Background: Microvascular angina is a common clinical entity, with about a three-fold higher frequency in women. The pathogenesis of microvascular angina has not been much studied, but inflammation and endothelial dysfunction have been incriminated as the main mechanisms of this disease. Methoss: Our purpose was to analyze whether certain inflammatory markers, i.e., interleukin 6 (IL-6) and endothelin 1 (ET-1), can play a role in the diagnosis of microvascular angina in women. Results: Ninety women with ischemic heart disease were divided into two groups, based on their affliction with either microvascular or macrovascular disease. In general, the levels of IL6 and ET1 were similar between the two groups. Analyzing these marker levels according to the number of coronary lesions, we obtained an increased IL6 value that was similar for patients with microvascular angina, one-vessel, and two-vessel coronary disease, but significantly lower than in women with three-vessel coronary lesions. Also, in microvascular angina, IL6 level was correlated with the NYHA IV functional class. Unexpectedly, the level of ET1 was correlated with left ventricular systolic dysfunction. Conclusions: In women with an increased suspicion of microvascular angina, in whom microvascular dysfunction cannot be tested invasively, IL-6 level, unlike the ET-1 level, might be considered a diagnostic marker of this disease.
The key to a successful catheterization of the left heart chambers is the safe transseptal puncture. Intracardiac echocardiography (ICE) is an attractive tool used in cardiac catheterization and electrophysiology labs to provide detailed images thatcan facilitate transseptal puncture. ICE permits a direct visualization of the endocardium and precisely locates the needle and the sheath against the interatrial septum. Two different ICE catheters are available: a phased array and a mechanical transducer, both being currently used in clinical practice. This paper describes the technique used for guiding transseptal puncture with ICE. Due to its advantages, ICE has currently become an important tool used to maximize the safety of the transseptal puncture and increase efficacy of interventional cardiology procedures.
Aims: Intracardiac echocardiography (ICE) is a relatively young technique used during complex electrophysiology proce-dures, such as atrial fibrillation (AF) ablation. The aim of this study was to assess whether the use of ICE modifies the radia-tion exposure at the beginning of the learning curve in AF ablation. Materials and methods: In this retrospective study, 52 patients, in which catheter ablation for paroxysmal or persistent AF was performed, were included. For 26 patients we used ICE guidance together with fluoroscopy, whereas for the remaining 26 patients we used fluoroscopy alone, all supported by electroanatomical mapping. We compared total procedure time and radiation exposure, including fluoroscopy dose and time between the two groups and along the learning curve. Results: Most of the patients included were suffering from paroxysmal AF (40, 76%), pulmonary vein isolation being performed in all patients, without secondary ablation sites. The use of ICE was associated with a lower fluoroscopy dose (11839.60±6100.6 vs. 16260.43±8264.5 mGy, p=0.041) and time (28.00±12.5 vs. 42.93±12.7 minutes, p=0.001), whereas the mean procedure time was similar between the two groups (181.54±50.3 vs 197.31±49.8 minutes, p=0.348). Radiation exposure was lower in the last 9 months compared to the first 9 months of the study (p<0.01), decreasing gradually along the learning curve. Conclusions: The use of ICE lowers radiation exposure in AF catheter ablation from the beginning of the learning curve, without any difference in terms of acute safety or efficacy. Aware-ness towards closest to zero radiation exposure during electrophysiology procedures should increase in order to achieve better protection for both patient and medical staff.
Chronic obstructive pulmonary disease (COPD) is a leading cause of morbidity and mortality worldwide. Smoking remains the most important risk factor, but occupational exposures may play an essential role as well. Firefighters are among occupations regularly exposed to a variety of irritative inhalational products, and they may be expected to develop respiratory health problems because of such an occupational exposure. To better understand and characterize this relationship, we performed an extensive search of the scientific literature, and we identified two major research areas: firefighters exposed to wildland fire smoke and firefighters involved in the World Trade Centre disaster-related operations. Most of the studies did not report a significant increase in COPD diagnosis in firefighters. An accelerated rate of decline in lung function was seen, a short time after major exposure events. This is the reason for an increased rate of exacerbations observed in individuals already diagnosed with obstructive respiratory disorders. A limited number of studies not covering these specific circumstances of exposure were found. They reported long-term morbidity and mortality data, and the results are controversial. Major confounding factors for most of the studies were the “healthy worker effect” and the lack of useful data regarding smoking habits. Efforts should be made in the future to better characterize specific biomarkers for the progression of COPD; to establish exposure limits; and to implement preventive strategies like rotation of workers, smoking cessation programs, and long-term monitoring programs for respiratory disorders.
Background: The aim of our study was to assess the real life cardiac resynchronization therapy (CRT) fusion left ventricular (LV) only pacing in patients with normal AV conduction (NAVc) without right ventricular (RV) lead. Methods: Consecutive NAVc patients with CRT indication were implanted with a right atrium RA/LV DDD pacing system. Complete follow-up at 1, 3 and every 6 months thereafter included echocardiography and stress testing. Results: We analysed 55 patients (62 ± 11 years). All patients were responders with significant LV reverse remodelling (LV end-diastolic volume 193.7 ± 81 vs. 243.2 ± 82 mL at baseline, p < 0.002) and increased LV ejection fraction (38 ± 7.9% vs. 27 ± 5.2% at baseline, p < 0.001). Mitral regurgitation decreased in 38 patients (69%). During follow-up (35 ± 18 months), 20 patients (36%) needed reprogramming sensed/paced AV delay or maximum tracking rate (MTR) because of inadequate or lost LV capture at exercise test; personalized programming to achieve up to 100% fusion pacing was used in all patients. One patient developed Mobitz II second degree AV block and triple chamber CRT-P upgrade was performed; defibrillator upgrade was not necessary. Conclusions: LV only pacing CRT-P without RV lead showed a positive outcome in carefully selected patients.
Background and aim: Bradyarrhythmias cause a low cerebral blood flow with secondary neuronal ischemia and cognitive dysfunction. This study aims to assess the effect of cardiac pacemaker implantation (PI) on the cognitive function and inflammatory markers (TNF alpha, IL1β). Material and method: We conducted a prospective observational study on a number of 31 patients with symptomatic bradyarrhythmias. We performed the cognitive function assessment by two tests (Mini-Mental State Examination and Trail Making Test A), cardiac output assessment (echocardiographic), and determination of IL 1β and TNF alpha serum concentrations before pacemaker implantation and after an average period of 42 days from pacemaker implantation.Results: After pacemaker implantation we observed an increase in the cardiac index by 0.71 L/min/m2 (p < 0.001) and a better scoring in cognitive performance; the mean MMSE score increased by two points (p < 0.001), and Trail Making Test A had an improvement of 16 s (p < 0.001). Regarding the inflammatory markers, a significant decrease in IL-1β with 8.6 pg/mL (p = 0.049) after pacemaker implantation was observed. Additionally, we found statistically significant correlations between IL1β and TNF alpha (positive correlation, p = 0.005), between the MMSE and cardiac index (p < 0.001), between the Trail Making Test and cardiac index (p = 0.001), and between the MMSE and Trail Making Test (p = 0.003). Conclusions: Our findings suggest that cardiac pacemaker implantation was associated with improved cognitive function—possibly related to an increased cardiac output and with adecreased serum IL1β concentration in subjects with symptomatic bradycardia.