Xihui Mu

Dr. Xihui Mu


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2022 in Analytica Chimica Acta
Verified
Journal Article
Closed access
ZXZihao Xie
Zihao Xie
SFShasha Feng
Shasha Feng
FPFubin Pei
Fubin Pei
MXMingzhu Xia
Mingzhu Xia
QHQingli Hao
Qingli Hao
XMXihui Mu
Xihui Mu

13 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
LFLirui Fan
Lirui Fan
BDBin Du
Bin Du
FPFubin Pei
Fubin Pei
WHWei Hu
Wei Hu
AGAijiao Guo
Aijiao Guo
WTWenyuan Tan
Wenyuan Tan
In this paper, a core-shell based on the Fe3O4@SiO2@Au nanoparticle amplification technique for a surface plasmon resonance (SPR) sensor is proposed. Fe3O4@SiO2@AuNPs were used not only to amplify SPR signals, but also to rapidly separate and enrich T-2 toxin via an external magnetic field. We detected T-2 toxin using the direct competition method in order to evaluate the amplification effect of Fe3O4@SiO2@AuNPs. A T-2 toxin–protein conjugate (T2-OVA) immobilized on the surface of 3-mercaptopropionic acid-modified sensing film competed with T-2 toxin to combine with the T-2 toxin antibody–Fe3O4@SiO2@AuNPs conjugates (mAb-Fe3O4@SiO2@AuNPs) as signal amplification elements. With the decrease in T-2 toxin concentration, the SPR signal gradually increased. In other words, the SPR response was inversely proportional to T-2 toxin. The results showed that there was a good linear relationship in the range of 1 ng/mL~100 ng/mL, and the limit of detection was 0.57 ng/mL. This work also provides a new possibility to improve the sensitivity of SPR biosensors in the detection of small molecules and in disease diagnosis.

15 May 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
LFLirui Fan
Lirui Fan
BDBin Du
Bin Du
FPFubin Pei
Fubin Pei
WHWei Hu
Wei Hu
SFShasha Feng
Shasha Feng
XMXihui Mu
Xihui Mu
Since the global outbreak of coronavirus disease 2019 (COVID-19), it has spread rapidly around the world. The nucleocapsid (N) protein is one of the most abundant SARS-CoV-2 proteins. Therefore, a sensitive and effective detection method for SARS-CoV-2 N protein is the focus of research. Here, we developed a surface plasmon resonance (SPR) biosensor based on the dual signal-amplification strategy of Au@Ag@Au nanoparticles (NPs) and graphene oxide (GO). Additionally, a sandwich immunoassay was utilized to sensitively and efficiently detect SARS-CoV-2 N protein. On the one hand, Au@Ag@Au NPs have a high refractive index and the capability to electromagnetically couple with the plasma waves propagating on the surface of gold film, which are harnessed for amplifying the SPR response signal. On the other hand, GO, which has the large specific surface area and the abundant oxygen-containing functional groups, could provide unique light absorption bands that can enhance plasmonic coupling to further amplify the SPR response signal. The proposed biosensor could efficiently detect SARS-CoV-2 N protein for 15 min and the detection limit for SARS-CoV-2 N protein was 0.083 ng/mL, with a linear range of 0.1 ng/mL~1000 ng/mL. This novel method can meet the analytical requirements of artificial saliva simulated samples, and the developed biosensor had a good anti-interference capability.

26 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
LSLiu Shuai
Liu Shuai
TZTong Zhaoyang
Tong Zhaoyang
XMXihui Mu
Xihui Mu
BLBing Liu
Bing Liu
BDBin Du
Bin Du
CGChuan Gao
Chuan Gao
For the convenience of fast measurement in the outdoor environment, a portable electrochemiluminescence biosensor with the screen-printed electrode as the reaction center was developed, which possesses the characteristics of high sensitivity, small scale, simplified operation and so on, and has been used for in situ detection of abrin. First, combining with magnetic separation technique, the “biotin-avidin” method was used to immobilize the polyclonal antibody (pcAb) on the magnetic microspheres surface as the capture probe. Secondly, the Ru(bpy)32+-labeled monoclonal antibody (mcAb) was used as the specific electrochemiluminescence signal probe. Then, the “mcAb-toxin-pcAb” sandwich model was built to actualize the quantitative detection of abrin on the surface of the screen-printed electrode. The linear detection range was 0.5–1000 ng/mL; the regression equation was Y = 89.251lgX + 104.978 (R = 0.9989, n = 7, p < 0.0001); and the limit of detection (LOD) was 0.1 ng/mL. The sensing system showed high sensitivity, excellent specificity and good anti-interference ability, and could be used for the analysis of trace abrin in various environmental samples with good recovery and reproducibility. Compared with the traditional electrochemiluminescence sensing device, its miniaturization and portability gives it potential to satisfy the requirement of in situ detection.

4 January 2022 in Micro & Nano Letters
Verified
Journal Article
Open access
PDF file
CJChunying Jiang
Chunying Jiang
XMXihui Mu
Xihui Mu
BDBin Du
Bin Du
ZTZhaoyang Tong
Zhaoyang Tong
With the rapid spread and proliferation of Coronavirus disease 2019 (COVID‐19) worldwide, highly pathogenic severe acute respiratory syndrome coronavirus type 2 (SARS‐CoV‐2) seriously threatens human life and health. The rapid and accurate abilities to detect SARS‐CoV‐2 have become the key to prevent and control COVID‐19. Electrochemical sensors have shown broad application prospects in biological detection because of the advantages of high sensitivity, specificity, and short time‐consuming. This review summarizes the application of electrochemical biosensors in detecting SARS‐CoV‐2 and discusses prospects for developing direction in this field.

9 February 2015 in Sensors
Verified
Journal Article
Open access
PDF file
XMXihui Mu
Xihui Mu
TZTong Zhaoyang
Tong Zhaoyang
QHQibin Huang
Qibin Huang
BLBing Liu
Bing Liu
ZLZhiwei Liu
Zhiwei Liu
FWFenwei Wang
Fenwei Wang
In this research, super-paramagnetic Fe3O4 nanoparticles (magnetic particles) were coated with Staphylococcus protein A (SPA) and coupled with polyclonal antibody (pcAb) to construct magnetic capturing probes, and HRP-conjugated phage antibody was then used as specific detecting probe to design a labeled immunosensor for trace detection of Staphylococcus aureus enterotoxin B (SEB). The linear detection range of the sensor was 0.008~125 µg/L, the regression equation was Y = 0.487X + 1.2 (R = 0.996, N = 15, p < 0.0001), the limit of detection (LOD) was 0.008 µg/L, and the limit of quantification (LOQ) was 0.008 µg/L. HRP-conjugated phage antibody, SPA and magnetic particles can enhance the sensitivity 4-fold, 3-fold and 2.6-fold higher, respectively. Compared with conventional double-antibody sandwich ELISA, the detection sensitivity of the sensor was 31-fold higher resulting from the integrated amplifying effect. The immunosensor integrates the unique advantages of SPA-oriented antibody as magnetic capturing probe, HRP-conjugated phage antibody as detecting probe, magnetic separation immunoassay technique, and several other advanced techniques, so it achieves high sensitivity, specificity and interference-resistance. It is proven to be well suited for analysis of trace SEB in various environmental samples with high recovery rate and reproducibility.