Maryam Mobed-Miremadi

Dr. Maryam Mobed-Miremadi

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2018 in Bioengineering
Verified
Journal Article
Open access
PDF file
CFChantell Farias
Chantell Farias
RLRoman Lyman
Roman Lyman
CHCecilia Hemingway
Cecilia Hemingway
HCHuong Chau
Huong Chau
AMAnne Mahacek
Anne Mahacek
MMMaryam Mobed-Miremadi
Maryam Mobed-Miremadi
Cell-hydrogel based therapies offer great promise for wound healing. The specific aim of this study was to assess the viability of human hepatocellular carcinoma (HepG2) cells immobilized in atomized alginate capsules (3.5% (w/v) alginate, d = 225 µm ± 24.5 µm) post-extrusion through a three-dimensional (3D) printed methacrylate-based custom hollow microneedle assembly (circular array of 13 conical frusta) fabricated using stereolithography. With a jetting reliability of 80%, the solvent-sterilized device with a root mean square roughness of 158 nm at the extrusion nozzle tip (d = 325 μm) was operated at a flowrate of 12 mL/min. There was no significant difference between the viability of the sheared and control samples for extrusion times of 2 h (p = 0.14, α = 0.05) and 24 h (p = 0.5, α = 0.05) post-atomization. Factoring the increase in extrusion yield from 21.2% to 56.4% attributed to hydrogel bioerosion quantifiable by a loss in resilience from 5470 (J/m3) to 3250 (J/m3), there was no significant difference in percentage relative payload (p = 0.2628, α = 0.05) when extrusion occurred 24 h (12.2 ± 4.9%) when compared to 2 h (9.9 ± 2.8%) post-atomization. Results from this paper highlight the feasibility of encapsulated cell extrusion, specifically protection from shear, through a hollow microneedle assembly reported for the first time in literature.

3 April 2016 in Artificial Cells, Nanomedicine, and Biotechnology
Verified
Journal Article
Closed access
PDF file
JHJared Hara
Jared Hara
JTJordan Tottori
Jordan Tottori
MAMegan Anders
Megan Anders
SDSmritee Dadhwal
Smritee Dadhwal
Prashanth AsuriPrashanth Asuri
Prashanth Asuri
MMMaryam Mobed-Miremadi
Maryam Mobed-Miremadi
Post cryopreservation viability of human embryonic kidney (HEK) cells under two-dimensional (2D) and three-dimensional (3D) culture conditions was studied using trehalose as the sole cryoprotective agent. An L9 (34) Taguchi design was used to optimize the cryoprotection cocktail seeding process prior to slow-freezing with the specific aim of maximizing cell viability measured 7 days post thaw, using the combinatorial cell viability and in-vitro cytotoxicity WST assay. At low (200 mM) and medium (800 mM) levels of trehalose concentration, encapsulation in alginate offered a greater protection to cryopreservation. However, at the highest trehalose concentration (1200 mM) and in the absence of the pre-incubation step, there was no statistical difference at the 95% CI (p = 0.0212) between the viability of the HEK cells under 2D and 3D culture conditions estimated to be 17.9 ± 4.6% and 14.0 ± 3.6%, respectively. A parallel comparison between cryoprotective agents conducted at the optimal levels of the L9 study, using trehalose, dimethylsulfoxide and glycerol in alginate microcapsules yielded a viability of 36.0 ± 7.4% for trehalose, in average 75% higher than the results associated with the other two cell membrane-permeating compounds. In summary, the effectiveness of trehalose has been demonstrated by the fact that 3D cell cultures can readily be equilibrated with trehalose before cryopreservation, thus mitigating the cytotoxic effects of glycerol and dimethylsulfoxide.

19 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
NKNicholas Kikuchi
Nicholas Kikuchi
MMMargaret May
Margaret May
MZMatthew Zweber
Matthew Zweber
JMJerard Madamba
Jerard Madamba
CSCraig Stephens
Craig Stephens
MMMaryam Mobed-Miremadi
Maryam Mobed-Miremadi
There are no existing affordable diagnostics for sensitive, rapid, and on-site detection of pathogens in milk. To this end, an on-site colorimetric-based sustainable assay has been developed and optimized using an L16 (54) Taguchi design to obtain results in hours without PCR amplification. To determine the level of Escherichia coli (E. coli) contamination, after induction with 150 µL of breast milk, the B-Per bacterial protein extraction kit was added to a solution containing an alginate-based microcapsule assay. Within this 3 mm spherical novel sensor design, X-Gal (5-Bromo-4-Chloro-3-Indolyl β-d-Galactopyranoside) was entrapped at a concentration of 2 mg/mL. The outward diffusing X-Gal was cleaved by β-galactosidase from E. coli and dimerized in the solution to yield a blue color after incubation at 40 °C. Color intensity was correlated with the level of E. coli contamination using a categorical scale. After an 8 h incubation period, a continuous imaging scale based on intensity normalization was used to determine a binary lower limit of detection (LOD), which corresponded to 102 colony forming unit per mL (CFU/mL) and above. The cost of the overall assay was estimated to be $0.81 per sample, well under the $3 benchmark for state-of-the-art immune-based test kits for pathogen detection in biofluids. Considering the reported binary LOD cutoff of 102 CFU/mL and above, this proposed hydrogel-based assay is suited to meet global requirements for screening breast milk or milk for pathogenic organisms of 104 CFU/mL, with a percentage of false positives to be determined in future efforts.

26 September 2022 in Frontiers in Molecular Biosciences
Verified
Journal Article
Open access
DJDwight Johnson
Dwight Johnson
UKUnyoung Kim
Unyoung Kim
MMMaryam Mobed-Miremadi
Maryam Mobed-Miremadi
Cross-linked hydrogel substrates have garnered attention as they simultaneously enable oxidoreductase reactions in a control volume extended to adsorption of redox capacitors for amplification of electrochemical signals. In this study, the effect of catalase immobilization in mold-casted alginate-based thin films (1 mm × 6 mm × 10 mm) containing multi walled carbon nanotubes (MWCNT) coated with chitosan has been studied via amperometry. The amperometric response was measured as a function of peroxide concentration, at a fixed potential of −0.4 V vs. SPCE in phosphate-buffered saline (pH = 7.4). Results indicate substrate detection is not diffusion-limited by the 100 μm thick chitosan layer, if the cationic polyelectrolyte is in contact with the sensing carbon electrode, and the linear detection of the enzyme absent in solution is enabled by immobilization (R2 = 0.9615). The ferricyanide-mediated biosensor exhibited a sensitivity of 4.55 μA/mM for the optimal formulation at room temperature comparable to other nanomaterial hybrid sensing solution namely amine-functionalized graphene with an average response time of 5 s for the optimal formulation. The suitability of the optimized chitosan-coated alginate slabs nano-environment for co-encapsulation of catalase and carbon nanotubes was confirmed by cyclic voltammetry.

22 March 2024 in Applied Mechanics
Verified
Journal Article
Open access
PDF file
KDKendall Marie Defelippi
Kendall Marie Defelippi
AKAllyson Yuuka Saumei Kwong
Allyson Yuuka Saumei Kwong
JAJulia Rose Appleget
Julia Rose Appleget
RARana Altay
Rana Altay
MMMaya Bree Matheny
Maya Bree Matheny
MMMaryam Mobed-Miremadi
Maryam Mobed-Miremadi
A variety of hollow microneedle (HMN) designs has emerged for minimally invasive therapies and monitoring systems. In this study, a design change limiting the indentation depth of the (3D) printed custom microneedle assembly (circular array of five conical frusta with and without a stopper, aspect ratio = 1.875) fabricated using stereolithography has been experimentally validated and modeled in silico. The micro-indentation profiles generated in confined compression on 1 mm ± 0.073 mm alginate films enabled the generation of a Prony series, where displacement ranged from 100 to 250 µm. These constants were used as intrinsic properties simulating experimental ramp/release profiles. Puncture occurred on two distinct hydrogel formulations at the design depth of 150 µm and indentation rate of 0.1 mm/s characterized by a peak force of 3.5 N (H = 31 kPa) and 8.3 N (H = 36.5 kPa), respectively. Experimental and theoretical alignments for peak force trends were obtained when the printing resolution was simulated. Higher puncture force and uniformity inferred by the stopper was confirmed via microscopy and profilometry. Meanwhile, poroviscoelasticity characterization is required to distinguish mass loss vs. redistribution post-indentation through pycnometry. Results from this paper highlight the feasibility of insertion-depth control within the epidermis thickness for the first time in solid HMN literature.

8 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
AHAlex Hadsell
Alex Hadsell
HCHuong Cam Tran Chau
Huong Cam Tran Chau
RBRichard P Barber
Richard P Barber
UKUnyoung Kim
Unyoung Kim
MMMaryam Mobed-Miremadi
Maryam Mobed-Miremadi
Nanoporous dialysis membranes made of regenerated cellulose are used as molecular weight cutoff standards in bioseparations. In this study, mesoporous standards with Stokes’ radii (50 kDa/2.7 nm, 100 kDa/3.4 nm and 1000 kDa/7.3 nm) and overlapping skewed distributions were characterized using AFM, with the specific aim of generating pore size classifiers for biomimetic membranes using supervised learning. Gamma transformation was used prior to conducting discriminant analysis in terms of the area under the receiver operating curve (AUC) and classification accuracy (Acc). Monte Carlo simulations were run to generate datasets (n = 10) on which logistic regression was conducted using a constant ratio of 80:20 (measurement:algorithm training), followed by algorithm validation by WEKA. The proposed algorithm can classify the 1000 kDa vs. 100 kDa (AUC > 0.8) correctly, but discrimination is weak for the 100 kDa vs. 50 kDa (AUC < 0.7), the latter being attributed to the instrument accuracy errors below 5 nm. As indicated by the results of the cross-validation study, a test size equivalent to 70% (AUCtapping = 0.8341 ± 0.0519, Acctapping = 76.8% ± 5.9%) and 80% (AUCfluid = 0.7614 ± 0.0314, Acctfluid = 76.2% ± 1.0%) of the training sets for the tapping and fluid modes are needed for correct classification, resulting in predicted reduction of scan times.