Rudolf Heer

Dr. Rudolf Heer


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2011 in Review of Scientific Instruments
Verified
Journal Article
Closed access
JWJ. Wissenwasser
J. Wissenwasser
MVMichael Vellekoop
Michael Vellekoop
WKW. Kapferer
W. Kapferer
GLGünter Lepperdinger
Günter Lepperdinger
RHRudolf Heer
Rudolf Heer
An impedance measurement system with probe signal frequencies up to 50 kHz with AC-probe voltages below 30 mV rms was integrated for wireless and battery-free monitoring of microbiological cell cultures. The here presented modular design and the use of state-of-the-art components greatly eases adoptions to a wide range of biotechnological applications without the need of bulky LCR-meters or potentiostats. The device had a power consumption of less than 2.5 mA at a 3.3 V single power supply and worked trouble-free within the humid environment of a cell culture incubator. Measurements on lumped RC-elements showed an error of less than 1% for absolute values and less than 1° regarding the phase of the complex impedance. The performance of sensor devices with interdigitated electrode structures for the measurement of adherent cell cultures was tested in the presence of phosphate-buffered saline solution in the humid atmosphere of an incubator for biological cell cultures.

15 April 2026 in Electronics
Verified
Journal Article
Open access
PDF file
KEKenneth Nnanna Egwu
Kenneth Nnanna Egwu
RHRudolf Heer
Rudolf Heer
FEFerenc Ender
Ferenc Ender
GKGeorgios Kokkinis Kokkinis
Georgios Kokkinis Kokkinis
Respiratory rate (RR) is a critical indicator of physiological status, yet unobtrusive and continuous RR monitoring remains challenging, particularly in wearable applications that require soft, lightweight, and low-power sensing systems. This paper presents an integrated approach that combines a textile-embedded embroidered strain-gauge sensor with Tiny Machine Learning (TinyML) to enable real-time, on-device RR estimation. The sensing platform consists of a textile-integrated meander-pattern strain gauge and a fabric-mounted analog readout circuit, which together capture thoracic expansion during breathing. Two lightweight neural network models—a convolutional neural network (CNN) operating on raw respiratory waveforms and a dense neural network (DNN) operating on wavelet features—were developed and trained using a public strain-sensor dataset and a custom dataset collected with the textile system (TexHype dataset). Both models were optimized through 8-bit quantization and deployed to an STM32L4 microcontroller, where end-to-end on-device preprocessing, filtering, segmentation, normalization, and inference were performed. The CNN achieved the highest accuracy, with a mean absolute error (MAE) of 1.23 breaths per minute (BPM) on the TexHype dataset, but exhibited substantial inference latency (5.8–6.2 s) due to its computational complexity. In contrast, the wavelet-based DNN demonstrated lower accuracy (MAE 2.21 BPM) but achieved real-time performance with inference times of 18–96 ms, and a power overhead (ΔP=Pactive−Pidle) of approximately 3.3 mW during inference. Cross-dataset testing revealed limited generalization between different strain-sensor platforms. The findings highlight key trade-offs between accuracy, latency, and energy efficiency, and illustrate the potential of combining stretchable electronics with embedded intelligence to enable next-generation wearable respiratory monitoring systems.

1 January 2020
Verified
Conference Paper
Closed access
PDF file
ECEvangelia Chatzianagnostou
Evangelia Chatzianagnostou
AMA. Manolis
A. Manolis
GDG. Dabos
G. Dabos
DKD. Ketzaki
D. Ketzaki
BCB. Chmielak
B. Chmielak
DTD. Tsiokos
D. Tsiokos
We demonstrate a CMOS compatible interferometric plasmo-photonic sensor exploiting SisN4 photonic and aluminum (Al) plasmonic stripe waveguides. Experimental evaluation revealed bulk sensitivity of 4764 nm/RIU, holding promise for ultra-sensitive and low cost sensing devices.

1 January 2006
Verified
Book Chapter
Closed access
PDF file
RHRudolf Heer
Rudolf Heer
JSJ. Smoliner
J. Smoliner
JBJ. Bornemeier
J. Bornemeier
HBH. Brückl
H. Brückl