Vladimir N. Khmelev

Prof. Vladimir N. Khmelev


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Ultrasonics
Verified
Journal Article
Closed access
VKVladimir N. Khmelev
Vladimir N. Khmelev
ASAndrey Shalunov
Andrey Shalunov
VNViktor Aleksandrovich Nesterov
Viktor Aleksandrovich Nesterov

1 April 2011 in Journal of Zhejiang University-SCIENCE A
Verified
Journal Article
Closed access
PDF file
VKVladimir N. Khmelev
Vladimir N. Khmelev
ASAndrey Shalunov
Andrey Shalunov
RBRoman V. Barsukov
Roman V. Barsukov
DADenis S. Abramenko
Denis S. Abramenko
ALAndrey N. Lebedev
Andrey N. Lebedev
The aim of this investigation was to define the effectiveness of non-contact drying using ultrasonic vibrations. Disk radiators were used for carrying out experiments, and a special drying chamber was designed to provide resonant amplification of ultrasonic vibrations (from 130 to 150 dB). Drying of ginseng and other vegetables demonstrated that the application of ultrasonic vibrations reduced power inputs by 20% in comparison with convective drying. It also led to a decrease of 6% in final moisture content, if the duration of drying was constant. The level of intensification of ultrasonic drying was high (up to 50 g for 1 kg of drying material), which helped to lower the temperature of the drying agent and improve the quality of the dried products.

24 September 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
VKVladimir N. Khmelev
Vladimir N. Khmelev
ASAndrey Shalunov
Andrey Shalunov
VNViktor Aleksandrovich Nesterov
Viktor Aleksandrovich Nesterov
The method for increasing the separation efficiency of particles smaller than 2.5 micrometers by combined ultrasonic agglomeration and swirling flow technique is proposed in the article. The swirling flow creates areas with an increased concentration of particles on the outer radius of the vortex. The ultrasonic exposure on these areas leads to more efficient agglomeration and the formation of agglomerates of many times larger than the original particles. The resulting agglomerates are easily separated from the gas flow. The design of the agglomerator was developed. The vortex velocity is determined, at which ultrasonic exposure on the swirling flow increases the average particle size d32 = 2.5 micrometer to 4.5 times. The ultrasonic exposure on a rectilinear flow can increase the particle size no more than 1.6 times for comparison. The proposed method is compared with inertial gas clearing in a cyclone. It was found that the proposed combined method allows increasing the cleaning efficiency from 46% to 85% at ultrasonic exposure on the swirling flow in the agglomerator and cyclone.

6 October 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
VKVladimir N. Khmelev
Vladimir N. Khmelev
ASAndrey Shalunov
Andrey Shalunov
VNViktor Aleksandrovich Nesterov
Viktor Aleksandrovich Nesterov
A new design of a high-frequency piezoelectric transducer with a power from 70 to 1800 W (designed for radiation into liquids and gases of ultrasonic (US) vibrations in the frequency range of $30,\ldots,100$ kHz) is proposed. It is based on the principle of summation on a diametrically vibrating summing plate of vibrations of radially mounted Langevin transducers. The method of their design was created and the optimal design dimensions of the transducers were established. This made it possible to manufacture and research practical designs of transducers at frequencies of 30 and 90 kHz. The created transducers together with disk radiators allowed creating US vibrations of 155 dB in the gas at a frequency of 31.67 kHz and 151 dB at a frequency of 92.82 kHz. In this case, the power of the generated vibrations was limited by existing radiators of disk form and a small wave resistance of gas. As a result, the transducers provided radiation up to 1800 W at a frequency of 31.67 kHz and up to 250 W at a frequency of 92.82 kHz of acoustic power. The transducer can be used at processing of liquids, such as dispersion, emulsification, extraction, degassing of liquids, sterilization, and homogenization. The transducer can be used for agglomeration of suspended dispersed particles in gases, drying of various materials, and liquid spraying when exposed to gases. There are no restrictions on the number of simultaneously operating transducers. However, the overall dimensions exclude tight packaging. Therefore, its use in any array with a wavelength-oriented separation is not possible.

13 May 2020 in International Journal of Environmental Science and Technology
Verified
Journal Article
Closed access
PDF file
VKVladimir N. Khmelev
Vladimir N. Khmelev
ASAndrey Shalunov
Andrey Shalunov
VNViktor Aleksandrovich Nesterov
Viktor Aleksandrovich Nesterov

15 June 2024 in Ultrasonics
Verified
Journal Article
Closed access
VKVladimir N. Khmelev
Vladimir N. Khmelev
ASAndrey Shalunov
Andrey Shalunov
VNViktor Aleksandrovich Nesterov
Viktor Aleksandrovich Nesterov
STSergey Terentiev
Sergey Terentiev
RGRoman N. Golykh
Roman N. Golykh