Beatriz Cordón Ciordia

Mrs. Beatriz Cordón Ciordia


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
BCBeatriz Cordón Ciordia
Beatriz Cordón Ciordia
EVElisa Vilades
Elisa Vilades
EOElvira Orduna-Hospital
Elvira Orduna-Hospital
MSMaría Satue
María Satue
JPJavier Perez-Velilla
Javier Perez-Velilla
EGElena Garcia-Martin
Elena Garcia-Martin
Purpose: To investigate superficial retinal microvascular plexuses detected by optical coherence tomography angiography (OCT-A) in multiple sclerosis (MS) subjects and compare them with healthy controls. Methods: A total of 92 eyes from 92 patients with relapsing-remitting MS and 149 control eyes were included in this prospective observational study. OCT-A imaging was performed using Triton Swept-Source OCT (Topcon Corporation, Japan). The vessel density (VD) percentage in the superficial retinal plexus and optic disc area (6 x 6 mm grid) was measured and compared between groups. Results: MS patients showed a significant decrease VD in the superior (p = 0.005), nasal (p = 0.029) and inferior (p = 0.040) parafoveal retina compared with healthy subjects. Patients with disease durations of more than 5 years presented lower VD in the superior (p = 0.002), nasal (p = 0.017) and inferior (p = 0.022) parafoveal areas compared with healthy subjects. Patients with past optic neuritis episodes did not show retinal microvasculature alterations, but patients with an EDSS score of less than 3 showed a significant decrease in nasal (p = 0.024) and superior (p = 0.006) perifoveal VD when compared with healthy subjects. Conclusions: MS produces a decrease in retinal vascularization density in the superficial plexus of the parafoveal retina. Alterations in retinal vascularization observed in MS patients are independent of the presence of optic nerve inflammation. OCT-A has the ability to detect subclinical vascular changes and is a potential biomarker for diagnosing the presence and progression of MS.

8 September 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
MLMateo Gende Lozano
Mateo Gende Lozano
VGVictor Mallen Gracia
Victor Mallen Gracia
Joaquim de MouraJoaquim de Moura
Joaquim de Moura
BCBeatriz Cordón Ciordia
Beatriz Cordón Ciordia
EMELENA GARCIA MARTIN
ELENA GARCIA MARTIN
Marcos OrtegaMarcos Ortega
Marcos Ortega
Retinal Optical Coherence Tomography (OCT) allows the non-invasive direct observation of the central nervous system, enabling the measurement and extraction of biomarkers from neural tissue that can be helpful in the assessment of ocular, systemic and Neurological Disorders (ND). Deep learning models can be trained to segment the retinal layers for biomarker extraction. However, the onset of ND can have an impact on the neural tissue, which can lead to the degraded performance of models not exposed to images displaying signs of disease during training. We present a fully automatic approach for the retinal layer segmentation in multiple neurodegenerative disorder scenarios, using an annotated dataset of patients of the most prevalent NDs: Alzheimer's disease, Parkinson's disease, multiple sclerosis and essential tremor, along with healthy control patients. Furthermore, we present a two-part, comprehensive study on the effects of ND on the performance of these models. The results show that images of healthy patients may not be sufficient for the robust training of automated segmentation models intended for the analysis of ND patients, and that using images representative of different NDs can increase the model performance. These results indicate that the presence or absence of patients of ND in datasets should be taken into account when training deep learning models for retinal layer segmentation, and that the proposed approach can provide a valuable tool for the robust and reliable diagnosis in multiple scenarios of ND.

7 August 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MHMonica Hernandez
Monica Hernandez
URUbaldo Ramon-Julvez
Ubaldo Ramon-Julvez
EVElisa Vilades
Elisa Vilades
BCBeatriz Cordón Ciordia
Beatriz Cordón Ciordia
EMElvira Mayordomo
Elvira Mayordomo
EGElena Garcia-Martin
Elena Garcia-Martin
Background: Several studies indicate that the anterior visual pathway provides information about the dynamics of axonal degeneration in Multiple Sclerosis (MS). Current research in the field is focused on the quest for the most discriminative features among patients and controls and the development of machine learning models that yield computer-aided solutions widely usable in clinical practice. However, most studies are conducted with small samples and the models are used as black boxes. Clinicians should not trust machine learning decisions unless they come with comprehensive and easily understandable explanations. Materials and methods: A total of 216 eyes from 111 healthy controls and 100 eyes from 59 patients with relapsing-remitting MS were enrolled. The feature set was obtained from the thickness of the ganglion cell layer (GCL) and the retinal nerve fiber layer (RNFL). Measurements were acquired by the novel Posterior Pole protocol from Spectralis Optical Coherence Tomography (OCT) device. We compared two black-box methods (gradient boosting and random forests) with a glass-box method (explainable boosting machine). Explainability was studied using SHAP for the black-box methods and the scores of the glass-box method. Results: The best-performing models were obtained for the GCL layer. Explainability pointed out to the temporal location of the GCL layer that is usually broken or thinning in MS and the relationship between low thickness values and high probability of MS, which is coherent with clinical knowledge. Conclusions: The insights on how to use explainability shown in this work represent a first important step toward a trustworthy computer-aided solution for the diagnosis of MS with OCT.

16 September 2021 in Current Eye Research
Verified
Journal Article
Closed access
BCBeatriz Cordón Ciordia
Beatriz Cordón Ciordia
EOElvira Orduna-Hospital
Elvira Orduna-Hospital
Elisa ViladésElisa Viladés
Elisa Viladés
EMELENA GARCIA MARTIN
ELENA GARCIA MARTIN
JGJavier García-Campayo
Javier García-Campayo
MSMaría Satué
María Satué
To evaluate the inner retinal layers in fibromyalgia (FM) patients compared to control subjects using posterior pole protocol (PPole) analysis in optical coherence tomography (OCT) and to correlate...

18 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
LSLuis de Santiago
Luis de Santiago
MCM. Ortiz del Castillo
M. Ortiz del Castillo
EMELENA GARCIA MARTIN
ELENA GARCIA MARTIN
MSMARIA JESUS RODRIGO SANJUAN
MARIA JESUS RODRIGO SANJUAN
ESEva María Sánchez-Morla
Eva María Sánchez-Morla
LBLuciano Boquete
Luciano Boquete
As multiple sclerosis (MS) usually affects the visual pathway, visual electrophysiological tests can be used to diagnose it. The objective of this paper is to research methods for processing multifocal electroretinogram (mfERG) recordings to improve the capacity to diagnose MS. MfERG recordings from 15 early-stage MS patients without a history of optic neuritis and from 6 control subjects were examined. A normative database was built from the control subject signals. The mfERG recordings were filtered using empirical mode decomposition (EMD). The correlation with the signals in a normative database was used as the classification feature. Using EMD-based filtering and performance correlation, the mean area under the curve (AUC) value was 0.90. The greatest discriminant capacity was obtained in ring 4 and in the inferior nasal quadrant (AUC values of 0.96 and 0.94, respectively). Our results suggest that the combination of filtering mfERG recordings using EMD and calculating the correlation with a normative database would make mfERG waveform analysis applicable to assessment of multiple sclerosis in early-stage patients.

27 August 2022 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
EMELENA GARCIA MARTIN
ELENA GARCIA MARTIN
ATAlvaro Tello
Alvaro Tello
Elisa ViladésElisa Viladés
Elisa Viladés
JPJavier Perez-Velilla
Javier Perez-Velilla
BCBeatriz Cordón Ciordia
Beatriz Cordón Ciordia
MSMaría Satué
María Satué
Background. To evaluate the neuroretina and retinal vasculature of fibromyalgia (FM) patients and calculate a linear discriminant function (LDF) to improve retinal parameters’ contribution to FM diagnosis. Methods. Fifty FM patients and 232 healthy controls underwent retinal evaluation using swept-source optical coherence tomography (SS-OCT) angiography (Triton plus; Topcon) and spectral domain OCT (SD-OCT) (Spectralis; Heidelberg). The macular (m) and peripapillary (p) retinal nerve fibre layer (RNFL) and ganglion cell layer (GCL) were assessed, as was the macular vascular density. A logistic regression analysis was performed, and an LDF was calculated to evaluate OCT’s contribution to FM diagnosis. Results. With Triton OCT, the patients presented pRNFL thinning in the temporal sector ( ). Spectralis OCT measurements showed decreased pRNFL in patients in the following sectors: superonasal, ; nasal, ; inferonasal, ; temporal, ; and inferotemporal, . No significant differences were observed in the macular vascular plexus between patients and controls. However, vascular density in the superior sector showed a strong inverse correlation with disease duration (r = −0.978, ). The LDF calculated for Spectralis OCT yielded an area under the ROC curve of 0.968. Conclusions. FM patients present RNFL thinning observable using SS- and SD-OCT. However, these patients show similar vascular density in the macular area to healthy controls. The LDF that combines several RNFL parameters obtained using Spectralis OCT gives this device a powerful ability to differentiate between healthy individuals and individuals with FM.