Parallel magnetic resonance imaging (pMRI) using multichannel receiver coils has emerged as an effective tool to reduce imaging time in various applications. However, the issue of accurate estimation of coil sensitivities has not been fully addressed, which limits the level of speed enhancement achievable with the technology. The self‐calibrating (SC) technique for sensitivity extraction has been well accepted, especially for dynamic imaging, and complements the common calibration technique that uses a separate scan. However, the existing method to extract the sensitivity information from the SC data is not accurate enough when the number of data is small, and thus erroneous sensitivities affect the reconstruction quality when they are directly applied to the reconstruction equation. This paper considers this problem of error propagation in the sequential procedure of sensitivity estimation followed by image reconstruction in existing methods, such as sensitivity encoding (SENSE) and simultaneous acquisition of spatial harmonics (SMASH), and reformulates the image reconstruction problem as a joint estimation of the coil sensitivities and the desired image, which is solved by an iterative optimization algorithm. The proposed method was tested on various data sets. The results from a set of in vivo data are shown to demonstrate the effectiveness of the proposed method, especially when a rather large net acceleration factor is used. Magn Reson Med 57:1196–1202, 2007.
In parallel imaging, the signal‐to‐noise ratio (SNR) of sensitivity encoding (SENSE) reconstruction is usually degraded by the ill‐conditioning problem, which becomes especially serious at large acceleration factors. Existing regularization methods have been shown to alleviate the problem. However, they usually suffer from image artifacts at high acceleration factors due to the large data inconsistency resulting from heavy regularization. In this paper, we propose Bregman iteration for SENSE regularization. Unlike the existing regularization methods where the regularization function is fixed, the method adaptively updates the regularization function using the Bregman distance at different iterations, such that the iteration gradually removes the aliasing artifacts and recovers fine structures before the noise finally comes back. With a discrepancy principle as the stopping criterion, our results demonstrate that the reconstructed image using Bregman iteration preserves both sharp edges lost in Tikhonov regularization and fines structures missed in total variation (TV) regularization, while reducing more noise and aliasing artifacts. Magn Reson Med 61:145–152, 2009.