Industrial archived process data represent a convenient source of information for data-driven models, such as artificial neural network (ANN), that can be used for safety and efficiency improvement like early or even predictive fault detection and diagnosis (FDD). Nonetheless, most of the data used for model generation are representative of the process nominal states and therefore are not enough for classification problems intended to determine abnormal process conditions. This work proposes the use of techniques to augment the original real data standards, dismissing the need for experiments that could jeopardize process safety. It uses the Monte Carlo technique to artificially increase the number of model inputs coupled to the nearest neighbor search (NNS) by geometric distances to consistently classify the generated patterns in normal or faulty statuses. Finally, a radial basis function neural network is trained with the augmented data. The methodology was validated by a study case in which 3381 pulp and paper industrial data points were expanded to monitor the formation of particles in a recovery boiler. Only 5.8% of the original process data were examples of faulty conditions, but the new expanded and balanced data collection leveraged the classification performance of the neural network, allowing its future use for monitoring purpose.
1 March 2020 in Brazilian Journal of Chemical Engineering
A quartz crystal microbalance-based biosensor for the specific detection of the first transgenic common bean (Phaseolus vulgaris L.) cultivar (BRS FC401 RMD) with resistance to bean golden mosaic virus (BGMV) was developed. The immobilization chemistry relies on the strong bond between the thiolated probe and the gold electrode surface. The probe sequence is internal to a region of the BGMV rep gene that was introduced into the common bean genome. The sensor's analytical performance was determined using synthetic oligonucleotides. Real samples of transgenic and wild-type bean seeds were also tested. Sample pretreatment consisted only of enzymatic fragmentation, followed by a thermal denaturation step combined with blocking oligonucleotides. Different biosensor regeneration approaches were studied. Immobilization showed good reproducibility (CV% of 5.8%). The biosensor proved specific for both synthetic oligonucleotides and non-amplified genomic DNA. A linear detection range of 0–1.4 ng/µL was observed, with a detection limit of 0.18 ng/µL. Three sequential detections were performed without loss of surface activity. The results demonstrate the biosensor's potential for direct, real-time, label-free detection of DNA samples for field screening of transgenic common bean cultivars.
6 February 2020 in Brazilian Journal of Chemical Engineering
A quartz crystal microbalance-based biosensor for the specific detection of the first transgenic common bean (L.) cultivar (BRS FC401 RMD) with resistance to Bean golden mosaic virus (BGMV) was developed. The immobilization chemistry relies on the strong bond between the thiolated probe and the gold electrode surface. The probe sequence is internal to a region of the BGMV rep gene that was introduced into the common bean genome. The sensor’s analytical performance was determined using synthetic oligonucleotides. Real samples of transgenic and wild-type bean seeds were also tested. Sample pretreatment consisted only of enzymatic fragmentation, followed by a thermal denaturation step combined with blocking oligonucleotides. Different biosensor regeneration approaches were studied. Immobilization showed good reproducibility (CV% of 5.8%). The biosensor proved specific for both synthetic oligonucleotides and non-amplified genomic DNA. A linear detection range of 0–1.4 ng/µL was observed, with a detection limit of 0.18 ng/µL. Three sequential detections were performed without loss of surface activity. The results demonstrate the biosensor’s potential for direct, real-time, label-free detection of DNA samples for field screening of transgenic common bean cultivars.