Marek Wyleżoł

Prof. Marek Wyleżoł

Silesian University of Technology, Institute of Fundamentals of Machinery Design
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Composite Structures
Verified
Journal Article
Closed access
Andrzej KatuninAndrzej Katunin
Andrzej Katunin
AWAngelika Wronkowicz-Katunin
Angelika Wronkowicz-Katunin
WDWojciech Danek
Wojciech Danek
Marek WyleżołMarek Wyleżoł
Marek Wyleżoł

29 November 2019 in Polymers
Verified
Journal Article
Open access
PDF file
Krzysztof FicekKrzysztof Ficek
Krzysztof Ficek
Jolanta RajcaJolanta Rajca
Jolanta Rajca
MSMateusz Stolarz
Mateusz Stolarz
ESEwa Stodolak-Zych
Ewa Stodolak-Zych
JWJaroslaw Wieczorek
Jaroslaw Wieczorek
SBStanislaw Blazewicz
Stanislaw Blazewicz
The exact causes of failure of anterior cruciate ligament (ACL) reconstruction are still unknown. A key to successful ACL reconstruction is the prevention of bone tunnel enlargement (BTE). In this study, a new strategy to improve the outcome of ACL reconstruction was analyzed using a bioresorbable polylactide (PLA) stent as a catalyst for the healing process. The study included 24 sheep with 12 months of age. The animals were randomized to the PLA group (n = 16) and control group (n = 8), subjected to the ACL reconstruction with and without the implantation of the PLA tube, respectively. The sheep were sacrificed 6 or 12 weeks post-procedure, and their knee joints were evaluated by X-ray microcomputed tomography with a 50 μm resolution. While the analysis of tibial and femoral tunnel diameters and volumes demonstrated the presence of BTE in both groups, the enlargement was less evident in the PLA group. Also, the microstructural parameters of the bone adjacent to the tunnels tended to be better in the PLA group. This suggested that the implantation of a bioresorbable PLA tube might facilitate osteointegration of the tendon graft after the ACL reconstruction. The beneficial effects of the stent were likely associated with osteogenic and osteoconductive properties of polylactide.

20 May 2024 in Biomaterials Science
Verified
Journal Article
Closed access
PDF file
STSara Targońska
Sara Targońska
MDMonika Dobrzyńska‐Mizera
Monika Dobrzyńska‐Mizera
Maria Laura Di LorenzoMaria Laura Di Lorenzo
Maria Laura Di Lorenzo
MKMonika Knitter
Monika Knitter
ALAlessandra Longo
Alessandra Longo
Rafal Jakub WigluszRafal Jakub Wiglusz
Rafal Jakub Wiglusz
This paper describes in detail the design, fabrication, clinical trial evaluation and post clinical application analysis of 3D-printed bone implants made from the nHAp@PLDLLA [nanohydroxyapatite; poly( l -lactide- co - d , l -lactide)] biomaterial.

4 September 2023 in Materials
Verified
Journal Article
Open access
PDF file
ECEdyta Edyta Chmal-Fudali
Edyta Edyta Chmal-Fudali
DBDaria Basińska
Daria Basińska
AKAgnieszka Kucharska-Jastrząbek
Agnieszka Kucharska-Jastrząbek
MSMarcin H. Struszczyk
Marcin H. Struszczyk
MMMałgorzata Muzalewska
Małgorzata Muzalewska
KGKarolina Gzyra-Jagieła
Karolina Gzyra-Jagieła
Biodegradable craniofacial and cranial implants are a new aspect in terms of reducing potential complications, especially in the long term after surgery. They are also an important contribution in the field of surgical reconstructions for children, for whom it is important to restore natural bone in a relatively short time, due to the continuous growth of bones. The aim of this study was to verify the impact of the technology on biodegradability and to estimate the risk of inappropriate implant resorption time, which is an important aspect necessary to select prototypes of implants for in vivo testing. Prototypes of implants were made using two technologies: 3D printing using a PLDLA: poly(L-co-D,L lactide) (PLDLA) filament containing hydroxyapatite nanoparticles, and injection using PLDLA. After the radiation sterilization process, they were subjected to in vitro degradation under accelerated conditions. As part of this study, the in vitro degradation of newly developed biodegradable implant technologies was assessed in accordance with the guidelines of European standards. It was found that the implant manufacturing process had a significant impact on the degradation time under simulated conditions in various media. Implants made using the injection technique were characterized by lower susceptibility to degradation media compared to the 3D-printed implant under accelerated conditions.

8 October 2024 in Biomaterials Science
Verified
Journal Article
Closed access
PDF file
MDMonika Dobrzyńska‐Mizera
Monika Dobrzyńska‐Mizera
MKMonika Knitter
Monika Knitter
MKMarta Kamińska
Marta Kamińska
DSDaria Szymanowska
Daria Szymanowska
ASAnna Sobczyk-Guzenda
Anna Sobczyk-Guzenda
MLMaria Laura Di Lorenzo
Maria Laura Di Lorenzo
Herein, a chitosan-based thermosensitive hydrogel (CH) containing hydroxyapatite (HAp), poly(lactic acid) (PLDLLA) or their mixture is proposed as an innovative, biomimetic composition with antimicrobial and bone-forming properties for guided bone regeneration. The modified hydrogels were synthesized and characterized to verify their suitability for the treatment of periodontitis periapicalis chronica. Compared to the unmodified hydrogel, both CH_HAp and CH_PLDLLA revealed improved mechanical properties, as evidenced by rotational rheology. FTIR analysis proved that no chemical interplay existed between the components. All the tested samples displayed no cytotoxicity against osteoblast-like cell culture and confirmed antimicrobial features, both crucial from an application perspective. Radiation sterilization dosage was tailored for the tested samples to maintain sterility for a minimum of 8 weeks of storage and limit crosslinking of the samples. Finally, the hydrogel was used in a clinical trial to treat a patient with chronic inflammation of periapical tissues in teeth 26 and 27. The medical procedure proved the safety, nontoxicity, non-allergenicity, and, most importantly, bone-forming properties of the hydrogel formulation. The kinetics of new bone formation was analyzed in-depth using graphical cross-sections of anatomical structures obtained from pre- and post-operative CBCT scans.

1 December 2018 in Advances in Science and Technology Research Journal
Verified
Journal Article
Open access
Marek WyleżołMarek Wyleżoł
Marek Wyleżoł
Purpose. This article deals with a three hybrid modeling methods of a virtual skull implants, developed by the author. 3D models of cranial implants are nowadays necessary for the creation of real implants using modern manufacturing technologies. Methods. These methods combine simultaneous usage...