Liu Shuai

Mr. Liu Shuai


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
LSLiu Shuai
Liu Shuai
TZTong Zhaoyang
Tong Zhaoyang
XMXihui Mu
Xihui Mu
BLBing Liu
Bing Liu
BDBin Du
Bin Du
CGChuan Gao
Chuan Gao
For the convenience of fast measurement in the outdoor environment, a portable electrochemiluminescence biosensor with the screen-printed electrode as the reaction center was developed, which possesses the characteristics of high sensitivity, small scale, simplified operation and so on, and has been used for in situ detection of abrin. First, combining with magnetic separation technique, the “biotin-avidin” method was used to immobilize the polyclonal antibody (pcAb) on the magnetic microspheres surface as the capture probe. Secondly, the Ru(bpy)32+-labeled monoclonal antibody (mcAb) was used as the specific electrochemiluminescence signal probe. Then, the “mcAb-toxin-pcAb” sandwich model was built to actualize the quantitative detection of abrin on the surface of the screen-printed electrode. The linear detection range was 0.5–1000 ng/mL; the regression equation was Y = 89.251lgX + 104.978 (R = 0.9989, n = 7, p < 0.0001); and the limit of detection (LOD) was 0.1 ng/mL. The sensing system showed high sensitivity, excellent specificity and good anti-interference ability, and could be used for the analysis of trace abrin in various environmental samples with good recovery and reproducibility. Compared with the traditional electrochemiluminescence sensing device, its miniaturization and portability gives it potential to satisfy the requirement of in situ detection.

28 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
BDBin Du
Bin Du
TZTong Zhaoyang
Tong Zhaoyang
XMXihui Mu
Xihui Mu
JXJianjie Xu
Jianjie Xu
LSLiu Shuai
Liu Shuai
ZQZhi-mei Qi
Zhi-mei Qi
An optical waveguide (OWG) sensor was developed for real-time detection of diethyl chlorophosphate (DCP) vapor, which is a typical simulant for organophosphorus pesticides and chemical weapon agents. Silica gel, crystal violet (CV), and potassium ion-exchange (PIE) OWG were used to fabricate the sensor’s device. In the real-time detection of the DCP vapor, the volume fraction of DCP vapor was recorded to be as low as 1.68 × 10−9. Moreover, the detection mechanism of CV-SiO2 gel film coated the PIE OWG sensor for DCP, which was evaluated by absorption spectra. These results demonstrated that the change of output light intensity of the OWG sensor significantly increased with the augment of the DCP concentration. Repeatability as well as selectivity of the sensors were tested using 0.042 × 10−6 and 26.32 × 10−6 volume fraction of the DCP vapor. No clear interference with the DCP detection was observed in the presence of other common solvents (e.g., acetone, methanol, dichloromethane, dimethylsulfoxide, and tetrahydrofuran), benzene series (e.g., benzene, toluene, chlorobenzene, and aniline), phosphorus-containing reagents (e.g., dimethyl methylphosphonate and trimethyl phosphate), acid, and basic gas (e.g., acetic acid and 25% ammonium hydroxide), which demonstrates that the OWG sensor could provide real-time, fast, and accurate measurement results for the detection of DCP.

21 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CJChunying Jiang
Chunying Jiang
XMXihui Mu
Xihui Mu
LSLiu Shuai
Liu Shuai
ZLZhiwei Liu
Zhiwei Liu
BDBin Du
Bin Du
JXJianjie Xu
Jianjie Xu
To satisfy the need to develop highly sensitive methods for detecting the severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) and further enhance detection efficiency and capability, a new method was created for detecting SARS-CoV-2 of the open reading frames 1ab (ORF1ab) target gene by a electrochemiluminescence (ECL) biosensor based on dual-probe hybridization through the use of a detection model of “magnetic capture probes—targeted nucleic acids—Ru(bpy)32+ labeled signal probes”. The detection model used magnetic particles coupled with a biotin-labeled complementary nucleic acid sequence of the SARS-CoV-2 ORF1ab target gene as the magnetic capture probes and Ru(bpy)32+ labeled amino modified another complementary nucleic acid sequence as the signal probes, which combined the advantages of the highly specific dual-probe hybridization and highly sensitive ECL biosensor technology. In the range of 0.1 fM~10 µM, the method made possible rapid and sensitive detection of the ORF1ab gene of the SARS-CoV-2 within 30 min, and the limit of detection (LOD) was 0.1 fM. The method can also meet the analytical requirements for simulated samples such as saliva and urine with the definite advantages of a simple operation without nucleic acid amplification, high sensitivity, reasonable reproducibility, and anti-interference solid abilities, expounding a new way for efficient and sensitive detection of SARS-CoV-2.

13 May 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
LSLiu Shuai
Liu Shuai
TZTong Zhaoyang
Tong Zhaoyang
CJChunying Jiang
Chunying Jiang
CGChuan Gao
Chuan Gao
JXJianjie Xu
Jianjie Xu
PZPengjie Zhang
Pengjie Zhang
Abrin is a cytotoxin with strong lethality, which is a serious threat to human health and public safety, and thus, highly sensitive detection methods are urgently needed. The phage display affibody has two major modules, among which, the affibody fragment, with small molecular weight, high affinity and easy preparation, can be used for the specific recognition of the target, and the phage shell, with numerous protein copies, can be used as a carrier for the massive enrichment of signal molecules, and thus is particularly suitable as a sensitive probe for signal amplification in high-sensitivity biosensors. In this study, with antibody-coated magnetic microspheres as capture probes, Ru(bpy)32+ and biotin dual-labeled phage display affibodies as the specific signal probes and AuNPs@Ru(bpy)32+ (Ru(bpy)32+-coated gold nanoparticles) as the signal amplification nanomaterials, a new electrochemiluminescence (ECL) biosensor with a four-level sandwich structure of “magnetic capture probe-abrin-phage display affibody-AuNPs@Ru(bpy)32+” was constructed for abrin detection. In this detection mode, AuNPs@Ru(bpy)32+, a gold nanocomposite prepared rapidly via electrical interaction, contained an extremely high density of signal molecules, and the phage display affibodies with powerful loading capacity were not only labeled with Ru(bpy)32+, but also enriched with AuNPs@Ru(bpy)32+ in large amounts. These designs greatly improved the detection capability of the sensor, ultimately achieving the ultra-sensitive detection of abrin. The limit of detection (LOD) was 4.1 fg/mL (3δ/S), and the quantification range was from 5 fg/mL to 5 pg/mL. The sensor had good reproducibility and specificity and performed well in the test of simulated samples. This study expanded the application of affibodies in the field of biosensing and also deeply explored the signal amplification potential of phage display technology, which is of high value for the construction of simple and efficient sensors with high sensitivity.

27 September 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CJChunying Jiang
Chunying Jiang
XMXihui Mu
Xihui Mu
LSLiu Shuai
Liu Shuai
ZLZhiwei Liu
Zhiwei Liu
BLBing Liu
Bing Liu
TZTong Zhaoyang
Tong Zhaoyang
A new and reliable method has been constructed for detecting severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) open reading frames 1ab (ORF1ab) gene via highly sensitive electrochemiluminescence (ECL) biosensor technology based on highly efficient asymmetric polymerase chain reaction (asymmetric PCR) amplification strategy. This method has used magnetic particles coupled with biotin labeled one complementary nucleic acid sequence of the SARS-CoV-2 ORF1ab gene as the magnetic capture probes, and Ru(bpy) 3 2+ labeled amino modified another complementary nucleic acid sequence as the luminescent probes, and then a detection model of magnetic capture probes–asymmetric PCR amplification nucleic acid products-Ru(bpy) 3 2+ labeled luminescent probes is formed, which combines the advantages of highly efficient asymmetric PCR amplification strategy and highly sensitive ECL biosensor technology, enhancing the method sensitivity of detecting the SARS-CoV-2 ORF1ab gene. The method enables the rapid and sensitive detection of the ORF1ab gene and has a linear range of 1~10 6 copies/μL, a regression equation of Y = 534.942X + 2919.301 (R = 0.9983, N = 7), and a limit of detection (LOD) of 1 copy/μL. In summary, it can meet the analytical requirements for simulated saliva and urine samples and has the benefits of easy operation, reasonable reproducibility, high sensitivity, and anti-interference abilities, which can provide a reference for developing efficient field detection methods for SARS-CoV-2.

8 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
ZLZhiwei Liu
Zhiwei Liu
TZTong Zhaoyang
Tong Zhaoyang
YWYuting Wu
Yuting Wu
BLBing Liu
Bing Liu
SFShasha Feng
Shasha Feng
LSLiu Shuai
Liu Shuai
A quantitative structure–activity relationship (QSAR) model for the structure and affinity of abrin aptamers was established. A higher affinity abrin aptamer based on the established QSAR model was screened by site-directed mutagenesis. The fluorescence quenching effect between magnetic microspheres and fluorescent molecules was studied for the first time. A new method for abrin detection based on the interaction between target molecules and fluorescently labeled aptamers on magnetic microspheres was developed, with the detection limit of 5 ng mL−1. This method can overcome the influence of complex environmental interferents in abrin detection and can meet the analysis requirements for simulated samples such as water, soil, and food.