Yu Zhang

Dr. Yu Zhang

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2019 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
DLDonghai Li
Donghai Li
YLYongjian Li
Yongjian Li
GLGuiling Li
Guiling Li
YZYu Zhang
Yu Zhang
JLJiang Li
Jiang Li
HCHaosheng Chen
Haosheng Chen
Significance: It is always a challenge to see the deposition of single PM 2.5 particles, the harmful inhalable aerosols in the polluted air, in alveolar region, and their invasion to the extrapulmonary organs. The dynamic deposition process and the nonuniform deposition pattern of PM 2.5 in the alveolar region are revealed using a fluorescent imaging method with high temporal and spatial resolutions. This observation technology would also bring insight in the study of the public health in air pollution and lung administration.

28 November 2013 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
WCW. Chong
W. Chong
YZYu Zhang
Yu Zhang
YQYi Qian
Yi Qian
LLL. Lai
L. Lai
GPG. Parker
G. Parker
KMK. Mitchell
K. Mitchell
BACKGROUND AND PURPOSE: Recent studies have shown promising results regarding intracranial aneurysms treated with flow diverters. However, these have had adverse effects, including delayed aneurysm occlusion, posttreatment symptoms, and rupture. The hemodynamic profiles of aneurysms treated with flow diverters were analyzed to determine the ones associated with successful and failed treatments. MATERIALS AND METHODS: Patient-specific computational fluid dynamics were used to simulate hemodynamic profiles, including the presence of jet flow, energy loss, volume flow, and wall shear stress in 4 successful occlusions of aneurysms and 4 failed cases after flow-diverter deployment. In these 4 failed cases, hemodynamic profiles were examined again after a hypothetic second intervention. This involved replacing the failed flow diverter with a hypothetic optimally deployed flow diverter or simulated placement of a second flow diverter within the first (double hypothetic optimally deployed). RESULTS: Where successful occlusions were achieved, a marked obliteration of jet flow was observed. Flow entering the aneurysm sac was diverted via the center of the flow diverter and joined smoothly with the continuation of flow leaving the aneurysm sac into the parent arteries. These observations were supplemented by a reduction in the other hemodynamic profiles. Aneurysm neck geometry might influence the efficacy of the flow diverter. CONCLUSIONS: Hemodynamic indices, as calculated by using computational fluid dynamics techniques, have close correlation with flow-diverter treatment outcome. Computational fluid dynamics could be potentially useful as a planning tool for neurointerventionists by simulating an optimized flow-diverter deployment strategy before the procedure and evaluating posttreatment outcome.

1 November 2015 in Journal of Wind Engineering and Industrial Aerodynamics
Verified
Journal Article
Closed access
GHGang Hu
Gang Hu
KTK.T. Tse
K.T. Tse
KKK.C.S. Kwok
K.C.S. Kwok
YZYu Zhang
Yu Zhang

9 August 2012 in Medical Engineering & Physics
Verified
Journal Article
Closed access
YZYu Zhang
Yu Zhang
WCW. Chong
W. Chong
YQY. Qian
Y. Qian
Flow diverters (FDs) are high density meshed stents designed to reduce blood flow into intra-cranial aneurysms. Though the FD is one of many intracranial aneurysm (IA) treatments, FD implantation may also result in the growth and rupture of residual aneurysms. The purpose of this research is to investigate the effect of FD implantation on IA hemodynamics. Computational fluid dynamics (CFD) was conducted to analyze dynamic and resistance forces after FD deployment. Simulation results for the successful case (patient A) showed that FD flow resistance force was higher than dynamic force. This indicated that the FD provided sufficient resistance to reduce flow into the aneurysm. As a result, flow velocity magnitude at the aneurysm neck was reduced by 95%. On the other hand, the flow velocity magnitude at the aneurysm neck was reduced by about 50% for the unsuccessful case (patient B). The reason was that the flow resistance force at the aneurysm neck section was calculated to be lower than the flow driving force. In order to completely occlude the aneurysm, a higher resistance FD stent is to be required to suppress the dynamic forces. Patient-specific hemodynamic simulations offer means of quantitative estimation FD treatment outcomes.

1 September 2015 in Environmental Pollution
Verified
Journal Article
Closed access
YZYu Zhang
Yu Zhang
KKK.C.S. Kwok
K.C.S. Kwok
XLX.-P. Liu
X.-P. Liu
JNJ.-L. Niu
J.-L. Niu

1 September 2013 in Journal of Biomechanics
Verified
Journal Article
Closed access
CLC.J. Lee
C.J. Lee
YZYu Zhang
Yu Zhang
HTH. Takao
H. Takao
YMY. Murayama
Y. Murayama
YQY. Qian
Y. Qian