Shiyang Li

Shiyang Li


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Ultrasonics
Verified
Journal Article
Closed access
SLShiyang Li
Shiyang Li
WOWenchu Ou
Wenchu Ou
MYMing Yang
Ming Yang
CGChao Guo
Chao Guo
CLCunyue Lu
Cunyue Lu
JHJunhui Hu
Junhui Hu

12 September 2013 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
SLShiyang Li
Shiyang Li
LZLimei Zheng
Limei Zheng
WJWenhua Jiang
Wenhua Jiang
RSRaffi Sahul
Raffi Sahul
VGVenkatraman Gopalan
Venkatraman Gopalan
WCWenwu Cao
Wenwu Cao
The most difficult task in the characterization of complete set material properties for piezoelectric materials is self-consistency. Because there are many independent elastic, dielectric, and piezoelectric constants, several samples are needed to obtain the full set constants. Property variation from sample to sample often makes the obtained data set lack of self-consistency. Here, we present a method, based on pulse-echo ultrasound and inverse impedance spectroscopy, to precisely determine the full set physical properties of piezoelectric materials using only one small sample, which eliminated the sample to sample variation problem to guarantee self-consistency. The method has been applied to characterize the [001]C poled Mn modified 0.27Pb(In1/2Nb1/2)O3-0.46Pb(Mg1/3Nb2/3)O3-0.27PbTiO3 single crystal and the validity of the measured data is confirmed by a previously established method. For the inverse calculations using impedance spectrum, the stability of reconstructed results is analyzed by fluctuation analysis of input data. In contrast to conventional regression methods, our method here takes the full advantage of both ultrasonic and inverse impedance spectroscopy methods to extract all constants from only one small sample. The method provides a powerful tool for assisting novel piezoelectric materials of small size and for generating needed input data sets for device designs using finite element simulations.

6 May 2013 in Applied Physics Letters
Verified
Journal Article
Closed access
SLShiyang Li
Shiyang Li
WJWenhua Jiang
Wenhua Jiang
LZLimei Zheng
Limei Zheng
WCWenwu Cao
Wenwu Cao
We report a face-shear mode ultrasonic motor (USM) made of [011]c poled Zt ± 45° cut 0.24Pb(In1/2Nb1/2)O3-0.46Pb(Mg1/3Nb2/3)O3-0.30PbTiO3 single crystal, which takes advantage of the extremely large d36 = 2368 pC/N. This motor has a maximum no-load linear velocity of 182.5 mm/s and a maximum output force of 1.03 N under the drive of Vp = 50 V, f = 72 kHz. Compared with the k31 mode USM made of Pb(Zr,Ti)O3 (PZT), our USM has simpler structure, lower driving frequency, much higher electromechanical coupling factor, and twice power density. This USM can be used for low frequency operation as well as cryogenic actuation with a large torque.

3 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ZFZhiwei Fang
Zhiwei Fang
TYTianyue Yang
Tianyue Yang
YZyuanfei zhu
yuanfei zhu
SLShiyang Li
Shiyang Li
YMYang Ming
Yang Ming
Nonlinearity and resonance frequency shift make it difficult to control the operation of the traveling-wave ultrasonic motors (TWUSMs) in a wide velocity and load range. In this paper, a velocity control scheme based on the stator vibration amplitude and the parallel resonance frequency (VCBVF) of TWUSMs is proposed. Then, the stator vibration amplitude (SVA) and parallel resonance frequency ( f p ) are detected by a transformer ratio-arm bridge. Based on the linear relationship between the velocity and the SVA of TWUSMs, the proposed scheme achieves the control of the mechanical loop and the electrical loop. The linear relationship between the velocity and the SVA makes the mechanical loop achieve the target velocity efficiently, according to the SVA, and the electrical loop could provide the target SVA quickly. Experimental results show that the response time of velocity is 3–4 ms under different load torques and the overshoot is less than 22%. In addition, the proposed scheme improves the efficiency of TWUSMs due to f p tracking. Due to directing the SVA control, the proposed scheme can heighten the velocity response and the load adaptability of TWUSMs, and promote the application of TWUSMs under various conditions.

6 June 2016 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
SLShiyang Li
Shiyang Li
ZCZhaojiang Chen
Zhaojiang Chen
WCWenwu Cao
Wenwu Cao
Polarization switching and associated electromechanical property changes at 3.0 MHz were investigated with and without a direct current (dc) bias for [001]c poled 0.70Pb(Mg1/3Nb2/3)O3-0.30PbTiO3 single crystal. The results showed that the coercive field under a bipolar pulse at 3.0 MHz is 2.75 times as large as conventional defined Ec (2.58 kV/cm at 0.1 Hz), and a dc bias can further enlarge the driving field. Our results point to an innovative transducer operating mechanism at high frequencies since one could drive the crystal under much larger fields at high frequencies to produce much stronger signals from a small array element for deeper penetration imaging.

28 February 2014 in Sensors
Verified
Journal Article
Open access
PDF file
LYLin Ye
Lin Ye
YMYang Ming
Yang Ming
LXLiang Xu
Liang Xu
XZXiaoqi Zhuang
Xiaoqi Zhuang
ZDzhaopeng Dong
zhaopeng Dong
SLShiyang Li
Shiyang Li
Using the finite element method (FEM) and particle swarm optimization (PSO), a nonlinearity analysis based on parameter optimization is proposed to design an inductive angle sensor. Due to the structure complexity of the sensor, understanding the influences of structure parameters on the nonlinearity errors is a critical step in designing an effective sensor. Key parameters are selected for the design based on the parameters’ effects on the nonlinearity errors. The finite element method and particle swarm optimization are combined for the sensor design to get the minimal nonlinearity error. In the simulation, the nonlinearity error of the optimized sensor is 0.053% in the angle range from −60° to 60°. A prototype sensor is manufactured and measured experimentally, and the experimental nonlinearity error is 0.081% in the angle range from −60° to 60°.