Hossein Alijani

Mr. Hossein Alijani

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Applied Thermal Engineering
Verified
Journal Article
Closed access
HAHossein Alijani
Hossein Alijani
BCBarbaros Cetin
Barbaros Cetin
YAYiğit Akkuş
Yiğit Akkuş
ZDZafer Dursunkaya
Zafer Dursunkaya

3 January 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
HAHeba Ahmed
Heba Ahmed
HAHossein Alijani
Hossein Alijani
AEAhmed El-Ghazaly
Ahmed El-Ghazaly
JHJoseph Halim
Joseph Halim
BMBilly J. Murdoch
Billy J. Murdoch
Leslie YeoLeslie Yeo
Leslie Yeo
MXenes hold immense potential given their superior electrical properties. The practical adoption of these promising materials is, however, severely constrained by their oxidative susceptibility, leading to significant performance deterioration and lifespan limitations. Attempts to preserve MXenes have been limited, and it has not been possible thus far to reverse the material’s performance. In this work, we show that subjecting oxidized micron or nanometer thickness dry MXene films—even those constructed from nanometer-order solution-dispersed oxidized flakes—to just one minute of 10 MHz nanoscale electromechanical vibration leads to considerable removal of its surface oxide layer, whilst preserving its structure and characteristics. Importantly, electrochemical performance is recovered close to that of their original state: the pseudocapacitance, which decreased by almost 50% due to its oxidation, reverses to approximately 98% of its original value, with good capacitance retention ( ≈ 93%) following 10,000 charge–discharge cycles at 10 A g−1. These promising results allude to the exciting possibility for rejuvenating the material for reuse, therefore offering a more economical and sustainable route that improves its potential for practical translation.

15 March 2018 in Heat Transfer Engineering
Verified
Journal Article
Closed access
HAHossein Alijani
Hossein Alijani
BCBarbaros Cetin
Barbaros Cetin
YAYiğit Akkuş
Yiğit Akkuş
ZDZafer Dursunkaya
Zafer Dursunkaya
The thermal characterization of aluminum flat grooved heat pipes is performed experimentally for different groove dimensions. Three heat pipes with groove widths of 0.2 mm, 0.4 mm, and 1.5 mm are used in the experiments. The effect of the amount of the working fluid is extensively studied for each groove width. The results reveal that, although all three succeed in dissipating the heat input through the phase change of the working fluid by continuous evaporation and condensation, the effectiveness of the heat transfer increases with reduced groove width. Furthermore, it is observed that there exists an optimum operating point, where the temperature difference between the heating and cooling sections is at a minimum, and the magnitude of this temperature difference is a strong function of the groove width. To the best of the authors’ knowledge, the combined effects of groove dimensions and the amount of the working fluid, from fully flooded to dry, is reported for the first time for aluminum flat grooved heat pipes.

8 December 2019 in Fluids
Verified
Journal Article
Open access
PDF file
HAHossein Alijani
Hossein Alijani
AÖArzu Özbey
Arzu Özbey
MKMehrdad Karimzadehkhouei
Mehrdad Karimzadehkhouei
Ali KosarAli Kosar
Ali Kosar
Micromixers are of considerable significance in many microfluidics system applications, from chemical reactions to biological analysis processes. Passive micromixers, which rely solely on their geometry, have the advantages of low cost and a less-complex fabrication process. Dean vortices seen in curved microchannels are one of the useful tools to enhance micromixing. In this study, the effects of curve angle on micromixing were experimentally investigated in three curved serpentine micromixers consisting of ten segments with curve angles of 180 ° , 230 ° and 280 ° , at Dean numbers between 12 and 87. To characterize and compare the performance of the micromixers, fluorescence intensity maps and mixing indices were utilized. Accordingly, the micromixer having segments with 280 ° curve angle had significantly higher mixing index values up to the Dean number 60 and outperformed the other two micromixers. This was due to the severe distortion of flow streamlines by Dean vortices and the occurrence of chaotic advection at lower Dean numbers. Beyond the Dean number of 70, no difference was observed in the performance of the micromixers and the mixing index at their outlets had the asymptotic value of 0.93 ± 0.02. Furthermore, the flow behavior of the micromixers was numerically simulated to provide further insight about the mixing phenomena.

9 August 2018 in Fluids
Verified
Journal Article
Open access
PDF file
AÖArzu Özbey
Arzu Özbey
MKMehrdad Karimzadehkhouei
Mehrdad Karimzadehkhouei
HAHossein Alijani
Hossein Alijani
Ali KosarAli Kosar
Ali Kosar
Inertial Microfluidics offer a high throughput, label-free, easy to design, and cost-effective solutions, and are a promising technique based on hydrodynamic forces (passive techniques) instead of external ones, which can be employed in the lab-on-a-chip and micro-total-analysis-systems for the focusing, manipulation, and separation of microparticles in chemical and biomedical applications. The current study focuses on the focusing behavior of the microparticles in an asymmetric curvilinear microchannel with curvature angle of 280°. For this purpose, the focusing behavior of the microparticles with three different diameters, representing cells with different sizes in the microchannel, was experimentally studied at flow rates from 400 to 2700 µL/min. In this regard, the width and position of the focusing band are carefully recorded for all of the particles in all of the flow rates. Moreover, the distance between the binary combinations of the microparticles is reported for each flow rate, along with the Reynolds number corresponding to the largest distances. Furthermore, the results of this study are compared with those of the microchannel with the same curvature angle but having a symmetric geometry. The microchannel proposed in this study can be used or further modified for cell separation applications.

10 June 2025 in ACS Photonics
Verified
Journal Article
Closed access
AZAnastasiia Zalogina
Anastasiia Zalogina
CLChi Li
Chi Li
IZIvan Zhigulin
Ivan Zhigulin
NCNathan Coste
Nathan Coste
HAHossein Alijani
Hossein Alijani
IAIgor Aharonovich
Igor Aharonovich