Yi Qian

Prof. Yi Qian

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2020 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
XDXilei Dai
Xilei Dai
LHLixiang Huang
Lixiang Huang
YQYi Qian
Yi Qian
SXShuang Xia
Shuang Xia
WCWinston Chong
Winston Chong
COChubin Ou
Chubin Ou

28 November 2013 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
WCW. Chong
W. Chong
YZYu Zhang
Yu Zhang
YQYi Qian
Yi Qian
LLL. Lai
L. Lai
GPG. Parker
G. Parker
KMK. Mitchell
K. Mitchell
BACKGROUND AND PURPOSE: Recent studies have shown promising results regarding intracranial aneurysms treated with flow diverters. However, these have had adverse effects, including delayed aneurysm occlusion, posttreatment symptoms, and rupture. The hemodynamic profiles of aneurysms treated with flow diverters were analyzed to determine the ones associated with successful and failed treatments. MATERIALS AND METHODS: Patient-specific computational fluid dynamics were used to simulate hemodynamic profiles, including the presence of jet flow, energy loss, volume flow, and wall shear stress in 4 successful occlusions of aneurysms and 4 failed cases after flow-diverter deployment. In these 4 failed cases, hemodynamic profiles were examined again after a hypothetic second intervention. This involved replacing the failed flow diverter with a hypothetic optimally deployed flow diverter or simulated placement of a second flow diverter within the first (double hypothetic optimally deployed). RESULTS: Where successful occlusions were achieved, a marked obliteration of jet flow was observed. Flow entering the aneurysm sac was diverted via the center of the flow diverter and joined smoothly with the continuation of flow leaving the aneurysm sac into the parent arteries. These observations were supplemented by a reduction in the other hemodynamic profiles. Aneurysm neck geometry might influence the efficacy of the flow diverter. CONCLUSIONS: Hemodynamic indices, as calculated by using computational fluid dynamics techniques, have close correlation with flow-diverter treatment outcome. Computational fluid dynamics could be potentially useful as a planning tool for neurointerventionists by simulating an optimized flow-diverter deployment strategy before the procedure and evaluating posttreatment outcome.

1 January 2015 in Journal of Biomechanics
Verified
Journal Article
Closed access
KKKaavya Karunanithi
Kaavya Karunanithi
CHCong Han
Cong Han
CLChang-Joon Lee
Chang-Joon Lee
WSWanchao Shi
Wanchao Shi
LDLian Duan
Lian Duan
YQYi Qian
Yi Qian

14 October 2020 in European Radiology
Verified
Journal Article
Closed access
PDF file
COChubin Ou
Chubin Ou
WCWinston Chong
Winston Chong
CDChuan-Zhi Duan
Chuan-Zhi Duan
XZXin Zhang
Xin Zhang
MMMichael Morgan
Michael Morgan
YQYi Qian
Yi Qian

1 September 2018 in Journal of Neurosurgery
Verified
Journal Article
Closed access
PDF file
FZFengping Zhu
Fengping Zhu
YQYi Qian
Yi Qian
BXBin Xu
Bin Xu
YGYuxiang Gu
Yuxiang Gu
KKKaavya Karunanithi
Kaavya Karunanithi
MMMichael K. Morgan
Michael K. Morgan
OBJECTIVE: Although intracranial vessel remodeling has been observed in moyamoya disease, concerns remain regarding the effect of bypass surgery on hemodynamic changes within the internal carotid artery (ICA). The authors aimed to quantify the surgical effect of bypass surgery on bilateral ICAs in moyamoya disease and to estimate pressure drop (PD) along the length of the ICA to predict surgical outcomes.METHODS: Records of patients who underwent bypass surgery for treatment of moyamoya disease and in whom flow rates were obtained pre- and postsurgery by quantitative MR angiography were retrospectively reviewed. Quantitative MR angiography and computational fluid dynamics were applied to measure morphological and hemodynamic changes during pre- and postbypass procedures. The results for vessel diameter, volumetric flow, PD, and mean wall shear stress along the length of the ICA were analyzed. Subgroup analysis was performed for the circle of Willis (CoW) configurations.RESULTS: Twenty-three patients were included. The PD in ICAs on the surgical side (surgical ICAs) decreased by 21.18% (SD ± 30.1%) and increased by 11.75% (SD ± 28.6%) in ICAs on the nonsurgical side (contralateral ICAs) (p = 0.001). When the PD in contralateral ICAs was compared between patients with a complete or incomplete CoW, the authors found that the PDI in the former group decreased by 2.45% and increased by 20.88% in the latter (p = 0.05). Regression tests revealed that a greater postoperative decrease in PD corresponded to shrinking of ICAs (R2 = 0.22, p = 0.02).CONCLUSIONS: PD may be used as a reliable biomechanical indicator for the assessment of surgical treatment outcomes. The vessel remodeling characteristics of contralateral ICA were related to CoW configurations.

1 February 2020 in Journal of Biomechanics
Verified
Journal Article
Closed access
YLYujie Li
Yujie Li
DVDavid I. Verrelli
David I. Verrelli
WYWilliam Yang
William Yang
YQYi Qian
Yi Qian
WCWinston Chong
Winston Chong