Radu Rosu

Dr. Radu Rosu


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2019 in Medicina
Verified
Journal Article
Open access
PDF file
SISabina Istratoaie
Sabina Istratoaie
RRRadu Rosu
Radu Rosu
Gabriel CismaruGabriel Cismaru
Gabriel Cismaru
Stefan Cristian VesaStefan Cristian Vesa
Stefan Cristian Vesa
MPMihai Puiu
Mihai Puiu
ABAnca Dana Buzoianu
Anca Dana Buzoianu
Background and Objectives: Prior studies have identified a number of predictors for Atrial fibrillation (AF) ablation success, including comorbidities, the type of AF, and left atrial (LA) size. Ectopic foci in the initiation of paroxysmal AF are frequently found in pulmonary veins. Our aim was to assess how pulmonary vein anatomy influences the recurrence of atrial fibrillation after radiofrequency catheter ablation. Materials and Methods: Eighty patients diagnosed with paroxysmal or persistent AF underwent radiofrequency catheter ablation (RFCA) between November 2016 and December 2017. All of these patients underwent computed tomography before AF ablation. PV anatomy was classified according to the presence of common PVs or accessory PVs. Several clinical and imagistic parameters were recorded. After hospital discharge, all patients were scheduled for check-up in an outpatient clinic at 3, 6, 9, and 12 months after RFCA to detect AF recurrence. Results: A total of 80 consecutive patients, aged 53.8 ± 9.6 years, 54 (67.5%) men and 26 (32.5%) women were enrolled. The majority of patients had paroxysmal AF 53 (66.3%). Regular PV anatomy (2 left PVs, 2 right PVs) was identified in 59 patients (73.7%), a left common trunk (LCT) was detected in 15 patients (18.7%), an accessory right middle pulmonary vein (RMPV) was found in 5 patients (6.25%) and one patient presented both an LCT and an RMPV. The median follow-up duration was 14 (12; 15) months. Sinus rhythm was maintained in 50 (62.5%) patients. Age, gender, antiarrhythmic drugs, and the presence of cardiac comorbidities were not predictive of AF recurrence. The diagnosis of persistent AF before RFCA was more closely associated with an increase in recurrent AF after RFCA than after paroxysmal AF (p = 0.01). Longer procedure times (>265 min) were associated with AF recurrence (p = 0.04). Patients with an LA volume index of over 48.5 (mL/m2) were more likely to present AF recurrence (p = 0.006). Multivariate analysis of recurrence risk showed that only the larger LA volume index and variant PV anatomy were independently associated with AF recurrence. Conclusion: The study demonstrated that an increased volume of the left atrium was the most important predictive factor for the risk of AF recurrence after catheter ablation. Variant anatomy of PV was the only other independent predictive factor associated with a higher rate of AF recurrence.

1 March 2016 in Medical Ultrasonography
Verified
Journal Article
Closed access
GGGabriel Guşetu
Gabriel Guşetu
DPDana Pop
Dana Pop
CPCristina Pamfil
Cristina Pamfil
RBRaluca Bǎlaj
Raluca Bǎlaj
LMLucian Mureşan
Lucian Mureşan
SRSimona Rednic
Simona Rednic
Aims: Myocardial damage is frequent and often silent in systemic lupus erythematosus (SLE). The aim of the study was to determine the prevalence of myocardial damage by novel ultrasound techniques and to systematically assess the relationship between subclinical cardiac dysfunction and SLE-related clinical parameters. Material and methods: Seventy-five consecutive SLE patients without evidence of cardiac disease and seventy-three controls underwent standard transthoracic echocardiography using classical and novel ultrasound techniques: tissue Doppler imaging and speckle tracking echocardiography. Patient characteristics, cumulative organ damage and laboratory data were retrieved by medical chart review. Results: Within the cohort, 89.3% of the patients were female; mean±SD age and median (IQR) disease duration were 43.2±12.5 years and 8.03(6.3) years, respectively. SLE patients exhibited a significant decrement in endocardial longitudinal strain (-18.4% vs 19.3%, p=0.001) compared with controls. Diastolic dysfunction was detected in 34 (45.3%) of SLE patients. Major determinants of systolic and diastolic dysfunction were hypertension (p=0.023 and p<0.001, respectively), associated antiphospholipid syndrome (APS) (p<0.001 and p<0.001, respectively), cumulative damage accrual (p<0.001 and p=0.003, respectively), and disease duration (p=0.03 and p<0.001, respectively). Notably, anti-Ro antibodies were present in 37% of the SLE patients who had better systolic longitudinal performance. Neither disease activity, nor specific organ involvement, were associated with myocardial impairment. Conclusion: Systolic longitudinal and diastolic performance impairments are frequent findings in SLE patients without overt cardiovascular disease. Cumulative organ damage, disease duration, APS, and hypertension are major determinants for early heart involvement in SLE patients.

13 August 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
SISabina Istratoaie
Sabina Istratoaie
Stefan Cristian VesaStefan Cristian Vesa
Stefan Cristian Vesa
Gabriel CismaruGabriel Cismaru
Gabriel Cismaru
DPDana Pop
Dana Pop
RRRadu Rosu
Radu Rosu
ABAnca Dana Buzoianu
Anca Dana Buzoianu
Atrial fibrillation (AF) recurrence after radiofrequency catheter ablation (RFCA) remains a challenging issue. This study aims to explore the left atrial appendage function by transesophageal echocardiography (TEE) and assess its value in predicting AF recurrence following RFCA in paroxysmal AF patients. Eighty-one patients with paroxysmal AF that underwent RFCA were recruited. TEE was performed before ablation with the assessment of left atrial appendage emptying flow velocity (LAAeV). AF recurrence occurred in 24 patients (29.6%) within 12 months after RFCA. The left atrium diameter (LAD) and left atrium volume index (LAVI) were both significantly higher in the recurrence group compared to the non-recurrence group, while the LAAeV was significantly lower in the recurrence group. LAD, LAVi and LAAeV were univariately significant risk factors for AF recurrence after ablation. Based on receiver operating curve (ROC), LAAeV < 40.5 cm/s, LAVi > 40.5 mL and LAD > 41 mm were identified as cut-off values for predicting AF recurrence. In multivariate regression analysis LAAeV < 40.5 cm/s (HR 8.194, 95% CI 2.980–22.530, p < 0.001) was identified as the only statistically significant independent predictor of AF recurrence, as the statistical significance threshold was not achieved for LAVI > 40.5 mL and LAD > 41 mm (p = 0.319; p = 0.507, respectively). A low LAAeV was the only important independent predictor of AF recurrence within 1 year after first RFCA.

1 March 2021 in CardioVascular Journal of Africa
Verified
Journal Article
Closed access
GSGelu Simu
Gelu Simu
RRRadu Rosu
Radu Rosu
GCGabriel Cismaru
Gabriel Cismaru
MPMihai Puiu
Mihai Puiu
GGGabriel Gusetu
Gabriel Gusetu
DPDana Pop
Dana Pop
Cardiac electronic implantable devices (CIEDs) have the ability to monitor, store and interpret complex arrhythmias, which has generated a new arrhythmic entity: atrial high-rate episodes (AHRE). AHRE are atrial tachyarrhythmias, detected only by CIEDs. They are widely considered a precursor to atrial fibrillation (AF) but can also be represented by other kinds of supraventricular arrhythmias such as atrial flutter or atrial tachycardia. CIED-detected AHRE are associated with an increased risk of stroke, but the risk is significantly lower than the stroke risk of clinical AF. Moreover, there seems to be no temporal correlation between AHRE and thromboembolic events. Because of the current gaps in evidence, the appropriate management of this arrythmia can be challenging. In this review we take into account the epidemiology behind AHRE, predictive factors, clinical impact and management of this arrhythmia.

2 May 2019 in Medical Ultrasonography
Verified
Journal Article
Closed access
PDF file
RRRadu Rosu
Radu Rosu
Gabriel CismaruGabriel Cismaru
Gabriel Cismaru
LMLucian Muresan
Lucian Muresan
MPMihai Puiu
Mihai Puiu
GGGabriel Gusetu
Gabriel Gusetu
DZDumitru Zdrenghea
Dumitru Zdrenghea
The key to a successful catheterization of the left heart chambers is the safe transseptal puncture. Intracardiac echocardiography (ICE) is an attractive tool used in cardiac catheterization and electrophysiology labs to provide detailed images thatcan facilitate transseptal puncture. ICE permits a direct visualization of the endocardium and precisely locates the needle and the sheath against the interatrial septum. Two different ICE catheters are available: a phased array and a mechanical transducer, both being currently used in clinical practice. This paper describes the technique used for guiding transseptal puncture with ICE. Due to its advantages, ICE has currently become an important tool used to maximize the safety of the transseptal puncture and increase efficacy of interventional cardiology procedures.

13 December 2004 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
MFMarjaneh Fatemi
Marjaneh Fatemi
JMJacques Mansourati
Jacques Mansourati
RRRadu Rosu
Radu Rosu
JBJean‐Jacques Blanc
Jean‐Jacques Blanc