Yu-Cheng Hsiao

Prof. Yu-Cheng Hsiao

Taipei Medical University
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2022 in Journal of Colloid and Interface Science
Verified
Journal Article
Closed access
YWYung-Fu Wu
Yung-Fu Wu
YHYu-Cheng Hsiao
Yu-Cheng Hsiao
CLChen-Hao Liao
Chen-Hao Liao
CHChia-Shuo Hsu
Chia-Shuo Hsu
SYSibidou Yougbaré
Sibidou Yougbaré
LLLu-Yin Lin
Lu-Yin Lin

1 December 2022 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
CMChinmaya Mutalik
Chinmaya Mutalik
ILI-Hsin Lin
I-Hsin Lin
DKDyah Ika Krisnawati
Dyah Ika Krisnawati
Siti KhaerunnisaSiti Khaerunnisa
Siti Khaerunnisa
MKMuhamad Khafid
Muhamad Khafid
Tsung-Rong KuoTsung-Rong Kuo
Tsung-Rong Kuo
Across the planet, outbreaks of bacterial illnesses pose major health risks and raise concerns. Photodynamic, photothermal, and metal ion release effects of transition metal-based nanocomposites (TMNs) were recently shown to be highly effective in reducing bacterial resistance and upsurges in outbreaks. Surface plasmonic resonance, photonics, crystal structures, and optical properties of TMNs have been used to regulate metal ion release, produce oxidative stress, and generate heat for bactericidal applications. The superior properties of TMNs provide a chance to investigate and improve their antimicrobial actions, perhaps leading to therapeutic interventions. In this review, we discuss three alternative antibacterial strategies based on TMNs of photodynamic therapy, photothermal therapy, and metal ion release and their mechanistic actions. The scientific community has made significant efforts to address the safety, effectiveness, toxicity, and biocompatibility of these metallic nanostructures; significant achievements and trends have been highlighted in this review. The combination of therapies together has borne significant results to counter antimicrobial resistance (4-log reduction). These three antimicrobial pathways are separated into subcategories based on recent successes, highlighting potential needs and challenges in medical, environmental, and allied industries. Graphical Abstract:

11 March 2022 in Cells
Verified
Journal Article
Open access
PDF file
LPLi-Chern Pan
Li-Chern Pan
Nguyen Le Thanh HangNguyen Le Thanh Hang
Nguyen Le Thanh Hang
MCMamadi MS Colley
Mamadi MS Colley
JCJungshan Chang
Jungshan Chang
YHYu-Cheng Hsiao
Yu-Cheng Hsiao
TYTzu-Sen Yang
Tzu-Sen Yang
Photobiomodulation (PBM) has recently emerged in cellular therapy as a potent alternative in promoting cell proliferation, migration, and differentiation during tissue regeneration. Herein, a single-cell near-infrared (NIR) laser irradiation system (830 nm) and the image-based approaches were proposed for the investigation of the modulatory effects in mitochondrial membrane potential (ΔΨm), reactive oxygen species (ROS), and vesicle transport in single living human adipose mesenchymal stem cells (hADSCs). The irradiated-hADSCs were then stained with 2′,7′-dichlorodihydrofluorescein diacetate (H2DCFDA) and Rhodamine 123 (Rh123) to represent the ΔΨm and ROS production, respectively, with irradiation in the range of 2.5–10 (J/cm2), where time series of bright-field images were obtained to determine the vesicle transport phenomena. Present results showed that a fluence of 5 J/cm2 of PBM significantly enhanced the ΔΨm, ROS, and vesicle transport phenomena compared to the control group (0 J/cm2) after 30 min PBM treatment. These findings demonstrate the efficacy and use of PBM in regulating ΔΨm, ROS, and vesicle transport, which have potential in cell proliferation, migration, and differentiation in cell-based therapy.

23 November 2015 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
YHYu-Cheng Hsiao
Yu-Cheng Hsiao
YSYu-Chien Sung
Yu-Chien Sung
Mon-Juan LeeMon-Juan Lee
Mon-Juan Lee
Wei LeeWei Lee
Wei Lee
Liquid crystal (LC)-based biosensors employ highly sensitive interfaces between the alignment layers and LCs to detect biomolecules and their interactions. Present techniques based on optical texture observation of the homeotropic-to-planar response of nematic LCs are limited by their quantitative reproducibility of results, indicating that both the accuracy and reliability of LC-based detection require further improvements. Here we show that cholesteric LC (CLC) can be used as a novel sensing element in the design of an alternative LC-based biosensing device. The chirality of the vertically anchored (VA) CLC was exploited in the detection of bovine serum albumin (BSA), a protein standard commonly used in protein quantitation. The color appearance and the corresponding transmission spectrum of the cholesteric phase changed with the concentration of BSA, by which a detection limit of 1 fg/ml was observed. The optical response of the VA CLC interface offers a simple and inexpensive platform for highly sensitive and naked-eye color-indicating detection of biomolecules, and, thus, may facilitate the development of point-of-care devices for the detection of disease-related biomarkers.

1 October 2013 in Applied Surface Science
Verified
Journal Article
Closed access
Wen-Cheng ChenWen-Cheng Chen
Wen-Cheng Chen
JKJung-Chang Kung
Jung-Chang Kung
CCCheng-Hwei Chen
Cheng-Hwei Chen
YHYu-Cheng Hsiao
Yu-Cheng Hsiao
Chi-Jen ShihChi-Jen Shih
Chi-Jen Shih
CCChi-Sheng Chien
Chi-Sheng Chien

10 February 2020 in Polymers
Verified
Journal Article
Open access
PDF file
YFYu-Jui Fan
Yu-Jui Fan
FCFu-Lun Chen
Fu-Lun Chen
JLJian-Chiun Liou
Jian-Chiun Liou
YHYu-Wen Huang
Yu-Wen Huang
CCChun-Han Chen
Chun-Han Chen
YHYu-Cheng Hsiao
Yu-Cheng Hsiao
We developed a new format for liquid crystal (LC)-based multi-microfluidic immunoassays, hosted on a polydimethylsiloxane substrate. In this design, the orientations of the LCs were strongly affected by the interface between the four microchannel walls and surrounding LCs. When the alignment layer was coated inside a microchannel, the LCs oriented homeotropically and appeared dark under crossed polarizers. After antigens bound to the immobilized antibodies on the alignment layer were coated onto the channel walls, the light intensity of the LC molecules changed from dark to bright because of disruption of the LCs. By employing pressure-driven flow, binding of the antigen/antibody could be detected by optical signals in a sequential order. The multi-microfluidic LC biosensor was tested by detecting bovine serum albumin (BSA) and an immunocomplex of BSA antigen/antibody pairs, a protein standard commonly used in labs. We show that this multi-microfluidic immunoassay was able to detect BSA and antigen/antibody BSA pairs with a naked-eye detection limitation of −0.01 µg/mL. Based on this new immunoassay design, a simple and robust device for LC-based label-free microfluidic immunodetection was demonstrated.