jorge Castro-Ramos

Dr. jorge Castro-Ramos

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
Jose L. Flores-GuerreroJose L. Flores-Guerrero
Jose L. Flores-Guerrero
AMAaron Munoz
Aaron Munoz
Freddy Narea JimenezFreddy Narea Jimenez
Freddy Narea Jimenez
RPRicardo Perez-Fuentes
Ricardo Perez-Fuentes
ETEnrique Torres-Rasgado
Enrique Torres-Rasgado
JCjorge Castro-Ramos
jorge Castro-Ramos
Urinary albumin excretion remains the key biomarker to detect renal complications in type 2 diabetes. As diabetes epidemy increases, particularly in low-income countries, efficient and low-cost methods to measure urinary albumin are needed. In this pilot study, we evaluated the performance of Raman spectroscopy in the assessment of urinary albumin in patients with type 2 diabetes. The spectral Raman analysis of albumin was performed using artificial urine, at five concentrations of albumin and 24 h collection urine samples from ten patients with Type 2 Diabetes. The spectra were obtained after removing the background fluorescence and fitting Gaussian curves to spectral regions containing features of such metabolites. In the samples from patients with type 2 diabetes, we identified the presence of albumin in the peaks of the spectrum located at 663.07, 993.43, 1021.43, 1235.28, 1429.91 and 1633.91 cm−1. In artificial urine, there was an increase in the intensity of the Raman signal at 1450 cm−1, which corresponds to the increment of the concentrations of albumin. The highest concentration of albumin was located at 1630 cm−1. The capability of Raman spectroscopy for detection of small concentrations of urinary albumin suggests the feasibility of this method for the screening of type 2 diabetes renal complications.

1 August 2021 in Food Chemistry
Verified
Journal Article
Closed access
NVNaara Gonzalez Viveros
Naara Gonzalez Viveros
PGPilar Gómez Gil
Pilar Gómez Gil
JCjorge Castro-Ramos
jorge Castro-Ramos
HCHéctor Hugo Cerecedo-Núñez
Héctor Hugo Cerecedo-Núñez

9 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
RJRicardo Jimenez
Ricardo Jimenez
Mario MorenoMario Moreno
Mario Moreno
Alfonso TorresAlfonso Torres
Alfonso Torres
AMAlfredo Morales
Alfredo Morales
Arturo PonceArturo Ponce
Arturo Ponce
ECEduardo Cano
Eduardo Cano
This work reports the development of arrays of infrared sensors (microbolometers) using a hydrogenated polymorphous silicon–germanium alloy (pm-SixGe1-x:H). Basically, polymorphous semiconductors consist of an amorphous semiconductor matrix with embedded nanocrystals of about 2–3 nm. The pm-SixGe1-x:H alloy studied has a high temperature coefficient of resistance (TCR) of 4.08%/K and conductivity of 1.5 × 10−5 S∙cm−1. Deposition of thermosensing film was made by plasma-enhanced chemical vapor deposition (PECVD) at 200 °C, while the area of the devices is 50 × 50 μm2 with a fill factor of 81%. Finally, an array of 19 × 20 microbolometers was packaged for electrical characterization. Voltage responsivity values were obtained in the range of 4 × 104 V/W and detectivity around 2 × 107 cm∙Hz1/2/W with a polarization current of 70 μA at a chopper frequency of 30 Hz. A minimum value of 2 × 10−10 W/Hz1/2 noise equivalent power was obtained at room temperature. In addition, it was found that all the tested devices responded to incident infrared radiation, proving that the structure and mechanical stability are excellent.

1 October 1998 in Applied Optics
Verified
Journal Article
Closed access
PDF file
ACAlberto Cordero-Dávila
Alberto Cordero-Dávila
JCjorge Castro-Ramos
jorge Castro-Ramos
The position and dimensions of the circle of least confusion (CLC) on axis for a lensless Schmidt camera telescope operating at F 0.82 are calculated. The camera is to be used in the fluorescence detector of the Pierre Auger Observatory. Our analysis was developed for an aspherical mirror for any on-axis position of the point light source. Our technique uses the intersection of the marginal ray from one side of the aperture with the caustic produced by the intermediate rays from the opposite side of the aperture to locate the CLC.

20 November 2004 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JCjorge Castro-Ramos
jorge Castro-Ramos
OPOscar de Ita Prieto
Oscar de Ita Prieto
GSGilberto Silva-Ortigoza
Gilberto Silva-Ortigoza
We use geometrical optics to compute, in an exact way and by using the third-order approximation, the disk of least confusion (DLC) or the best image produced by a conic reflector when the point source is located at any position on the optical axis. In the approximate case we obtain analytical formulas to compute the DLC. Furthermore, we apply our equations to particular examples to compare the exact and approximate results.

21 January 2022 in Journal of Raman Spectroscopy
Verified
Journal Article
Closed access
PDF file
CVCaroleny Villalba‐Hernández
Caroleny Villalba‐Hernández
MMMaría de los Angeles Moyaho-Bernal
María de los Angeles Moyaho-Bernal
Freddy Narea JimenezFreddy Narea Jimenez
Freddy Narea Jimenez
HCHéctor Nahum Chavarría-Lizárraga
Héctor Nahum Chavarría-Lizárraga
MGMaría Cecilia Galeazzi‐Minutti
María Cecilia Galeazzi‐Minutti
JCjorge Castro-Ramos
jorge Castro-Ramos