Phenols are toxic compounds that are present in several industrial wastewaters, so their quantification has great environmental importance. In order to permit an analytical methodology for in situ monitoring, this work aims to study the application of Agaricus bisporus tissue as a source of tyrosinase and the optimum reaction conditions for the development of a phenol biosensor. Such an enzyme is a polyphenol oxidase that transforms many different phenolic compounds into quinones. Experiments with fungi tissue were performed to evaluate different sizes of tissue (0.5, 1.0 and 1.5 cm), different temperatures (23.5°C to 60°C), and different pH values (6, 7 and 8) to quantify analytically phenol content. Amongst the tested conditions, those that had presented larger efficiency in phenol oxidation were attained with the fungal tissue size of 1 cm, at pH 8.0, in the temperature range from 35°C to 45°C.
With the aim of searching for an in situ method for monitoring phenol, Agaricus bisporus tissue with tyrosine activity was used as a biocomponent and an oxygen electrode used as a transducer to develop a biosensor. The experimental methodology investigated the relation between dissolved oxygen and phenol concentration using a standard solution. Biosensor calibration was evaluated by studying reaction time and tissue amount necessary to promote a reliable response and to minimize errors. The influence of air saturation of the sample and washing of the electrode was also investigated. Results showed that 5 g of mushroom tissue with a 1 min reaction time promoted the best biosensor response within a phenol concentration range of 5–10 ppm. Washing of the electrode did not change the performance of the analysis; however, initial air saturation caused less variation amongst the samples.
Tyrosinase enzyme in a crude extract was immobilized in granular activated carbon (GAC) and activated chitosan beads (ACBs), two low-cost supports. It was possible to immobilize up to 70% of the enzymes in GAC under the conditions of 20 g/L support, stirring of 15.7 rad/s, contact time of 120 min, and up to 100% of enzymes in ACBs under the same conditions. In enzymatic oxidation tests, tyrosinase immobilized in GAC (T-GAC) was able to achieve a final phenol concentration below the limit required by the Brazilian legislation (0.5 mg/L) for solutions with initial concentrations of 10 mg/L, while the enzyme immobilized in ACBs (T-ACBs) was able to conform solutions with initial concentrations of phenol of 40 mg/L. It was possible to reuse the T-GAC two times, maintaining the same phenol removal efficiency, while the T-ACBs maintained up to 98% of its efficiency after five cycles of enzymatic oxidation of solutions of 10 mg/L phenol. It was possible to achieve the same phenol removal efficiency, with immobilized enzymes stored for up to 2 weeks. Such results suggest that both materials are effective for phenol removal from water samples, especially T-ACBs, representing promising alternatives for mitigating the effects of this compound in industrial wastewater.
Neste trabalho é proposto um biossensor amperométrico a partir da extração da enzima peroxidase presente no tecido do feijão (Phaseolus vulgaris L.), visan...
A quartz crystal microbalance-based biosensor for the specific detection of the first transgenic common bean (Phaseolus vulgaris L.) cultivar (BRS FC401 RMD) with resistance to bean golden mosaic virus (BGMV) was developed. The immobilization chemistry relies on the strong bond between the thiolated probe and the gold electrode surface. The probe sequence is internal to a region of the BGMV rep gene that was introduced into the common bean genome. The sensor's analytical performance was determined using synthetic oligonucleotides. Real samples of transgenic and wild-type bean seeds were also tested. Sample pretreatment consisted only of enzymatic fragmentation, followed by a thermal denaturation step combined with blocking oligonucleotides. Different biosensor regeneration approaches were studied. Immobilization showed good reproducibility (CV% of 5.8%). The biosensor proved specific for both synthetic oligonucleotides and non-amplified genomic DNA. A linear detection range of 0–1.4 ng/µL was observed, with a detection limit of 0.18 ng/µL. Three sequential detections were performed without loss of surface activity. The results demonstrate the biosensor's potential for direct, real-time, label-free detection of DNA samples for field screening of transgenic common bean cultivars.
A quartz crystal microbalance-based biosensor for the specific detection of the first transgenic common bean (L.) cultivar (BRS FC401 RMD) with resistance to Bean golden mosaic virus (BGMV) was developed. The immobilization chemistry relies on the strong bond between the thiolated probe and the gold electrode surface. The probe sequence is internal to a region of the BGMV rep gene that was introduced into the common bean genome. The sensor’s analytical performance was determined using synthetic oligonucleotides. Real samples of transgenic and wild-type bean seeds were also tested. Sample pretreatment consisted only of enzymatic fragmentation, followed by a thermal denaturation step combined with blocking oligonucleotides. Different biosensor regeneration approaches were studied. Immobilization showed good reproducibility (CV% of 5.8%). The biosensor proved specific for both synthetic oligonucleotides and non-amplified genomic DNA. A linear detection range of 0–1.4 ng/µL was observed, with a detection limit of 0.18 ng/µL. Three sequential detections were performed without loss of surface activity. The results demonstrate the biosensor’s potential for direct, real-time, label-free detection of DNA samples for field screening of transgenic common bean cultivars.