Jan Reichmann

Mr. Jan Reichmann

StatConsult GmbH
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MKMahmut Enes Kayaalp
Mahmut Enes Kayaalp
AAAlison N Agres
Alison N Agres
JRJan Reichmann
Jan Reichmann
MBMaxim Bashkuev
Maxim Bashkuev
GDGeorg Duda
Georg Duda
RBRoland Becker
Roland Becker
Fast-track surgery is becoming increasingly popular, whereas the monitoring of postoperative rehabilitation remains a matter of considerable debate. The aim of this study was to validate a newly developed wearable system intended to monitor knee function and mobility. A sensor system with a nine-degree-of-freedom (DOF) inertial measurement unit (IMU) was developed. Thirteen healthy volunteers performed five 10-meter walking trials with simultaneous sensor and motion capture data collection. The obtained kinematic waveforms were analysed using root mean square error (RMSE) and correlation coefficient (CC) calculations. The Bland–Altman method was used for the agreement of discrete parameters consisting of peak knee angles between systems. To test the reliability, 10 other subjects with sensors walked a track of 10 metres on two consecutive days. The Pearson CC was excellent for the walking data set between both systems (r = 0.96) and very good (r = 0.95) within the sensor system. The RMSE during walking was 5.17° between systems and 6.82° within sensor measurements. No significant differences were detected between the mean values observed, except for the extension angle during the stance phase (E1). Similar results were obtained for the repeatability test. Intra-class correlation coefficients (ICCs) between systems were excellent for the flexion angle during the swing phase (F1); good for the flexion angle during the stance phase (F2) and the re-extension angle, which was calculated by subtracting the extension angle at swing phase (E2) from F2; and moderate for the extension angle during the stance phase (E1), E2 and the range of motion (ROM). ICCs within the sensor measurements were good for the ROM, F2 and re-extension, and moderate for F1, E1 and E2. The study shows that the novel sensor system can record sagittal knee kinematics during walking in healthy subjects comparable to those of a motion capture system.

21 November 2023 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
SKSebastian Kersten
Sebastian Kersten
Robert PrillRobert Prill
Robert Prill
HHHassan Tarek Hakam
Hassan Tarek Hakam
HHHannes Hofmann
Hannes Hofmann
MKMahmut Enes Kayaalp
Mahmut Enes Kayaalp
RBRoland Becker
Roland Becker
Inertial measurement units (IMUs) are increasingly being used to assess knee function. The aim of the study was to record patients’ activity levels and to detect new parameters for knee function in the early postoperative phase after TKA. Twenty patients (n = 20) were prospectively enrolled. Two sensors were attached to the affected leg. The data were recorded from the first day after TKA until discharge. Algorithms were developed for detecting steps, range of motion, horizontal, sitting and standing postures, as well as physical therapy. The mean number of steps increased from day 1 to discharge from 117.4 (SD ± 110.5) to 858.7 (SD ± 320.1), respectively. Patients’ percentage of immobilization during daytime (6 a.m. to 8 p.m.) was 91.2% on day one and still 69.9% on the last day. Patients received daily continuous passive motion therapy (CPM) for a mean of 36.4 min (SD ± 8.2). The mean angular velocity at day 1 was 12.2 degrees per second (SD ± 4.4) and increased to 28.7 (SD ± 16.4) at discharge. This study shows that IMUs monitor patients’ activity postoperatively well, and a wide range of interindividual motion patterns was observed. These sensors may allow the adjustment of physical exercise programs according to the patient’s individual needs.

27 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LMLotanna Mba
Lotanna Mba
Robert PrillRobert Prill
Robert Prill
JLJonathan Lettner
Jonathan Lettner
NRNikolai Ramadanov
Nikolai Ramadanov
RKRobert Krause
Robert Krause
RBRoland Becker
Roland Becker
Determining whether preoperative performance-based knee function predicts postoperative performance-based knee function and whether patient-reported outcome measures (PROMs) completed by participants can detect these changes could significantly enhance the planning of postoperative rehabilitation for patients following total knee arthroplasty (TKA). This study aims to collect data on performance-based knee function using inertial measurement units (IMUs) worn by participants both preoperatively and postoperatively. PROMs will be completed by the patients before and after surgery to assess their ability to detect the same changes in performance-based knee function measured by the sensors. Additionally, the study will investigate the correlation between the degree of knee alignment correction and postoperative performance-based knee function in participants after TKA.