Carlos Nakase-Rodríguez

Dr. Carlos Nakase-Rodríguez


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2019 in Water
Verified
Journal Article
Open access
PDF file
SERGIO ZAMORASERGIO ZAMORA
SERGIO ZAMORA
José Luis Marín-MuñizJosé Luis Marín-Muñiz
José Luis Marín-Muñiz
CNCarlos Nakase-Rodríguez
Carlos Nakase-Rodríguez
GLGregorio Fernández Lambert
Gregorio Fernández Lambert
Luis Carlos Sandoval-HerazoLuis Carlos Sandoval-Herazo
Luis Carlos Sandoval-Herazo
Constructed wetlands (CWs) are sustainable technologies where the channels are filled with porous material and plants, which collectively remove pollutants, depending on the type of substrate and vegetation. This study evaluated CWs and their functionality by comparing three ornamental plants (Canna indica, Cyperus papyrus, and Hedychium coronarium) as a phytoremediation process of wastewater, in CWs filled with layers of porous stone–tepezil–plastic residues–soil (S-A), or in microcosms with layers of porous stone–tepezil–soil without the presence of plastic (S-B). The findings during 180 days showed that the removals of pollutants (chemical oxygen demand (COD), total solids suspended (TSS), nitrogen as ammonium (N-NH4), as nitrate (N-NO3), and phosphate (P-PO4) were 20%–60% higher in microcosms with plants than in the absence of plants. Statistical differences were not observed when comparing removal effects among S-A and S-B, indicating that plastic residues as filter material in CWs did not affect the pollutant removal, growth, flowering, and shoots of plants. The use of plastic residues as filter may represent a less costly alternative in CW establishments. Dependence on N-NH4 and TSS removal was observed according to plant species. The three species used are suitable for using in CWs as wastewater treatment. In addition, the ornamental plants could generate interest for a commercial option.

CNCarlos Nakase-Rodríguez
Carlos Nakase-Rodríguez
Florentina ZuritaFlorentina Zurita
Florentina Zurita
Graciela NaniGraciela Nani
Graciela Nani
GRGuillermo Reyes
Guillermo Reyes
GLGregorio Fernández Lambert
Gregorio Fernández Lambert
Luis Carlos Sandoval-HerazoLuis Carlos Sandoval-Herazo
Luis Carlos Sandoval-Herazo
Vertical partially saturated (VPS) constructed wetlands (CWs) are a novel wastewater treatment system for which little information is known about its design parameters and performance under tropical climates. The objective of this study is to evaluate the nitrogen removal process from domestic wastewater and the production of tropical ornamental plants (Canna hybrids and Zantedeschia aethiopica) in VPS CWs at a mesocosms scale. Nine VPS CWs, with a free-flow zone of 16 cm and a saturated zone of 16 cm, were used as experimental units. Three units were planted with Canna hybrids., and three, with Zantedeschia aethiopica (one plant per unit); the remaining three units were established as controls without vegetation. They were fed with domestic wastewater intermittently and evaluated for the elimination of COD, N-NH4, N-NO3, Norg, NT, and PT. The results showed an increase in the removal for some pollutants in the vegetated systems, i.e., N-NH4 (35%), Norg (16%), TN (25%), and TP (47%) in comparison to the unvegetated systems. While N-NO3 removal showed better removal in 10% of the systems without vegetation, no significant differences were found (p > 0.05) for COD removal. The aerobic and anaerobic conditions in the VPS CWs favor the elimination of pollutants in the systems, and also the development of the tropical species evaluated in this study; good development was exhibited by a high growth rate and biomass production.

MSMayerlin Sandoval-Herazo
Mayerlin Sandoval-Herazo
Graciela NaniGraciela Nani
Graciela Nani
Florentina ZuritaFlorentina Zurita
Florentina Zurita
CNCarlos Nakase-Rodríguez
Carlos Nakase-Rodríguez
SERGIO ZAMORASERGIO ZAMORA
SERGIO ZAMORA
Erick Arturo Betanzo TorresErick Arturo Betanzo Torres
Erick Arturo Betanzo Torres
The appearance of SARS-CoV-2 represented a new health threat to humanity and affected millions of people; the transmission of this virus occurs through different routes, and one of them recently under debate in the international community is its possible incorporation and spread by sewage. Therefore, the present work’s research objectives are to review the presence of SARS-CoV-2 in wastewater throughout the world and to analyze the coverage of wastewater treatment in Mexico to determine if there is a correlation between the positive cases of COVID-19 and the percentages of treated wastewater in Mexico as well as to investigate the evidence of possible transmission by aerosol sand untreated wastewater. Methodologically, a quick search of scientific literature was performed to identify evidence the presence of SARS-CoV-2 RNA (ribonucleic acid) in wastewater in four international databases. The statistical information of the positive cases of COVID-19 was obtained from data from the Health Secretary of the Mexican Government and the Johns Hopkins Coronavirus Resource Center. The information from the wastewater treatment plants in Mexico was obtained from official information of the National Water Commission of Mexico. The results showed sufficient evidence that SARS-CoV-2 remains alive in municipal wastewater in Mexico. Our analysis indicates that there is a low but significant correlation between the percentage of treated water and positive cases of coronavirus r = −0.385, with IC (95%) = (−0.647, −0.042) and p = 0.030; this result should be taken with caution because wastewater is not a transmission mechanism, but this finding is useful to highlight the need to increase the percentage of treated wastewater and to do it efficiently. In conclusions, the virus is present in untreated wastewater, and the early detection of SAR-CoV-2 could serve as a bioindicator method of the presence of the virus. This could be of great help to establish surveillance measures by zones to take preventive actions, which to date have not been considered by the Mexican health authorities. Unfortunately, wastewater treatment systems in Mexico are very fragile, and coverage is limited to urban areas and non-existent in rural areas. Furthermore, although the probability of contagion is relatively low, it can be a risk for wastewater treatment plant workers and people who are close to them.