Dusan Licina

Prof. Dr. Dusan Licina

School for Architecture, Civil, and Environmental Engineering, École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Building and Environment
Verified
Journal Article
Open access
IDIngrid Demanega
Ingrid Demanega
IMIgor Mujan
Igor Mujan
BSBrett Singer
Brett Singer
AAAleksandar S. Anđelković
Aleksandar S. Anđelković
Francesco BabichFrancesco Babich
Francesco Babich
Dusan LicinaDusan Licina
Dusan Licina

1 May 2014 in Building and Environment
Verified
Journal Article
Closed access
Dusan LicinaDusan Licina
Dusan Licina
JPJovan Pantelic
Jovan Pantelic
AMArsen Melikov
Arsen Melikov
CSChandra Sekhar
Chandra Sekhar
Kwok Wai ThamKwok Wai Tham
Kwok Wai Tham

23 December 2016 in Indoor Air
Verified
Journal Article
Closed access
PDF file
Dusan LicinaDusan Licina
Dusan Licina
YTY. Tian
Y. Tian
WNW. W. Nazaroff
W. W. Nazaroff

24 May 2014 in Indoor Air
Verified
Journal Article
Closed access
PDF file
Dusan LicinaDusan Licina
Dusan Licina
AMA. Melikov
A. Melikov
CSC. Sekhar
C. Sekhar
Kwok Wai ThamKwok Wai Tham
Kwok Wai Tham
This study investigates the interaction between the human convective boundary layer (CBL) and uniform airflow with different velocity and from different directions. Human body is resembled by a thermal manikin with complex body shape and surface temperature distribution as the skin temperature of an average person. Particle image velocimetry (PIV) and pseudocolor visualization (PCV) are applied to identify the flow around the manikin's body. The findings show that the direction and magnitude of the surrounding airflows considerably influence the airflow distribution around the human body. Downward flow with velocity of 0.175 m/s does not influence the convective flow in the breathing zone, while flow at 0.30 m/s collides with the CBL at the nose level reducing the peak velocity from 0.185 to 0.10 m/s. Transverse horizontal flow disturbs the CBL at the breathing zone even at 0.175 m/s. A sitting manikin exposed to airflow from below with velocity of 0.30 and 0.425 m/s assisting the CBL reduces the peak velocity in the breathing zone and changes the flow pattern around the body, compared to the assisting flow of 0.175 m/s or quiescent conditions. In this case, the airflow interaction is strongly affected by the presence of the chair.

18 May 2020 in Indoor Air
Verified
Journal Article
Closed access
PDF file
GBGabriel Bekö
Gabriel Bekö
PWPawel Wargocki
Pawel Wargocki
NWNijing Wang
Nijing Wang
MLMengze Li
Mengze Li
CWCharles J. Weschler
Charles J. Weschler
JWJonathan Williams
Jonathan Williams

14 February 2018 in Indoor Air
Verified
Journal Article
Closed access
PDF file
Dusan LicinaDusan Licina
Dusan Licina
WNW. W. Nazaroff
W. W. Nazaroff