Ting Feng

Dr. Ting Feng

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2020 in Physical Review Applied
Verified
Journal Article
Open access
PDF file
CTChao Tian
Chao Tian
MPMengliu Pei
Mengliu Pei
KSKang Shen
Kang Shen
SLSongde Liu
Songde Liu
ZHZhiming Hu
Zhiming Hu
TFTing Feng
Ting Feng
High-performance imaging is essential for widespread applications of photoacoustic tomography (PAT) in biomedicine. So far, no comprehensive studies are reported on the impact of system factors on imaging performance, in spite of their importance. Based on a prototype PAT scanner, we study eight factors associated with the acoustic reception process in PAT, namely, detector view angle, element number, center frequency, bandwidth, aperture size, focusing, orientation error, and scan step angle error, and investigated how they impact on the image quality. Simulations and experiments are both presented to support the findings in this study. This work is expected to provide a practical guide for advanced PAT scanner design with enhanced imaging performance.

27 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YZYunhao Zhu
Yunhao Zhu
TFTing Feng
Ting Feng
QIAN CHENGQIAN CHENG
QIAN CHENG
Xueding WangXueding Wang
Xueding Wang
SDSidan Du
Sidan Du
Mithun Kuniyil Ajith SinghMithun Kuniyil Ajith Singh
Mithun Kuniyil Ajith Singh
Photoacoustic imaging, with the capability to provide simultaneous structural, functional, and molecular information, is one of the fastest growing biomedical imaging modalities of recent times. As a hybrid modality, it not only provides greater penetration depth than the purely optical imaging techniques, but also provides optical contrast of molecular components in the living tissue. Conventionally, photoacoustic imaging systems utilize bulky and expensive class IV lasers, which is one of the key factors hindering the clinical translation of this promising modality. Use of LEDs which are portable and affordable offers a unique opportunity to accelerate the clinical translation of photoacoustics. In this paper, we first review the development history of LED as an illumination source in biomedical photoacoustic imaging. Key developments in this area, from point-source measurements to development of high-power LED arrays, are briefly discussed. Finally, we thoroughly review multiple phantom, ex-vivo, animal in-vivo, human in-vivo, and clinical pilot studies and demonstrate the unprecedented preclinical and clinical potential of LED-based photoacoustic imaging.

28 February 2024 in Ultrasonics
Verified
Journal Article
Closed access
YYYinshi Yu
Yinshi Yu
TFTing Feng
Ting Feng
HQHaixia Qiu
Haixia Qiu
YGYing Gu
Ying Gu
QCQian Chen
Qian Chen
Haigang MaHaigang Ma
Haigang Ma

27 November 2020 in Journal of Physics D: Applied Physics
Verified
Journal Article
Open access
KSKang Shen
Kang Shen
SLSongde Liu
Songde Liu
TFTing Feng
Ting Feng
JYJie Yuan
Jie Yuan
BZBenpeng Zhu
Benpeng Zhu
CTChao Tian
Chao Tian
Photoacoustic tomography (PAT) has become a fast-evolving biomedical imaging modality in recent years. In PAT, image reconstruction is a critical step to produce high-quality photoacoustic images from raw photoacoustic signals. To date, algorithms based on back projection are the most widely used image reconstruction techniques due to their simplicity and computational efficiency. However, images reconstructed by back projection contain negative values, especially at the edge of photoacoustic sources, which have no physical meaning and are essentially undesired artifacts. In this work, we study the formation mechanism, fundamental causes and removal strategies of the negativity artifacts in back-projection-based PAT. Our results show that limited detector bandwidth and limited view angle are two fundamental causes of negativity artifacts. When the bandwidth of a detector is limited, back-projection signals will be distorted as a result of the loss of frequency contents and negativity artifacts thus appear. When the view angle of the detector is limited, photoacoustic signals propagating in three-dimensional space will be partially lost, resulting in negativity artifacts. Post-processing strategies, such as envelope detection and forced zeroing can be used to remove the negativity artifacts but may cause problems. Since negativity artifacts are a common image quality degradation factor in PAT, understanding their characteristics may expedite the development of novel artifact-removal techniques and artifact-free image reconstruction algorithms, which are of importance to correct image interpretation and quantitative imaging.

1 January 2020 in BME Frontiers
Verified
Journal Article
Open access
PDF file
TFTing Feng
Ting Feng
YZYunhao Zhu
Yunhao Zhu
RMRichard Morris
Richard Morris
KKKenneth M. Kozloff
Kenneth M. Kozloff
Xueding WangXueding Wang
Xueding Wang
Objective and Impact Statement . To study the feasibility of combined functional photoacoustic (PA) and quantitative ultrasound (US) for diagnosis of osteoporosis in vivo based on the detection of chemical and microarchitecture (BMA) information in calcaneus bone. Introduction . Clinically available X-ray or US technologies for the diagnosis of osteoporosis do not report important parameters such as chemical information and BMA. With unique advantages, including good sensitivity to molecular and metabolic properties, PA bone assessment techniques hold a great potential for clinical translation. Methods . By performing multiwavelength PA measurements, the chemical information in the human calcaneus bone, including mineral, lipid, oxygenated-hemoglobin, and deoxygenated-hemoglobin, were assessed. In parallel, by performing PA spectrum analysis, the BMA as an important bone physical property was quantified. An unpaired t -test and a two-way ANOVA test were conducted to compare the outcomes from the two subject groups. Results . Multiwavelength PA measurement is capable of assessing the relative contents of several chemical components in the trabecular bone in vivo , including both minerals and organic materials such as oxygenated-hemoglobin, deoxygenated-hemoglobin, and lipid, which are relevant to metabolic activities and bone health. In addition, PA measurements of BMA show good correlations ( R 2 up to 0.65) with DEXA. Both the chemical and microarchitectural measurements from PA techniques can differentiate the two subject groups. Conclusion . The results from this initial clinical study suggest that PA techniques, by providing additional chemical and microarchitecture information relevant to bone health, may lead to accurate and early diagnosis, as well as sensitive monitoring of the treatment of osteoporosis.

10 November 2023 in Photoacoustics
Verified
Journal Article
Open access
YGYang Gao
Yang Gao
TFTing Feng
Ting Feng
HQHaixia Qiu
Haixia Qiu
YGYing Gu
Ying Gu
QCQian Chen
Qian Chen
Haigang MaHaigang Ma
Haigang Ma
Photoacoustic dermoscopy (PAD) is an emerging non-invasive imaging technology aids in the diagnosis of dermatological conditions by obtaining optical absorption information of skin tissues. Despite advances in PAD, it remains unclear how to obtain quantitative accuracy of the reconstructed PAD images according to the optical and acoustic properties of multilayered skin, the wavelength and distribution of excitation light, and the detection performance of ultrasound transducers. In this work, a computing method of four-dimensional (4D) spectral-spatial imaging for PAD is developed to enable quantitative analysis and optimization of structural and functional imaging of skin. This method takes the optical and acoustic properties of heterogeneous skin tissues into account, which can be used to correct the optical field of excitation light, detectable ultrasonic field, and provide accurate single-spectrum analysis or multi-spectral imaging solutions of PAD for multilayered skin tissues. A series of experiments were performed, and simulation datasets obtained from the computational model were used to train neural networks to further improve the imaging quality of the PAD system. All the results demonstrated the method could contribute to the development and optimization of clinical PADs by datasets with multiple variable parameters, and provide clinical predictability of photoacoustic (PA) data for human skin.