To improve the stability and adaptability of the voltage measurement based on the E-field (electric field) integral method, in this paper we introduce a new method for the contactless voltage measurement of the overhead lines. The method adopts the node parameter reconstruction technology, which is based on the Gauss–Chebyshev algorithm. In order to achieve high-quality E-field detection at the reconstructed node position, we designed a novel D-dot sensor with parallel distributed electrodes. A Maxwell simulation model of multi-level voltages of the overhead lines was carried out to determine a comprehensive criterion of the reconstruction factors. The simulation employed a three-phase overhead line experiment platform to calculate and measure the distribution and the changing trend of the E-field. The deviations of the voltage measurement were reduced at a significantly low level within 0.4%. The result of the simulation demonstrates that the method optimizes sensor distribution by reconstructing node parameters, which enables the system to have high accuracy and reliability on the contactless voltage measurement of the overhead lines.
Electric field numerical integration algorithms can realize the non-contact measurement of transmission line voltage effectively. Although there are many electric field numerical integration algorithms, lack of a comprehensive comparison of accuracy and stability among various algorithms results in difficulties in evaluating the measurement results of various algorithms. Therefore, this paper presents the G-L (Gauss–Legendre) algorithm, the I-G-L (improved Gauss–Legendre) algorithm, and the I-G-C (improved Gauss–Chebyshev) algorithm and proposes a unified error propagation model of the derived algorithms to assess the accuracy of each integration method by considering multiple error sources. Moreover, evaluation criteria for the uncertainty of transmission line voltage measurement are proposed to analyze the stability and reliability of these algorithms. A simulation model and experiment platform were then constructed to conduct error propagation and uncertainty analyses. The results show that the G-L algorithm had the highest accuracy and stability in the scheme with five integral nodes, for which the simulation error was 0.603% and the relative uncertainty was 2.130%. The I-G-L algorithm was more applicable due to the smaller number of integral nodes required, yet the algorithm was less stable in achieving the same accuracy as the G-L algorithm. In addition, the I-G-C algorithm was relatively less accurate and stable in voltage measurement.
11 March 2022 in IEEE Transactions on Instrumentation and Measurement
Contactless overvoltage measurement sensor has good foreground in the application of the power system, and however, the difference in the installation position of the sensor will directly affect the stability of the measurement system. Therefore, it is essential to improve the overall measurement effect by selecting an appropriate measuring point. In this article, first, we proposed a new self-decoupling method based on the simplified matrix with the position parameters of the measuring point and applied it in the measurement of three-phase transient overvoltage. Then, we obtained the 3-D electric field ( $E$ -field) distribution characteristic under the different simulated overvoltage signals and preliminarily analyzed the measuring effect of the various measuring points distributed in the axial and radial direction of the overhead line. Furthermore, we proposed the gradient optimizing method with a calculation and analysis process for the selection of the measuring point. Finally, taking the three-phase horizontal distributed transmission lines as an example, we calculated the voltage coefficient matrix at various selected points, estimated the uncertainty contributions, and accomplished the test through the overvoltage experimental platform. From the result, the relative amplitude error of the overvoltage signal measured by the sensor installed at the optimal measuring point is less than 3.50%, the relative expanded uncertainty of the test at the optimal point is about 8.74%, and the values are much smaller than those of other measuring points, which proved the effectiveness of the proposed method.
14 July 2021 in IEEE Transactions on Power Delivery
It is essential to carry out an AC voltage withstand test after GIS extension and maintenance. At present, the common methods of GIS AC withstand test include double isolation gap, reduce the test voltage, and narrow test range. These methods generally have some defects: such as complex test processes, all bus de-energized, some apparatus failed to test, unreliable test results and so on. This paper presents a distinctive GIS AC voltage withstand test method. The method controls the phase-frequency parameters of the test voltage so that it maintains the same phase-frequency relationships as the in-service bus voltage during the process of testing. In this situation, the GIS can carry out an energized AC voltage withstand test. The process of AC withstand voltage test method based on phase-frequency control (PFC) is introduced in detail, and the feasibility of this method is verified. The phase difference margin of the PFC method is optimized through simulation and numerical calculation, and a variety of protection measures are proposed to ensure the safety of the test process. The proposed PFC AC voltage withstand test method will not affect the in-service bus and has great practical application value for the field GIS AC voltage withstand test.0F.
29 July 2021 in IEEE Transactions on Power Delivery
The Potential Transformer (PT) plays an important role in the measurement and monitoring of the power system. The accurate modeling of the PT is very important but not yet perfect. The stray capacitance will have a non-negligible effect on the performance of a PT. However, the influence of stray capacitance is rarely considered in existing models, which makes the broadband simulation performance weak and provides limited references in engineering. In this paper, a calculation method of PT stray capacitance is proposed to analyze the performance of the PT at different frequencies and extract the capacitive current of the PT port. This paper used a non-destructive method to obtain the test data of a PT, calculated the value of the stray capacitance, and drew the hysteresis loops of the iron core. A corresponding simulation model was established to predict the PT performance at different frequencies. The simulation results are in good agreement with the experimental data, which proves the accuracy of the modeling parameters. The data processing logic is clear and is easy to be simplified by programming, which makes it promising in engineering.
15 April 2021 in IEEE Transactions on Instrumentation and Measurement
Most of the available overvoltage sensors are too sensitive to the installation angle and inducing direction. Even a slight angular deflection will cause a nonnegligible error to the measurement. To reduce the impact caused by angular deflection, in this article, we propose a new spherical six-electrode overvoltage sensor to improve the measuring accuracy and stability. First, we presented the 3-D electric field ( $E$ -field) coupling mechanism, vector synthesis method, design, and output properties of the proposed sensor. Second, we obtained the relationship between the structural parameters and the equivalent capacitance by the finite-element method (FEM). Finally, we completed the steady-state test, transient test, and 3-D angular deflection test. From the results, the sensor has a broad bandwidth of 1.2 MHz, a phase error of less than 1.8°, and good linearity of the output signals. In the case of 3-D angular deviations, the mean relative error (MRE) of the sensor is lower than 2.55%, with a maximum standard deviation (SD) of 0.088%, which proves that the output of the proposed sensor is well consistent with the overvoltage signal, and its accuracy is almost immune to the angular deflection.