Satoshi Konishi

Prof. Satoshi Konishi


Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
TKTaizo Kobayashi
Taizo Kobayashi
KSKazunori Shimizu
Kazunori Shimizu
YKYoshihiro Kaizuma
Yoshihiro Kaizuma
SKSatoshi Konishi
Satoshi Konishi
This paper reports a novel combination of hydrophilic/hydrophobic materials for the evolution of liquid manipulation. Droplet generation based on a hydrophilic/hydrophobic mechanism is a promising method for highly accurate liquid manipulations. Although several droplet manipulation devices utilizing hydrophilic/hydrophobic patterns have been reported, it has been difficult to split fluid into droplets solely through hydrophilic/hydrophobic patterns in a microchannel. In this study, a material combination for fabricating hydrophilic/hydrophobic patterns was investigated and their wettability difference was enhanced for droplet generation. To improve hydrophilicity, we attempted to increase the surface area of silicon oxide through pulsed plasma chemical vapor deposition (PPCVD). To improve hydrophobicity, the damage to the hydrophobic patterns in the fabrication process was reduced. We successfully enhanced the difference in contact angles from 54.3° to 86.6° by combining the developed hydrophilic material and hydrophobic material. The developed material combination could successfully split fluid into a quantitative droplet of 14.1 nL in a microfluidic chip. Because the developed hydrophilic/hydrophobic combination enables the formation of a droplet with desirable shape in microchannels, the developed hydrophilic/hydrophobic combination is a promising component for lab-on-a-chip applications.

30 October 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SKSatoshi Konishi
Satoshi Konishi
AHAkiya Hirata
Akiya Hirata
The integration of a flexible temperature sensor with a soft microactuator (a pneumatic balloon actuator) for a functional microfinger is presented herein. A sensor integrated with a microactuator can actively approach a target for contact detection when a distance exists from the target or when the target moves. This paper presents a microfinger with temperature sensing functionality. Moreover, thermocouples, which detect temperature based on the Seebeck effect, are designed for use as flexible temperature sensors. Thermocouples are formed by a pair of dissimilar metals or alloys, such as copper and constantan. Thin-film metals or alloys are patterned and integrated in the microfinger. Two typical thermocouples (K-type and T-type) are designed in this study. A 2.0 mm × 2.0 mm sensing area is designed on the microfinger (3.0 mm × 12 mm × 400 μm). Characterization indicates that the output voltage of the sensor is proportional to temperature, as designed. It is important to guarantee the performance of the sensor against actuation effects. Therefore, in addition to the fundamental characterization of the temperature sensors, the effect of bending deformation on the characteristics of the temperature sensors is examined with a repeated bending test consisting of 1000 cycles.

23 July 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KSKazunori Shimizu
Kazunori Shimizu
SKShigeru Kawakami
Shigeru Kawakami
KHKouji Hayashi
Kouji Hayashi
HKHideyuki Kinoshita
Hideyuki Kinoshita
KKKoichiro Kuwahara
Koichiro Kuwahara
SKSatoshi Konishi
Satoshi Konishi
We have developed an in vivo transfection method for naked plasmid DNA (pDNA) and siRNA in mice by using a tissue suction device. The target tissue was suctioned by a device made of polydimethylsiloxane (PDMS) following the intravenous injection of naked pDNA or siRNA. Transfection of pDNA encoding luciferase was achieved by the suction of the kidney, liver, spleen, and heart, but not the duodenum, skeletal muscle, or stomach. Luciferase expression was specifically observed at the suctioned region of the tissue, and the highest luciferase expression was detected at the surface of the tissue (0.12±0.03 ng/mg protein in mice liver). Luciferase expression levels in the whole liver increased linearly with an increase in the number of times the liver was suctioned. Transfection of siRNA targeting glyceraldehyde 3-phosphate dehydrogenase (GAPDH) gene significantly suppressed the expression of GAPDH mRNA in the liver. Histological analysis shows that severe damage was not observed in the suctioned livers. Since the suction device can be mounted onto the head of the endoscope, this method is a minimally invasive. These results indicate that the in vivo transfection method developed in this study will be a viable approach for biological research and therapies using nucleic acids.

15 February 2016 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
SKSatoshi Konishi
Satoshi Konishi
SSShuhei Shimomura
Shuhei Shimomura
STShuhei Tajima
Shuhei Tajima
YTYasuhiko Tabata
Yasuhiko Tabata
This paper describes a pneumatic balloon actuator (PBA) composed of polydimethylsiloxane (PDMS) for cellular aggregate manipulation. We evaluated the ability of the microdevice to manipulate a tiny and sensitive cellular aggregate without causing serious damage. We used human mesenchymal stem cells (hMSCs) for the cellular aggregate. We describe the design, fabrication, characterization and operation of the soft microfingers to pinch and release a spherical hMSC aggregate (φ200 μm), and we employed a PBA to serve as an artificial muscle to drive the microfingers. A design of the microfingers in terms of dimensions, generated force and contact conditions was accomplished. The designed dimensions of a single finger were 560 μm×900 μm. In summary, we demonstrate the utility of the surface modification of a fingertip for pinching and releasing a cellular aggregate and describe a manipulation system that was constructed to drive and control the microfingers. The implemented manipulation system, which is composed of microfingers and a positioning mechanism, was tested and verified in a series of operations.

11 June 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SKSatoshi Konishi
Satoshi Konishi
COChikara Ohya
Chikara Ohya
TYTatsuhiro Yamada
Tatsuhiro Yamada
Methodological advances in on-chip technology enable high-throughput drug screening, such as droplet-array sandwiching technology. Droplet-array sandwiching technology involves upper and lower substrates with a droplet-array designed for a one-step process. This technology is, however, limited to batch manipulation of the droplet-array. Here, we propose a method for selective control of individual droplets, which allows different conditions for individual droplet pairs. Electrowetting-on-dielectric (EWOD) technology is introduced to control the height of the droplets so that the contact between droplet-pairs can be individually controlled. Circular patterns 4 mm in diameter composed of electrodes for EWOD and hydrophilic–hydrophobic patterns for droplet formation 4 μl in volume were developed. We demonstrate the selective control of the droplet height by EWOD for an applied voltage up to 160 V and selective control of the contact and transport of substances. Presented results will provide useful method for advanced drug screening, including cell-based screening.

9 November 2000 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
PCPierre Cusin
Pierre Cusin
TSTakuhiko Sawai
Takuhiko Sawai
SKSatoshi Konishi
Satoshi Konishi
In this paper, we present a piezoelectric linear micropositioner. Its principle and configuration provide an elegant solution to confined positioning problems requiring compact systems. The developed device shows a high accuracy together with large travel ranges, due to a stepwise operation principle. A simple, low-cost realization process combined with an assembly step has been used to implement the device. The positioner operation principle is based on the well known Inchworm principle: the accurate synchronization of piezoelectric actuation and the use of electrostatic forces as clamping systems produces a step-by-step driving of a slider along the direction of the piezotransducer expansion. The applied principle makes possible a flexible and reliable control of the slider positioning speed, either through the `step-by-step' sequence frequency or through the step length. A positioner was designed and realized to demonstrate the device working principle. Bidirectional, millimeter-range slider motion was performed and slider speeds ranging from a few µm s-1 to a few hundreds of µm s-1 were measured. Three hundred nm steps were estimated at 10 V driving voltage. The process used also allows the realization of similar X-Y positioner designs combining several degrees of freedom.