Joëlle Goyette Pernot

Prof. Joëlle Goyette Pernot

HES-SO University of Applied Sciences and Arts Western Switzerland
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Building and Environment
Verified
Journal Article
Open access
SYShen Yang
Shen Yang
JPJoëlle Goyette Pernot
Joëlle Goyette Pernot
CJCorinne Hager Jörin
Corinne Hager Jörin
HNHélène Niculita-Hirzel
Hélène Niculita-Hirzel
VPVincent Perret
Vincent Perret
DLDusan Licina
Dusan Licina

19 March 2020 in Indoor Air
Verified
Journal Article
Open access
PDF file
SYShen Yang
Shen Yang
VPVincent PERRET
Vincent PERRET
CJCorinne Hager Jörin
Corinne Hager Jörin
HNHélène Niculita-Hirzel
Hélène Niculita-Hirzel
JPJoëlle Goyette Pernot
Joëlle Goyette Pernot
Dusan LicinaDusan Licina
Dusan Licina
Exposure to elevated levels of certain volatile organic compounds (VOCs) in households has been linked to deleterious health effects. This study presents the first large‐scale investigation of VOC levels in 169 energy‐efficient dwellings in Switzerland. Through a combination of physical measurements and questionnaire surveys, we investigated the influence of diverse building characteristics on indoor VOCs. Among 74 detected compounds, carbonyls, alkanes and alkenes were the most abundant. Median concentration levels of formaldehyde (14 μg/m3), TVOC (212 μg/m3), benzene (< 0.1 μg/m3) and toluene (22 μg/m3) were below the upper exposure limits. Nonetheless, 90% and 50% of dwellings exceeded the chronic exposure limits for formaldehyde (9 μg/m3) and TVOC (200 μg/m3) respectively. There was a strong positive correlation among VOCs that likely originated from common sources. Dwellings built between 1950s and 1990s, and especially those with attached garages had higher TVOC concentrations. Interior thermal retrofit of dwellings and absence of mechanical ventilation system were associated with elevated levels of formaldehyde, aromatics and alkanes. Overall, energy‐renovated homes had higher levels of certain VOCs compared to newly built homes. The results suggest that energy‐efficiency measures in dwellings should be accompanied with actions to mitigate VOC exposures as to avoid adverse health outcomes.

7 January 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
JRJoan Frédéric Rey
Joan Frédéric Rey
SGStéphane Goyette
Stéphane Goyette
MGMauro Gandolla
Mauro Gandolla
MPMartha Palacios
Martha Palacios
FBFabio Barazza
Fabio Barazza
JPJoëlle Goyette Pernot
Joëlle Goyette Pernot
Radon is a natural and radioactive gas that can accumulate in indoor environments. Indoor radon concentration (IRC) is influenced, among other factors, by meteorology, which is the subject of this paper. Weather parameters impact indoor radon levels and have already been investigated, but rarely in Switzerland. Moreover, there is a strong need for a better understanding of the radon behaviour inside buildings in Switzerland for public health concerns as Switzerland is a radon prone area. Based on long-term, continuous, and hourly radon measurements, radon distributions classified according to different weather event definitions were investigated and then compared at three different study sites in Western Switzerland. Outdoor temperature influences the most indoor radon, and it is globally anti-correlated. Wind influences indoor radon, but it strongly depends on intensity, direction, and building characteristics. Precipitation influences periodically indoor radon levels relatively to their intensity. Atmospheric pressure and relative humidity do not seem to be huge determinants on IRC. Our results are in line with previous findings and provide a vivid example in Western Switzerland. This paper underlines the different influence complexities of radon, and the need to communicate about it within the broader public and with construction professionals, to raise awareness.

4 December 2019 in Atmosphere
Verified
Journal Article
Open access
PDF file
SYShen Yang
Shen Yang
JPJoëlle Goyette Pernot
Joëlle Goyette Pernot
CJCorinne Hager Jörin
Corinne Hager Jörin
HNHélène Niculita-Hirzel
Hélène Niculita-Hirzel
VPVincent PERRET
Vincent PERRET
Dusan LicinaDusan Licina
Dusan Licina
As part of more stringent energy targets in Switzerland, we witness the appearance of new green-certified dwellings while many existing dwellings have undergone energy efficiency measures. These measures have led to reduced energy consumption, but rarely consider their impact on indoor air quality. Consequently, such energy renovation actions can lead to an accumulation of radon in dwellings located in radon-prone areas at doses that can affect human health. This study compared the radon levels over 650 energy-efficient dwellings in western Switzerland between green-certified (Minergie) and energy-renovated dwellings, and analyzed the building characteristics responsible of this accumulation. We found that the newly green-certified dwellings had significantly lower radon level than energy-renovated, which were green- and non-green-certified houses (geometric mean 52, 87, and 105 Bq/m3, respectively). The new dwellings with integrated mechanical ventilation exhibited lower radon concentrations. Thermal retrofitting of windows, roofs, exterior walls, and floors were associated with a higher radon level. Compared to radon measurements prior to energy renovation, we found a 20% increase in radon levels. The results highlight the need to consider indoor air quality when addressing energy savings to avoid compromising occupants’ health, and are useful for enhancing the ventilation design and energy renovation procedures in dwellings.

HNHélène Niculita-Hirzel
Hélène Niculita-Hirzel
SYShen Yang
Shen Yang
CJCorinne Hager Jörin
Corinne Hager Jörin
VPVincent PERRET
Vincent PERRET
Dusan LicinaDusan Licina
Dusan Licina
JPJoëlle Goyette Pernot
Joëlle Goyette Pernot
The presence of growing fungi in the indoor environment has been associated with the development of respiratory problems such as asthma or allergic rhinitis, as well as the worsening of respiratory pathologies. Their proliferation indoors could be a result of water leakage or inadequate ventilation. Although the factors promoting mould growth have been widely investigated in traditional dwellings, little work has been done in energy efficient dwellings. Here, the effectiveness of ventilation type, i.e., natural or mechanical, in influencing mould development was estimated in 44 recent and 105 retrofitted energy efficient dwellings. Fungi growing on surfaces were investigated in the dwellings situated in rural, peri-urban, and urban regions of Switzerland. The presence of these fungi was also investigated in bedroom settled dust. Information on building characteristics and owners’ lifestyle were collected. Significant associations were found with the level of urbanisation, the location of mouldy area in dwellings, and the diversity of fungal taxa. Dwellings in peri-urban zones showed the most frequent fungal contamination in the owners’ bedroom and the highest diversity of fungal genera among dwellings. While the urbanisation level or the ventilation type favoured no specific genus, we found marked disparities in the diversity of fungi growing on surfaces in naturally ventilated versus mechanically ventilated dwellings. Aspergillus, in particular, was a frequent surface contaminant in bedrooms with natural ventilation, but not in those mechanically ventilated. We observed a strong association between fungal growth on surfaces and the number of fungal particles counted in the settled dust of owners’ bedrooms. These results demonstrate the importance of ventilation systems in energy efficient dwellings in controlling fungal proliferation in living areas.

8 January 2024 in Building and Environment
Verified
Journal Article
Open access
JRJoan Frédéric Rey
Joan Frédéric Rey
NMNicolas Meisser
Nicolas Meisser
Dusan LicinaDusan Licina
Dusan Licina
JPJoëlle Goyette Pernot
Joëlle Goyette Pernot