The development of portable biosening devices for the detection of biological entities such as biomolecules, pathogens, and cells has become extremely significant over the past years. Scientific research, driven by the promise for miniaturization and integration of complex laboratory equipment on inexpensive, reliable, and accurate devices, has successfully shifted several analytical and diagnostic methods to the submillimeter scale. The miniaturization process was made possible with the birth of microfluidics, a technology that could confine, manipulate, and mix very small volumes of liquids on devices integrated on standard silicon technology chips. Such devices are then directly translating the presence of these entities into an electronic signal that can be read out with a portable instrumentation. For the aforementioned tasks, the use of magnetic markers (magnetic particles—MPs—functionalized with ligands) in combination with the application of magnetic fields is being strongly investigated by research groups worldwide. The greatest merits of using magnetic fields are that they can be applied either externally or from integrated microconductors and they can be well-tuned by adjusting the applied current on the microconductors. Moreover, the magnetic markers can be manipulated inside microfluidic channels by high gradient magnetic fields that can in turn be detected by magnetic sensors. All the above make this technology an ideal candidate for the development of such microfluidic biosensors. In this review, focus is given only to very recent advances in biosensors that use microfluidics in combination with magnetic sensors and magnetic markers/nanoparticles.
This paper presents a novel microfluidic chip for in-vitro detection of biomolecules tagged by magnetic microparticles (MAPs) suspended in a static fluid. The system consists of two microfluidic channels: a reference channel in which bare MAPs are suspended and a detection channel in which magnetically tagged biomolecules are suspended (LMAPs). The LMAPs are functionalized MAPs (of the same magnetic volume as the ones in the reference channel) with attached biomolecules. The overall, non-magnetic volume of the LMAPs is greater than that of the bare MAPs. Current carrying microconductors are positioned underneath the channels in order to impose a magnetic field gradient to the MAPs and LMAPs and move them from the inlet to the outlet of the channels without flow. The innovative aspect of the proposed method is that the induced velocity on the MAPs and LMAPs, while imposed to the same magnetic field gradient, is inversely proportional to their overall, non-magnetic volume. This is due to the enhanced Stokes drag force exerted on the LMAPs, resulting from the greater volume and altered hydrodynamic shape. This induced velocity is measured by utilizing Giant Magnetoresistance (GMR) sensor pairs fabricated underneath the first and the last microconductors. Detected differences in velocity between the LMAPs and the reference MAPs indicate the presence of biomolecules in the static liquid sample. We also present a novel method for signal acquisition and demodulation: expensive function generators, data acquisition devices, and lock-in amplifiers were substituted by a generic PC sound card and an algorithm combining the Fast Fourier Transform of the signal with a peak detection routine. Experiments with functionalized MAPs and magnetically tagged Escherichia coli (representing the LMAPs) were carried out as a proof of concept. In order to identify the detection limit of the GMR sensor, single MAP (2.8 μm diameter) detection was performed.
In this paper, we present a versatile, dual-purpose sensor for in vitro detection of Enterobacteriaceae (e.g. Escherichia coli) and biotinylated antibodies (e.g. IgG rabbit polyclonal antibodies), based on different detection principles for each bioanalyte. These bioanalytes are tagged individually with functionalized magnetic microparticles, suspended into a static fluid and injected into a microfluidic channel. Without the need for bulk or complicated pumping systems, the functionalized microparticles are set in motion by a magnetic force exerted on them by integrated microconductors. The fundamental detection principle is the decrease in the velocity of the microparticles that are loaded with the respective bioanalyte, due to factors inhibiting their motion. The velocity of the unloaded, bare microparticles is used as a reference. We discovered a novel mechanism on which the constrained particle motion is based; in the case of E. coli, the inhibiting factor is the enhanced Stokes' drag force due to the greater volume and altered hydrodynamic shape, whereas in the case of biotinylated antibodies, it is the increased friction force at the interface between the modified microparticle and the biosensor's surface. Friction force is for the first time employed in a scheme for resolving biomolecules. Integrated magnetic microsensors are used for the velocity measurements by detecting the microparticles' stray field. Moreover, we developed a biocompatible, easy to implement and reliable surface modification that practically diminishes the problem of bioadhesion on the sensor's surface.
Bacterial contamination of water sources (e.g., lakes, rivers and springs) from waterborne bacteria is a crucial water safety issue and its prevention is of the utmost significance since it threatens the health and well-being of wildlife, livestock, and human populations and can lead to serious illness and even death. Rapid and multiplexed measurement of such waterborne pathogens is vital and the challenge is to instantly detect in these liquid samples different types of pathogens with high sensitivity and specificity. In this work, we propose a biosensing system in which the bacteria are labelled with streptavidin coated magnetic markers (MPs—magnetic particles) forming compounds (MLBs—magnetically labelled bacteria). Video microscopy in combination with a particle tracking software are used for their detection and quantification. When the liquid containing the MLBs is introduced into the developed, microfluidic platform, the MLBs are accelerated towards the outlet by means of a magnetic field gradient generated by integrated microconductors, which are sequentially switched ON and OFF by a microcontroller. The velocities of the MLBs and that of reference MPs, suspended in the same liquid in a parallel reference microfluidic channel, are calculated and compared in real time by a digital camera mounted on a conventional optical microscope in combination with a particle trajectory tracking software. The MLBs will be slower than the reference MPs due to the enhanced Stokes’ drag force exerted on them, resulting from their greater volume and altered hydrodynamic shape. The results of the investigation showed that the parameters obtained from this method emerged as reliable predictors for E. coli concentrations.
Respiratory rate (RR) is a critical indicator of physiological status, yet unobtrusive and continuous RR monitoring remains challenging, particularly in wearable applications that require soft, lightweight, and low-power sensing systems. This paper presents an integrated approach that combines a textile-embedded embroidered strain-gauge sensor with Tiny Machine Learning (TinyML) to enable real-time, on-device RR estimation. The sensing platform consists of a textile-integrated meander-pattern strain gauge and a fabric-mounted analog readout circuit, which together capture thoracic expansion during breathing. Two lightweight neural network models—a convolutional neural network (CNN) operating on raw respiratory waveforms and a dense neural network (DNN) operating on wavelet features—were developed and trained using a public strain-sensor dataset and a custom dataset collected with the textile system (TexHype dataset). Both models were optimized through 8-bit quantization and deployed to an STM32L4 microcontroller, where end-to-end on-device preprocessing, filtering, segmentation, normalization, and inference were performed. The CNN achieved the highest accuracy, with a mean absolute error (MAE) of 1.23 breaths per minute (BPM) on the TexHype dataset, but exhibited substantial inference latency (5.8–6.2 s) due to its computational complexity. In contrast, the wavelet-based DNN demonstrated lower accuracy (MAE 2.21 BPM) but achieved real-time performance with inference times of 18–96 ms, and a power overhead () of approximately 3.3 mW during inference. Cross-dataset testing revealed limited generalization between different strain-sensor platforms. The findings highlight key trade-offs between accuracy, latency, and energy efficiency, and illustrate the potential of combining stretchable electronics with embedded intelligence to enable next-generation wearable respiratory monitoring systems.
13 October 2025 in e+i Elektrotechnik und Informationstechnik
Textile integrated electronics have emerged as a promising avenue for the development of innovative biosensors for vital function monitoring. This work presents an approach to integrate electronics and sensors by means of additive manufacturing, in particular inkjet printing and dispensing, for the direct fabrication of electronic board layouts onto textiles as substrates. Three sensor modules have been fabricated; a heart rate sensor, a breath rate sensor and an accelerometer. The process starts with printing dielectric islands, the insulating layer, followed by the layout using conductive ink. Finally, the integrated circuits are assembled using anisotropic conductive tape which facilitates the seamless integration and ensures robust electrical connections and mechanical stability. Lastly, an advanced readout and data logging scheme based on the Eclipse ThreadX real-time Operating System (RTOS) has been developed. The read-out electronics are based on the STM32L4+ microcontroller unit family. Its ultra-low power modes and computational power allow complex data processing which enables a new generation of wearable devices. The Eclipse ThreadX is an open source RTOS with considerable advantages over its counterparts, namely, its performance, determinism, code quality and functional safety. We present an advanced read-out software architecture for logging data from the three sensor modules. The integration of these cutting-edge components enhances computational capabilities but also ensures real-time data processing and communication for the proposed vital function monitoring system, opening new possibilities for wearable applications in healthcare.