An experimental study is conducted to determine the influence of secondary reinforcement on the behaviour of corbels fabricated with three different types of high-performance fiber-reinforced cementitious composites, including engineered cementitious concrete (ECC); high-performance steel fiber-reinforced composite (HPSFRC); and hybrid fiber-reinforced composite (HyFRC). Two shear span-to-depth ratios (a/d = 0.75 and 1.0) are explored. The mechanical properties of the composites in terms of tensile, compressive, and flexural strengths are investigated. Next, the structural behaviour of the high-performance cementitious composite corbels in terms of ultimate load capacity, ductility, and failure modes under the three-point bending test are investigated. The secondary reinforcement is proven to significantly affect stiffness and ultimately load capacity of all three high-performance composite corbels with an aspect ratio of 0.75. However, the secondary reinforcement was more impactful for the HPSFRC corbels, with 51% increase of ultimate strength. Moreover, in terms of damage, fewer cracks occurred in ECC corbels. HPSFRC corbels displayed the highest level of ductility and deformation capacity compared to the other specimens. The results were comparatively analyzed against the predicted results using truss and plastic truss models which provided relatively reliable shear strength.
The increasing need for sustainable alternatives to traditional concrete in Steel-Concrete-Steel (SCS) sandwich panels has led to the exploration of Engineered Geopolymer Composites (EGCs). While the material properties of EGCs are promising, the specific shear transfer mechanisms of headed-stud connectors within EGC panels represent a critical knowledge gap. To address this, this study presents a novel, comprehensive experimental evaluation of headed-stud shear behaviour in EGC, systematically comparing its performance against conventional normal concrete (NC) and high-performance engineered cementitious composite (ECC). Push-out tests were conducted, varying core materials, connector diameters (12mm, 16mm, 18mm), embedment depths, and connector counts. Results show EGC exhibits superior shear performance compared to NC, achieving a 10% increase in ultimate load for bolted connections and a 35% increase for single stud pairs. Furthermore, EGC demonstrates comparable performance relative to ECC in certain configurations, with double stud pairs in EGC achieving 166 kN ultimate load, only a 7% reduction compared to ECC. EGC consistently displayed ductile failure modes, enhancing structural integrity. Existing analytical models were also validated, highlighting the importance of material-specific model selection. This study confirms EGC's potential as a robust and sustainable alternative for SCS panels.