Kiejin Lee

Prof. Kiejin Lee


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2008 in Review of Scientific Instruments
Verified
Journal Article
Closed access
JKJongchul Kim
Jongchul Kim
ABArsen Babajanyan
Arsen Babajanyan
AHArtur Hovsepyan
Artur Hovsepyan
KLKiejin Lee
Kiejin Lee
BFBarry Friedman
Barry Friedman
We report a near-field microwave biosensor based on a dielectric resonator to detect glucose concentration. A microwave biosensor with a high Q dielectric resonator allows observation of the small variation of the glucose concentration by measuring the shift of the resonance frequency and the microwave reflection coefficient S11. We observed the concentration of glucose with a detectable resolution up to 5mg∕ml at an operating frequency of about f=1.68GHz. The change in the glucose concentration is directly related to the change in the reflection coefficient due to the electromagnetic interaction between the dielectric resonator and the glucose solution.

13 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
LOLevon Odabashyan
Levon Odabashyan
ABArsen Babajanyan
Arsen Babajanyan
ZBZhirayr Baghdasaryan
Zhirayr Baghdasaryan
SKSeungwan Kim
Seungwan Kim
JKJongchel Kim
Jongchel Kim
KLKiejin Lee
Kiejin Lee
We developed a microwave glucose sensor based on the modified first-order Hilbert curve design and measured glucose concentration in aqueous solutions by using a real-time microwave near-field electromagnetic interaction technique. We observed S21 transmission parameters of the sensor at resonant frequencies depend on the glucose concentration. We could determine the glucose concentration in the 0–250 mg/dL concentration range at an operating frequency of near 6 GHz. The measured minimum detectable signal was 0.0156 dB/(mg/dL) and the measured minimum detectable concentration was 1.92 mg/dL. The simulation result for the minimum detectable signal and the minimum detectable concentration was 0.0182 dB/(mg/dL) and 1.65 mg/dL, respectively. The temperature instability of the sensor for human glycemia in situ measurement range (27–34 °C for fingers and 36–40 °C for body temperature ranges) can be improved by the integration of the temperature sensor in the microwave stripline platform and the obtained data can be corrected during signal processing. The microwave signal–temperature dependence is almost linear with the same slope for a glucose concentration range of 50–150 mg/dL. The temperature correlation coefficient is 0.05 dB/°C and 0.15 dB/°C in 27–34 °C and 36–40 °C temperature range, respectively. The presented system has a cheap, easy fabrication process and has great potential for non-invasive glucose monitoring.

29 December 2010 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
ABArsen Bababjanyan
Arsen Bababjanyan
HMHarutyun Melikyan
Harutyun Melikyan
SKSeungwan Kim
Seungwan Kim
JKJongchel Kim
Jongchel Kim
KLKiejin Lee
Kiejin Lee
BFBarry Friedman
Barry Friedman
We measured the glucose concentration by using the real-time electromagnetic interaction between probe-tip and glucose solution using a microwave biosensor. The microwave biosensor, consisting of a dielectric resonator coupled to the probe-tip, allows observation of the small variation of the glucose concentration changes in the ranges of 0–300 mg/ml by measuring the microwave reflection coefficientS11. We could observe the concentration of glucose with a detectable resolution up to 1 mg/ml at an operating frequency of aboutf=4-5 GHz. The change of the glucose concentration is directly related to the change of the reflection coefficient due to the electromagnetic interaction between the microwave resonator and the glucose solution. The operational principal is explained by the plane-wave solution model. The measured signal-to-noise ratio was about 37 dB, and the minimum detectible signal was about 0.003 dB/(mg/ml). A glucose biosensor using a microwave resonator with probe provides a unique approach for glucose real-time monitoring.

22 December 2016 in Scientific Reports
Verified
Journal Article
Open access
HLHanju Lee
Hanju Lee
SAShant Arakelyan
Shant Arakelyan
BFBarry Friedman
Barry Friedman
KLKiejin Lee
Kiejin Lee
A high resolution imaging of the temperature and microwave near field can be a powerful tool for the non-destructive testing of materials and devices. However, it is presently a very challenging issue due to the lack of a practical measurement pathway. In this work, we propose and demonstrate experimentally a practical method resolving the issue by using a conventional CCD-based optical indicator microscope system. The present method utilizes the heat caused by an interaction between the material and an electromagnetic wave, and visualizes the heat source distribution from the measured photoelastic images. By using a slide glass coated by a metal thin film as the indicator, we obtain optically resolved temperature, electric, and magnetic microwave near field images selectively with a comparable sensitivity, response time, and bandwidth of existing methods. The present method provides a practical way to characterize the thermal and electromagnetic properties of materials and devices under various environments.

23 July 2003 in Review of Scientific Instruments
Verified
Journal Article
Closed access
MKMyung Sik Kim
Myung Sik Kim
SKSonghui Kim
Songhui Kim
JKJooyoung Kim
Jooyoung Kim
KLKiejin Lee
Kiejin Lee
BFBarry Friedman
Barry Friedman
JLJaekwang Lee
Jaekwang Lee

4 August 2003 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
JKJooyoung Kim
Jooyoung Kim
MKMyungsick Kim
Myungsick Kim
HKHyun Kim
Hyun Kim
DSDoohee Song
Doohee Song
KLKiejin Lee
Kiejin Lee
BFBarry Friedman
Barry Friedman
We fabricated a near-field scanning microwave microscope (NSMM) using a hybrid tip combining a reduced length of the tapered part with a small apex. In order to understand the function of the probe, we fabricated three different tips using a conventional chemical etching technique and observed three different NSMM images for patterned Cr films on glass substrates. These probe tips were coupled to a high-quality dielectric resonator at an operating frequency f=4.46 GHz. By using the hybrid tip, we demonstrated an improved, high-contrast NSMM image of lambda phage DNA on a glass substrate.