Germán Cánovas Ambit

Prof. Dr. Germán Cánovas Ambit

Universidad de Murcia
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2021 in PeerJ
Verified
Journal Article
Open access
PDF file
Germán Cánovas AmbitGermán Cánovas Ambit
Germán Cánovas Ambit
JGJose Antonio Garcia-Vidal
Jose Antonio Garcia-Vidal
Rodrigo Martín San AgustínRodrigo Martín San Agustín
Rodrigo Martín San Agustín
ADAurelio Arenas Dalla-Vecchia
Aurelio Arenas Dalla-Vecchia
MSMariana Sánchez-Barbadora
Mariana Sánchez-Barbadora
FMFrancesc Medina-Mirapeix
Francesc Medina-Mirapeix
Background: Neck pain has a high annual incidence and decreases the cervical active range of motion (ROM). Clinicians use various methods to evaluate cervical range of motion (CROM) that some of them have also been proposed to give instant feedback. Accordingly, this study aimed to examine the validity and reliability of Veloflex (VF) to measure the CROM by comparison with the cervical range of motion (CROM) device, and to examine their test-retest reliability. Methods: Thirty-eight healthy and 20 symptomatic participants were evaluated. Cervical flexion-extension, side bending, and rotations were tested in two sessions, first by the CROM and VF and in the second only with the VF. To evaluate the concurrent validity and agreement between CROM and VF, Pearson correlation coefficient (r) and Bland–Altmann plots were used. Reliability were evaluated using intra-class correlation (ICC), standard error of measurement (SEM) and minimal detectable change (MDC). Results: CROM and VF showed excellent correlation for all movements (r > 0.960). Both devices provided small mean ‘bias’ (≤1.29%) in all movements regarding CROM measures. The intra-rater and inter-rater reliability of the VF was excellent (ICC > 0.98). SEMs ranging from 0.72% to 2.38% and the MDC ranging from 1.22° to 2.60° in all participants. The results support the validity and reliability of VF to measure CROM. For its use, with a basic training is enough to get reliable measurements.

2 November 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Rodrigo Martín San AgustínRodrigo Martín San Agustín
Rodrigo Martín San Agustín
JGJose Antonio Garcia-Vidal
Jose Antonio Garcia-Vidal
Germán Cánovas AmbitGermán Cánovas Ambit
Germán Cánovas Ambit
AAAurelio Arenas
Aurelio Arenas
MLManuel López-Nicolás
Manuel López-Nicolás
Francesc Medina-MirapeixFrancesc Medina-Mirapeix
Francesc Medina-Mirapeix
The aim of this study was to evaluate the validity of the Veloflex infrared dynamic angle-meter (Veloflex-IDA) and the intra- and inter-rater reliability when measuring the ranges of motion (ROMs) of the upper limb joints. Thirty-five healthy and 20 symptomatic participants were evaluated. Twelve upper limb movements were measured in two sessions with the Veloflex-IDA, which is a device composed of a camera that tracks the trajectory of retro-reflective markers. In addition, a goniometer was used in the first session to evaluate concurrent validity. Validity and agreement were evaluated by Pearson correlation coefficient (r) and Bland–Altmann plots. Intra- and inter-rater reliability were evaluated using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable change (MDC). Both instruments showed excellent correlation for all movements (r range from 0.992 to 0.999). The intra- and inter-rater reliability were excellent (ICC range from 0.95 to 0.99 and 0.90 to 0.98, respectively). Intra-rater reliability showed SEMs <1.38% and <5.19% and inter-rater reliability SEMs <2.26% and <5.22% for asymptomatic and symptomatic, respectively. Veloflex-IDA is a valid and reliable alternative to measure the upper limb joints’ ROM and it can be used in clinical practice and research after basic training.

22 August 2019 in Medicina
Verified
Journal Article
Open access
PDF file
Francesc Medina-MirapeixFrancesc Medina-Mirapeix
Francesc Medina-Mirapeix
Rodrigo Martín San AgustínRodrigo Martín San Agustín
Rodrigo Martín San Agustín
Germán Cánovas AmbitGermán Cánovas Ambit
Germán Cánovas Ambit
JGJose Antonio Garcia-Vidal
Jose Antonio Garcia-Vidal
MGMariano Gacto-Sánchez
Mariano Gacto-Sánchez
MEMaria P. Escolar-Reina
Maria P. Escolar-Reina
Background and Objectives: Within the clinical evaluation of multiple pathologies of the lower limb, the measurement of range of motion (ROM) of its joints is fundamental. To this end, there are various tools, from the goniometer as a reference to more recent devices such as inclinometry-based applications, photo capture applications, or motion capture systems. This study aimed to assess the validity, intra-rater, and inter-rater reliability of the VeloFlex system (VS), which is a new camera-based tool designed for tracking joint trajectories and measuring joint ROM. Materials and Methods: Thirty-five healthy volunteers (16 females; aged 18–61 years) participated in this study. All participants were assessed on two separate occasions, one week apart. During the first assessment session, measurements were obtained using a goniometer and the VS, whereas, in the second session, only the VS was used. In each assessment session, nine active movements were examined. For each movement, three trials were tested, and the mean of these three measures was used for analysis. To evaluate the concurrent validity and agreement, the Pearson correlation coefficient (r) and Bland-Altmann plots were used. Intra-rater and inter-rater reliability were evaluated using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable change (MDC). Results: Both devices showed excellent correlations for all movements (r ranged from 0.992 to 0.999). The intra-rater reliability of the VS was excellent (ICC ranged from 0.93 to 0.99), SEMs ranged from 0.53% to 2.61% and the MDC ranged from 0.68° to 3.26°. The inter-rater reliability of the VS was also excellent (ICC ranged from 0.88 to 0.98), SEMs ranged from 0.81% to 4.76% and the MDC ranged from 2.27° to 4.42°. Conclusions: The VS is a valid and reliable tool for the measurement of ROM of lower limb joints in healthy subjects.

19 October 2024 in Journal of Bodywork and Movement Therapies
Verified
Journal Article
Open access
ARAnais López Requena
Anais López Requena
AAAITOR BAÑO ALCARAZ
AITOR BAÑO ALCARAZ
PRPilar Escolar Reina
Pilar Escolar Reina
EGEdgar Ferrández Gómez
Edgar Ferrández Gómez
Germán Cánovas AmbitGermán Cánovas Ambit
Germán Cánovas Ambit
To compare the effectiveness of a combined treatment involving manual therapy and postural exercises in wind musicians with temporomandibular dysfunction (TMD). A randomized controlled clinical trial was conducted among a sample of TMD-affected wind-instrument musician students (NCT05893251), who were assigned to an experimental group (EG) or a control group (CG). Both groups underwent an active cervical postural treatment for 4 weeks, with the experimental group (EG) additionally receiving a cervical therapy protocol. Participants were assessed through the craniofacial pain and disability inventory (CF-PDI) test and maximum mouth opening (MMO). The treatment administered to the experimental group (EG) demonstrated higher efficacy compared to the control group (CG) in terms of MMO and CF-PDI scores (p < 0.05). A therapeutic program including manual therapy at a cervical level and a program of active postural exercises results to be more effective than solely performing postural exercises on wind musicians with DTM.

1 January 2024 in Enfermería Global
Verified
Journal Article
Open access
PDF file
NMNoelia Vivancos Marín
Noelia Vivancos Marín
Germán Cánovas AmbitGermán Cánovas Ambit
Germán Cánovas Ambit
JGJuan Carlos Sánchez García
Juan Carlos Sánchez García
ARAnais López Requena
Anais López Requena
JGJose Antonio Garcia-Vidal
Jose Antonio Garcia-Vidal
Introduction:There is a need to provide analgesia strategies that encourage and promote women's participation in decision-making at the time of delivery and relaxation techniques could be a complementary and/or alternative non-pharmacological analgesic method to the widely used epidural anaesthesia in standard labour care. Objective: The objective of this study is to analyze the obstetric effects of relaxation techniques on pain management during labour. Method: A systematic review is performed with critical reading of included studies. The search for studies was carried out in the main databases MEDLINE, Cochrane Library, Cuiden, LILACS and SciELO. Studies published in English or Spanish between 2015 and February 2021 were included. Eleven studies were included, six of which are systematic reviews and five are randomised clinical trials. The interventions analysed were relaxation techniques such as hypnosis, intradermal injection of sterile water, warm water immersion, massage, acupuncture, music therapy, aromatherapy, continuous support and mind-body practices like relaxing breathing, yoga and meditation, among others. Conclusion: The main conclusion of this study is that relaxation techniques may decrease the level of pain during labour, although the current scientific evidence is limited and the methodological quality varies from low to moderate. More randomised controlled trials are needed to support this research. Introducción: Existe la necesidad de proporcionar estrategias de analgesia que alienten y promuevan la participación de la mujer en la toma de decisiones en el momento del parto y las técnicas de relajación podrían ser un método analgésico no far-macológico complementario y/o alternativo a la anestesia epidural ampliamente utilizado. en la estándar atención del trabajo de parto. Objetivo: El objetivo de este estudio es analizar los efectos obstétricos de las técnicas de relajación en el manejo del dolor durante el parto. Método: Se realiza una revisión sistemática con lectura crítica de los estudios incluidos. La búsqueda de estudios se realizó en las principales bases de datos MEDLINE, Cochrane Library, Cuiden, LILACS y SciELO. Se incluyen estudios publicados en inglés o español entre 2015 y febrero de 2021. Se incluyen una vez estudios, seis de los cuales son revisados sistemáticamente y cinco son ensayos clínicos aleatorios. Las intervenciones analizadas fueron técnicas de relajación como hipnosis, inyección intradérmica de agua estéril, inmersión en agua tibia, masaje, acu-puntura, musicoterapia, aromaterapia, apoyo continuo y prácticas mente-cuerpo como respiración relajante, yoga y meditación, entre otras.Conclusión: La principal conclusión de este estudio es que las técnicas de relajación pueden disminuir el nivel de dolor durante el trabajo, aunque la evidencia científica actual es limitada y la calidad metodológica varía de baja a moderada. Se necesitan más ensayos controlados aleatorios para apoyar esta investigación.

26 June 2025 in Journal Physiotherapy Interventions
Verified
Journal Article
Open access
PDF file
FFFacultad de Medicina Departamento de Fisioterapia
Facultad de Medicina Departamento de Fisioterapia
Germán Cánovas AmbitGermán Cánovas Ambit
Germán Cánovas Ambit
JGJose Antonio Garcia-Vidal
Jose Antonio Garcia-Vidal
Antecedentes: Las técnicas invasivas, como la punción seca y la electrólisis percutánea, requieren una formación específica que combine precisión técnica y seguridad. El uso de metodologías docentes innovadoras podría mejorar la experiencia de aprendizaje y la preparación del fisioterapeuta en este campo. Métodos: El objetivo de este estudio fue describir la percepción del alumnado sobre la calidad y utilidad de un curso de técnicas invasivas estructurado en torno a metodologías innovadoras como la simulación, la práctica guiada y el uso de modelos anatómicos. Se llevó a cabo un estudio descriptivo de tipo transversal, mediante la recogida de datos a través de una encuesta estructurada. Se evaluaron variables como la satisfacción general, la utilidad percibida de los recursos didácticos, la confianza en la ejecución de la técnica y las preferencias de aprendizaje. Resultados: La mayoría del alumnado valoró positivamente el curso, destacando la utilidad de las herramientas de innovación docente. Conclusiones: La innovación docente basada en simulación y práctica intensiva mejora la percepción de aprendizaje en fisioterapia invasiva. Se recomienda profundizar en el desarrollo de itinerarios formativos adaptados y sostenibles que integren estas metodologías de forma estructurada.