Nonlinearity and resonance frequency shift make it difficult to control the operation of the traveling-wave ultrasonic motors (TWUSMs) in a wide velocity and load range. In this paper, a velocity control scheme based on the stator vibration amplitude and the parallel resonance frequency (VCBVF) of TWUSMs is proposed. Then, the stator vibration amplitude (SVA) and parallel resonance frequency ( ) are detected by a transformer ratio-arm bridge. Based on the linear relationship between the velocity and the SVA of TWUSMs, the proposed scheme achieves the control of the mechanical loop and the electrical loop. The linear relationship between the velocity and the SVA makes the mechanical loop achieve the target velocity efficiently, according to the SVA, and the electrical loop could provide the target SVA quickly. Experimental results show that the response time of velocity is 3–4 ms under different load torques and the overshoot is less than 22%. In addition, the proposed scheme improves the efficiency of TWUSMs due to tracking. Due to directing the SVA control, the proposed scheme can heighten the velocity response and the load adaptability of TWUSMs, and promote the application of TWUSMs under various conditions.
The consistency of the two-phase mode responses is essential to ensure the mechanical performance and stability of traveling-wave ultrasonic motors. Due to the asymmetry of the stator, inevitable manufacturing errors, or imbalance of the excitation voltages, the amplitudes of the two-phase standing waves cannot be exactly the same, resulting in unstable operating of USM. To improve the stability of the motor and decrease the velocity fluctuation, a closed-loop velocity control scheme considering two-phase consistency compensation based on the vibration amplitude of the stator is proposed. This scheme is implemented under the framework of the stator vibration amplitude-based velocity control and parallel resonance frequency tracking (VCBVF). Based on the relationship between the velocity and stator vibration amplitude (SVA), two-phase excitation signals are adjusted individually and simultaneously. Compared with the single-phase feedback VCBVF control scheme, experimental results show that the proposed scheme can reduce the overshoot from 17.50% to 6.90% and velocity fluctuations from 7.69 rpm to 2.40 rpm, under different load torques. The proposed scheme can compensate for the two-phase electrical inconsistency and improve the velocity stability and output power of motor operation under various conditions.
Frequency tracking and amplitude control are essential for piezoelectric transducers. Frequency tracking ensures the piezoelectric transducer operates at the resonant frequency for maximum power output, and amplitude control regulates the mechanical motion of the output. This paper presents a novel driver based on a push–pull inverter for piezoelectric transducers. The proposed driver realizes the frequency tracking and amplitude control scheme by a voltage sensing bridge in the case of transformer secondary matching, guaranteeing automatic frequency tracking and precise mechanical functions regardless of environmental and load variations. The proposed scheme is verified by the ultrasonic scalpel and the ultrasonic motor (USM). The experimental results show that this scheme reduces the build-up time from 10 ms to 3 ms and loaded frequency variations from 250 Hz to 200 Hz. In addition, the amplitude control performance was further observed on USM for various loads. The overshoot is less than 5.4% under different load torques. Therefore, the proposed scheme improves the load adaptability and stability of piezoelectric transducers and promotes the application of piezoelectric transducers under various conditions.
Significant variation in impedance under a wide range of loads increases the difficulty of frequency tracking and vibration control in high-power piezoelectric systems (HPPSs). This paper proposed a wide operating range driving and control scheme for HPPSs. We systematically analyzed the impedance characteristics and deduced the load optimization frequency. In order to provide sufficient drive capability, the inverter combined with an LC matching circuit is configured. With the aid of a transformer ratio arm bridge (TRAB) combined with a proposed pulse-based phase detector (PBPD), the proposed scheme can control the vibration amplitude and keep parallel resonance status under a wide range of loads. Experiments conducted under actual operating conditions verify the feasibility of the proposed scheme under the modal resistance range from 7.40 to 500 Ω and the vibration range from 20% to 100%. Moreover, with the aid of a laser displacement sensor, our scheme is verified to have a vibration amplitude control accuracy better than 2% over a tenfold load variation. This research could be helpful for the driving and control of HPPSs operating in a wide range.
25 June 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Accurate and fast velocity feedback signal is essential for the velocity control of ultrasonic motors (USMs). However, the low operating velocity of USMs results in a long velocity detection dead time (VDDT) of incremental encoders, which seriously restricts the dynamic control performance of USMs. Therefore, this article presents a super-resolution velocity control (SRVC) scheme based on the velocity reconstruction for the USM. First, the mathematical model of the USM is derived from the mechanical characteristics and the electromechanical coupling characteristics. Then, the velocity reconstruction method is proposed by combining the model estimated velocity and the encoder measured velocity. The closed-loop control scheme using the reconstructed velocity is implemented by a self-designed driving circuit. Experimental results show the velocity reconstruction method not only can break through the limitation of the encoder resolution to reduce the VDDT but also has a high-velocity accuracy. Furthermore, compared with the existing encoder-based control scheme, the proposed SRVC scheme has a faster velocity response under different loads.
Background: In recent years, intravascular micro-axial blood pumps have been increasingly used in the treatment of patients with cardiogenic shock. The flow rate of such blood pumps requires adjustment based on the patient’s physiological condition. Compared to a stable flow state with fixed rotation speed, adjusting the speed of blood pump impeller to alter flow rate may lead to additional hemolysis. This study aimed at elucidating the relationship between adjusting interval of a blood pump’s impeller speed and the hemolysis index. Methods: By comparing simulation results with P-Q characteristic curves of the blood pump measured by experiments, the accuracy of the blood pump flow field simulation model was confirmed. In this study, a drainage tube was employed as the device analogous to an intravascular micro-axial blood pump for achieving similar shear stress levels and residence times. The hemolysis finite element prediction method based on a power-law model was validated through hemolysis testing of porcine blood flow through the drainage tube. The validated models were subsequently utilized to investigate the impact of impeller speed adjusting intervals on hemolysis in the blood pump. Results: Compared to steady flow, the results demonstrate that the hemolysis index increased to 6.3% when changing the blood pump flow rate from 2 L/min to 2.5 L/min by adjusting the impeller speed within 0.072 s. Conclusions: An adjustment time of impeller speed longer than 0.072 s can avoid extra hemolysis when adjusting the intravascular micro-axial blood pump flow rate from 2 L/min to 2.5 L/min.