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
XLXin Lin
Xin Lin
Ramon ZamoraRamon Zamora
Ramon Zamora
CBCraig Baguley
Craig Baguley
This article proposes a comprehensive multi-functional controller for a hybrid energy storage system (HESS), including a battery and supercapacitor (SC). In the presented method, a V -d P /dt is proposed to control the output power of the battery converter with a slow dynamic response. The traditional V - P droop is employed to regulate the SC converter to give a fast response. The dc bus voltage can be maintained in a safe range by the SC converter control so that no voltage recovery loop is required. Hence, the order of the overall control system and the complexity of parameter design can be reduced. In addition, a novel consensus-based voltage compensator is proposed to achieve the state of charge (SoC) balance and accurate power sharing among batteries. Then, an SoC restoration of the SC is used to address the leakage current and ensure sufficient energy for future use. Next, a power management scheme (PMS) is proposed to protect the batteries from over-use under different operating modes. Finally, the output impedance characteristics, control system design, and stability analysis are elaborated. The processor in the loop (PIL) simulation results verified the effectiveness and feasibility of the proposed control method.

20 November 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
BNBalarabe Nkom
Balarabe Nkom
ATAdam P. R. Taylor
Adam P. R. Taylor
CBCraig Baguley
Craig Baguley
The implementation of Powerline Communication (PLC) on Single Wire Earth Return (SWER) grids requires high frequency earth path characterization. The empirical determination of these characteristics is not practical for large grids. Analytical expressions may be used to estimate the high frequency characteristics of earth paths, however this paper shows that this approach can lead to errors when modeling line-to-earth path PLC channels. Therefore, a hybrid empirical/analytical earth path characterization method, based on heuristic correlations of measurement results with a lossy capacitor model, is hereby proposed. Further measurements on an experimental SWER line using two types of conductors were carried out. The results indicate that narrowband PLC implementation on SWER grids is feasible, and that conductors with similar size and material composition may have similar high frequency characteristics, regardless of the construction method used. The proposed earth path characterization method was verified by comparing measurements with simulations of frequency-dependent analytical, and constant parameter hybrid, per-unit SWER transmission line models.