Shu-Hsien Liao

Prof. Shu-Hsien Liao

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2006 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
HYHong-Chang Yang
Hong-Chang Yang
SLShu-Hsien Liao
Shu-Hsien Liao
HHHerng-Er Horng
Herng-Er Horng
SKShing-Ling Kuo
Shing-Ling Kuo
HCHsin-Hsien Chen
Hsin-Hsien Chen
SYS. Y. Yang
S. Y. Yang
We applied prepolarization field and high-Tc superconducting quantum interference device (SQUID) detector to enhance nuclear magnetic resonance signal in a microtesla magnetic field. The minimum measuring magnetic field is 8.9μT at which the proton resonance frequency is 380Hz . The specificity instrumentation and the difficulty of using a high-Tc SQUID with prepolarization field were investigated. We applied gradient field to perform one-dimensional proton imaging in a microtesla magnetic field. Additionally, low field high-Tc SQUID-based NMR systems are promising in biomagnetic research due to its use, for example, in imaging with hyperpolarized noble gas.

11 November 2010 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
MCMing-Jang Chiu
Ming-Jang Chiu
HHH. E. Horng
H. E. Horng
Jen-Jie ChiehJen-Jie Chieh
Jen-Jie Chieh
SLShu-Hsien Liao
Shu-Hsien Liao
CCC. H. Chen
C. H. Chen
HYH. C. Yang
H. C. Yang
Via immunomagnetic reduction assay, bio-molecules can be quantitatively detected with the aid of bio-functionalized magnetic nanoparticles, which are used as labeling markers for specific bio-molecules. To achieve an ultra-high sensitivity in the detection of bio-molecules, the superconducting quantum interference device (SQUID) looks very promising as a sensor for the magnetic signal that are related to the concentration of the detected bio-molecules. We had developed a single channel SQUID-based magnetosusceptometer, but for increasing the detection through-put, we have developed a multi-channel SQUID-based magnetosusceptometer. In this work, the design and the working principle of a 4-channel SQUID-based magnetosusceptometer are introduced. By utilizing scanning technology, 4 samples can be logged into a SQUID-based magnetosusceptometer simultaneously. Be noted that only one single SQUID magnetometer has been used in the magnetosusceptometer. The precision and the sensitivity of detecting bio-molecules by using a 4-channel SQUID-based magnetosusceptometer have been investigated. The detected bio-molecules are biomarkers for Alzheimer's disease.

27 December 2010 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
SLShu-Hsien Liao
Shu-Hsien Liao
KHKAI-WEN HUANG
KAI-WEN HUANG
HYHong-Chang Yang
Hong-Chang Yang
CYChang-Te Yen
Chang-Te Yen
MCM. J. Chen
M. J. Chen
SYShieh Yueh Yang
Shieh Yueh Yang
The characterization of cancerous livers in rats using nuclear magnetic resonance and magnetic resonance imaging (NMR/MRI) based on high-Tc superconducting quantum interference devices (SQUIDs) is presented. The T1−1 were observed to be 6.5±0.5 s−1 for controlled livers and 2.85±0.2 s−1 for cancerous livers, which indicate that the T1 can be used to distinguish the cancerous tissues from controlled liver tissues. The intensity ratio for tap water, cancerous tissue, and controlled tissue, respectively, is 1:1.15:0.56 at TBp=1 s . The SQUID-detected NMR/MRI exhibits potential applications in research and clinics.

15 June 2006 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
HYH. C. Yang
H. C. Yang
SYS. Y. Yang
S. Y. Yang
GFG. L. Fang
G. L. Fang
WHW. H. Huang
W. H. Huang
CLC. H. Liu
C. H. Liu
CHChin-Yih Hong
Chin-Yih Hong
Due to their ultrahigh sensitivity to magnetic flux, superconducting quantum interference devices (SQUIDs) are able to detect biomagnetic signals. By labeling biotargets with magnetic nanoparticles, several groups have shown that SQUIDs are promising as quantitative probes of biotargets by measuring their magnetic properties. In this work, we describe the design and construction of a high-transition-temperature radio-frequency SQUID magnetometer system for measuring the magnetic relaxation of labeled avidin. We also describe the synthesis of magnetic nanoparticles coated with biotin for use in labeling the avidin. Furthermore, the specifications of the SQUID-based magnetically labeled immunoassay of avidin are explored.

4 March 2009 in Superconductor Science and Technology
Verified
Journal Article
Closed access
SLShu-Hsien Liao
Shu-Hsien Liao
HYHong-Chang Yang
Hong-Chang Yang
HHHerng-Er Horng
Herng-Er Horng
SYS Y Yang
S Y Yang
HCH H Chen
H H Chen
LHLian-Pin Hwang
Lian-Pin Hwang

23 December 2008 in Superconductor Science and Technology
Verified
Journal Article
Closed access
SLShu-Hsien Liao
Shu-Hsien Liao
HYHong-Chang Yang
Hong-Chang Yang
HHHerng-Er Horng
Herng-Er Horng
SYS Y Yang
S Y Yang