When faults occur in the microgrids, high frequency transients will be superimposed on the system currents and voltages. The magnitude of those transients will attenuate as it encounters the discontinuity points in the network such as busbars, or any other impedance discontinuity points. This phenomenon can also be quantified by wavelet energy, which provides a useful tool to detect faults and locate the faulted feeder in the microgrid. In this paper, a novel protection scheme based on the transient wavelet energy of the superimposed current extracted by the Maximal Overlap Discrete Wavelet Transform (MODWT) algorithm is developed to detect faults and locate the faulted feeder in microgrids. Compared with existing protection schemes, the proposed protection scheme has the advantage of being largely immune to the changes in system fault level, fault types and positions, microgrid operating status and the control strategies deployed on the inverters, while presenting much lower requirement on the sampling frequency (10 kHz) compared with travelling wave-based methods. Unlike the conventional differential protection, the proposed scheme does not require synchronized measurement or high bandwidth communication channels, and thus, it can be considered as an economical and promising solution for microgrids.
After the occurrence of a DC-side feeder faults on HVDC transmission systems, protection and fault detection systems are anticipated to minimize their onerous effects, by initiating fault-clearing actions such as selective tripping of circuit breakers. Following the successful fault clearance, a subsequent action of significant importance, is the meticulous estimation of its location as a means to accelerate the line restoration, reduce down-time, limit recovery and repair costs, and hence elevate the overall availability and reliability of the transmission system. In order to capture DC-side fault transients for protection and fault location applications, measuring equipment is required to be placed on HVDC installations. This paper focuses primarily on reviewing the available technologies from the perspective of enabling protection, fault location and automation applications in HVDC systems. The review constitutes a mapping of protection and fault location functions, against the available voltage and current measuring technologies, ultimately unlocking insights for selecting measuring equipment based on the desirable characteristics of protection and fault location systems. The review also revealed that the frequency characteristics of each sensing scheme, primarily refers to the bandwidth of the primary sensor, whereas the overall bandwidth of the complete measuring scheme may be further restricted by the secondary converter and corresponding data acquisition system and signal processing electronics. It was also identified that the use of RC voltage dividers has prevailed for voltage measurements for HVDC applications, due to their superior advantages. The choice of a suitable device for current measurement, depends mainly on the fault detection method used and the frequency range it operates. In particular, the review revealed that fault detection and protection methods are mainly concentrated in a frequency spectrum ranging from a few kHz to 100 kHz, while fault location methods require measurements with a frequency range from 100 kHz up to 2 MHz.
18 July 2022 in IEEE Transactions on Cloud Computing
This paper presents a novel approach for realizing coordinated control of Distributed Energy Resources (DERs) based on cloud-hosted and edge-hosted digital twins (DTs) of DERs. DERs are playing an increasingly important role in supporting the frequency regulation of power systems with massive integration of renewable resources. However, due to the significant differences in DERs’ capability and characteristics, individual and un-coordinated responses from DERs could lead to a less effective overall response with undesirable traits, e.g. slow response, severe overshoots, etc. Therefore, the coordination of DERs is critical to ensure the desirable aggregated overall response. A major shortcoming of conventional centralized or distributed approaches is their significant reliance on real-time communications. This paper addresses the challenges by the application of DTs that can be hosted in the cloud for the centralized control approach and the edge for the distributed approach to minimize the need for real-time communications, while being able to achieve the overall coordination among DERs. The proposed DT-based coordinated control is validated using a realistic real-time simulation test setup, and the results demonstrate that the DT-based coordinated control can significantly improve the aggregated DERs’ response, thus offering effective support to the grid during contingency events.
The increasing penetration of renewable generation has led to the decrease of power systems’ overall inertia, which introduces significant challenges to frequency stability. In this paper, the potential of using Fast Frequency Response (FFR) to enhance frequency control in power systems with low inertia is investigated in detail. A Generic System Frequency Response (GSFR) model taking into account of the penetration level of Non‐Synchronous Generation (NSG) and FFR has been developed and used to investigate the impact of reduced inertia on frequency control and demonstrate that the amount of reserve power to be scheduled can be significantly reduced with the deployment of FFR. The impact of the different FFR resources' characteristics (e.g. response delay, ramp rate, etc.) on the effectiveness of frequency control is also investigated, based on which the desirable specifications for FFR schemes are summarised. These desirable properties of FFR schemes are taken into account in the design of a wide‐area monitoring and control system termed ‘Enhanced Frequency Control Capability (EFCC)’, which is proposed for the delivery of FFR in the future Great Britain transmission system. The design and operation of the EFCC scheme are presented, along with a case study demonstrating its effectiveness in enhancing the frequency control.
18 September 2020 in IEEE Transactions on Power Delivery
This paper presents a new multi-objective control strategy for inverter-interfaced distributed generation (IIDG) to ensure its safe and continuous operation under unbalanced voltage sags. The proposed control strategy can effectively improve the low voltage ride through (LVRT) capability, reduce active power oscillations, and limit overcurrent simultaneously, which are marked as the most important control objectives of IIDG during unbalanced voltage sags. The advanced voltage support scheme, which utilizes positive sequence component, is firstly proposed to maximize the LVRT capability of IIDG during unbalanced voltage sags. Then, to ensure the safety of IIDG, the active power oscillation suppression and current limitation algorithm are designed individually. Based on the control algorithms of such objectives, the multi-objective control method, including scenario classification and reference current determination, is then presented to achieve such three objectives under various system conditions simultaneously. Finally, case studies and evaluations based on MATLAB/Simulink are carried out to illustrate the effectiveness of the proposed method.