The primary problem of distribution system protection is single-line-to-ground (SLG) fault, particularly in networks with distributed generators (DGs), where asymmetrical phase sequence components caused by SLG faults may lead to system instability. Currently, the location and suppression methods of SLG faults are based on reliable fault diagnosis. Therefore, considering the imbalance of line parameters, this paper analyzes the fault characteristics of zero-sequence voltage (ZSV), and proposes a threshold-online-calculating-based SLG fault diagnosis method, which includes fault detection, fault occurrence moment capture and fault nature estimation. Firstly, the ZSV is measured in real time by the designed feeder terminal unit (FTU), which is embedded with the proposed SLG fault diagnosis method. Secondly, the ZSV signal is decomposed by the Mallat algorithm, and the fault diagnosis thresholds are calculated through the maximum margin hyperplane, which is used for fault detection and fault nature estimation. Finally, the fault occurrence moment is captured by variational mode decomposition (VMD) and its Teager Energy Operator (TEO). The proposed SLG fault diagnosis method has been tested in simulation and physical experiments in a 10kV system, the effectiveness and feasibility have been validated.
24 July 2023 in IEEE Transactions on Instrumentation and Measurement
The single-line-to-ground (SLG) fault is the most common fault in distribution networks. The output current of Cascaded H-bridges (CHB) can be controlled flexibly to suppress SLG fault current. Therefore, a CHB-based active location method is proposed in this paper, which integrates the functions of SLG fault arc suppression, fault section location, and fault nature judgment. When an SLG fault occurs, CHB devices quickly inject full compensated current into the system neutral to suppress the fault current. Then, CHB devices are regulated to reduce the injected current, the variations of zero-sequence voltage and zero-sequence current are actively constructed. The phase characteristics between zero-sequence voltage variation and zero-sequence current variation can be used as the criteria for fault section location and fault nature judgment. In addition, the measurement device, namely the retrofitted feeder terminal unit (FTU), contains signal acquisition module and signal calculation module is designed which can collect the zero-sequence signal and calculate the phase difference. Finally, the effectiveness of these three functions and the fault-location accuracy of the proposed method have been verified through the simulation and experimental cases.
6 March 2025 in IEEE Transactions on Instrumentation and Measurement
Distribution system structures are intricate and variable, with single-phase ground (SPG) fault occurring frequently. Existing section location methods for SPG faults are often influenced by manually set thresholds, resulting in low accuracy. This paper analyzes the relationship between the zero-sequence voltage and zero-sequence current synthesized from three-phase voltage and current under the condition of no zero-sequence transformer installed on the line, and proposes a SPG fault section threshold-free location method based on Swin-Transformer. Firstly, Fourier transform-based data processing methods correct phase errors caused by current transformers (CT) and eliminate the DC bias in synthesized zero-sequence currents. Secondly, the synthesized zero-sequence current waveform and the derivative of zero-sequence voltage waveform are overlaid on the same image, with the enclosed areas shaded to highlight the relationship between the two electrical quantities. Finally, the Transformer model is used to classify the differentiated images between the SPG fault section and sound section to achieve threshold-free fault location. The proposed method has been tested and validated on an industrial prototype in a 10 kV full-scale test system and deployed in actual distribution network. Experimental results demonstrate the method can accurately locate fault sections even under conditions of noise interference and inaccurate trigger timing.
As an effective carrier of new energy collection, DC power grid has characteristics of low inertia and weak damping, which makes DC fault propagate extremely fast. However, the existing protection and DC circuit breaker (DCCB) technique still could not match its fault propagation speed. Therefore, to solve this problem, a novel of flexible fault current limiter (NFFCL) is presented in this paper. Under normal operation condition, NFFCL is connected to DC line in series without negative influence. When a fault occurs to DC line, NFFCL’s rectifier circuit, according to the protection criterion, provides cascade inductor, which is connected to DC line in series, with a set-slope linear current. In this case, the voltage drop between both ends of inductor can be clamped flexibly, which can even completely isolate the fault area. A controlled voltage source (CCVS) is applied to generate inverse flux to prevent the cascading inductor from magnetic saturation. When the fault disappears, the energy of current-limit inductor can be released and transferred to AC power grid through NFFCL’s converter. Finally, simulation cases are carried out to verify the working principles and practicability of proposed NFFCL.
20 June 2025 in IEEE Transactions on Instrumentation and Measurement
Current single-ended fault location methods for single-phase grounding faults in distribution networks are facing challenges such as difficulty in identifying reflected wavefronts, inaccurate judgment of wavefront reflection positions, and limited noise immunity, which reduce their feasibility for engineering applications. This paper proposes an efficient single-ended traveling wave location scheme aimed at enhancing the accuracy and reliability of fault location. Firstly, the improved Pettitt test is employed to accurately determine the arrival time of the fault wavefront, which avoids errors in judgment of the fault occurrence moment. Subsequently, the Pearson correlation coefficient is utilized to identify the initial wavefront and the wavefronts reflected from the fault point, reducing interference caused by other reflected wavefronts. To accurately calibrate the wavefront arrival time, the Hough transform is introduced to determine the wavefront position. Additionally, the paper discusses optimizing the arrangement of traveling wave location devices in the distribution network to improve location accuracy and reduce costs. Compared to existing methods, the proposed scheme directly analyzes the original waveform, achieving more accurate wavefront identification and better noise immunity. The effectiveness of the method is validated through software simulations and physical experiments, demonstrating that the fault location error can be controlled within 5%, even under arc grounding faults or noise interference.
2 May 2024 in IEEE Transactions on Power Electronics
Most of the phase-to-ground parameters induced between distribution lines and ground are asymmetric, which can result in the generation of unbalanced voltage, shifting the neutral point voltage. For compensated distribution networks, the existence of an arc suppression coil can increase the influence of asymmetric parameters and exacerbate the deviation of neutral point voltage. Maintaining the balance of three-phase voltage is not only a prerequisite for the stable operation of the distribution networks, but also for improving the reliability of single-phase ground fault detection. This paper proposes a novel online split-phase identification of asymmetric parameters between distribution lines and ground for unbalanced voltage compensation based on power electronics. Firstly, an adaptive active current-type compensation method based on power electronics is proposed, it can adapt to compensate for threephase unbalanced voltage with different neutral point grounding styles. Secondly, particle swarm optimization is used to realize the online split-phase identification of the phase-to-ground parameters of the distribution power lines. The identified parameters are used to calculate the reference value of the compensation current and the asymmetry of each phase-toground parameter. Finally, the feasibility and effectiveness of the proposed method are verified by simulation and experiment.