Matteo Dongellini

Dr. Matteo Dongellini


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015 in Applied Thermal Engineering
Verified
Journal Article
Closed access
Matteo DongelliniMatteo Dongellini
Matteo Dongellini
Claudia NaldiClaudia Naldi
Claudia Naldi
Gian Luca MoriniGian Luca Morini
Gian Luca Morini

1 January 2014 in Energy Procedia
Verified
Journal Article
Open access
Matteo DongelliniMatteo Dongellini
Matteo Dongellini
CMCosimo Marinosci
Cosimo Marinosci
Gian Luca MoriniGian Luca Morini
Gian Luca Morini
In order to reduce energy consumptions for sustainable and energy-efficient manufacturing, continuous energy audit and process tracking of industrial machines are essential. Compared to other non-residential buildings that have been widely researched, industrial buildings are generally characterized by larger thermal loads, ventilation losses and pollution control requirements. This paper presents the results of a preliminary energy audit carried out on 8 large industrial buildings of a famous car manufacturing holding in Italy. Energy demand for heating varied from 6 to just over 74 kWh/m3year among the buildings of the site. The energy audit enabled to build a specific factory energy model which has been used in order to analyze the impact of various energy saving actions on the primary energy consumptions of the site. It has been demonstrated that in this specific case the improvement of the building envelopes and the optimization of the performances of the existing HVAC systems can determine a reduction of gas consumption up to 15% per year with a predicted annual economic saving of the order of 100000 €; the total simple pay-back time of the proposed thermal retrofitting is evaluated to be less than 6 year

29 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Eugenia Rossi di SchioEugenia Rossi di Schio
Eugenia Rossi di Schio
VBVincenzo Ballerini
Vincenzo Ballerini
Matteo DongelliniMatteo Dongellini
Matteo Dongellini
Paolo ValdiserriPaolo Valdiserri
Paolo Valdiserri
In this paper, dynamic simulations of the seasonal coefficient of performance (SCOP) of Air-Source Heat Pumps will be presented by considering three different heat pump systems coupled with the same building located in three different Italian municipalities: S. Benedetto del Tronto (42°58′ North, 13°53′ East), Milan (45°28′ North, 9°10′ East), and Livigno (46°28′ North, 10°8′ East). Dynamic simulations were conducted by employing the software package TRNSYS and by considering real weather data (i.e., outdoor air temperature and humidity as well as solar radiation) referring to the three abovementioned cities for a period of 8 years (2013–2020) and collected from on-site weather stations. Attention has been paid to the modeling of the heat pump defrost cycles in order to evaluate their influence on the unit’s seasonal performance. Results show that, when referring to different years, the thermal energy demand displays huge variations (in some cases it can even double its value), while the effective SCOP is characterized by scarce variability. Sensible variations in SCOP values are achieved for Livigno.

17 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Matteo DongelliniMatteo Dongellini
Matteo Dongellini
CNChristian Natale
Christian Natale
Claudia NaldiClaudia Naldi
Claudia Naldi
Eugenia Rossi di SchioEugenia Rossi di Schio
Eugenia Rossi di Schio
Paolo ValdiserriPaolo Valdiserri
Paolo Valdiserri
Gian Luca MoriniGian Luca Morini
Gian Luca Morini
The European Parliament has imposed to reduce by 2030 whole HFC emissions by at least two-thirds with respect to 2014 levels. With the aim of contributing to determine the energy and environmental advantages of refrigerants alternative to R-410A, this paper reports the results of a numerical study focused on an HVAC system coupled to a residential building and based on a reversible electric heat pump. In particular, two heat pump typologies are considered: an air-source and a ground-source heat pump, both operating with the two refrigerants R-410A and R-454B. The environmental performance of the studied system is assessed by means of the TEWI (total equivalent warming impact) index. The adoption of R-454B involves a slight decrease (2–3%) in the overall annual energy performance of the system with respect to the use of R-410A. On the other hand, the working fluid R-454B guarantees a marked decrease in the TEWI indicator. Indeed, considering the current Italian emission factor of electricity taken from the grid, the total emissions over the entire heat pump operating life drop by about 25% and can decrease by up to 89% in perspective, following the current reduction trend of the emission factor.

30 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
Matteo DongelliniMatteo Dongellini
Matteo Dongellini
Paolo ValdiserriPaolo Valdiserri
Paolo Valdiserri
Claudia NaldiClaudia Naldi
Claudia Naldi
Gian Luca MoriniGian Luca Morini
Gian Luca Morini
The influence of emitters, heat pump size and building envelope thermal inertia was investigated on the energy consumption of a heat pump-based heating system with a numerical study performed with the dynamic software TRNSYS. An algorithm based on a Thermal Inertia Control Logic (TICL), which can exploit the capability of the building envelope to store thermal energy, has been applied. When the proposed algorithm is employed, the indoor air temperature set-point is increased when the outdoor temperature is larger than the bivalent temperature of the building-heat pump system. Different configurations of the heating system were simulated considering either convective (fan-coil) or radiant (radiant floor) emitters coupled to a variable-speed air-to-water heat pump. Simulations have been carried out considering a reference building derived from the IEA SHC Task 44 and evaluating the influence of the proposed control logic on both the heat pump seasonal energy performance and the internal comfort conditions perceived by the building users. The obtained results highlight how the introduced TICL can guarantee the use of downsized heat pumps, coupled to radiant emitters, with a significant enhancement of the seasonal performance factor up to 10% and a slight improvement of comfort conditions. On the other hand, when convective terminal units are considered the proposed logic is not effective and the overall energy consumption of the system increases up to 15%.

28 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VBVincenzo Ballerini
Vincenzo Ballerini
Eugenia Rossi di SchioEugenia Rossi di Schio
Eugenia Rossi di Schio
Paolo ValdiserriPaolo Valdiserri
Paolo Valdiserri
Claudia NaldiClaudia Naldi
Claudia Naldi
Matteo DongelliniMatteo Dongellini
Matteo Dongellini
In agreement with the decarbonization of the building sector to meet the 2050 climate neutrality targets, borehole thermal storage for solar energy represents a potential solution to increase the energy efficiency of renewable energy plants. As is well known, electricity is not the optimum solution to integrate large inflows of fluctuating renewable energy. In the present paper, we investigate the possibility to use the solar collector to give energy to the borehole field. In detail, a solar-assisted geothermal heat pump is applied to a school located in Milan, Italy. In winter, both the energy from the solar collector and the heat pump are collected into a storage tank connected to the emission terminals, whereas, in summer, as there is no energy demand, the hot water from the solar collector flows into the geothermal probes. By means of this seasonal thermal energy storage technology, the intermittent solar energy collected and stored during the summer months can be utilized during the winter months when the heating demand is high. A long-term dynamic analysis is performed by employing Trnsys. The results show that solar collectors coupled with ground-source heat pumps can give an important contribution to the soil temperature drift, and this also applies in cases of un-balanced loads during the heating season. Moreover, the employment of solar collectors increases the seasonal coefficient of performance of the heat pumps and may rise to reductions to the probes field.