Centrifugal pumps are among the most applicable machines in a wide variety of industrial systems for fluid
pumping and transportation. Therefore their optimization has always been of great importance. Pump
impellers play an important role in these machines as the energy transfer takes place in this part. In the
present study, the impeller of a centrifugal pump is optimized by investigating the effect of adding splitter
blades and modifying their geometry. A centrifugal pump is experimentally tested and numerically simulated
and the characteristic curves are obtained. In the first stage, two different sets of splitter blades with different
lengths are added to the impeller and the effect of splitter blade lengths on the results are explored. The case
with the highest total head and overall efficiency is selected for the optimization process. The main blade and
the splitter blade leading edge position and also the splitter blade distance between two successive blades are
selected for the optimization process in the second stage. Efficiency and total head of the pump are
considered as the optimization objectives. Using Design of Experiment (DoE) technique, the design space is
created and response surface method is utilized to find the optimum geometry. The results show adding
splitters can improve total head by about 10.6% and by modifying the geometry using DoE technique it could
increase further by 4.4% with the negligible effect on the pump overall efficiency
In this study, energy harvesting with micro scale hydrodynamic cavitation-thermoelectric generation coupling is investigated. For this, three micro orifices with different geometrical dimensions are fabricated. The hydraulic diameter of the micro orifices are 66.6 μm, 75.2 μm, and 80 μm, while their length is the same (2000μm). Two different working fluids, namely water and Perfluoropentane droplet-water suspension, are utilized for cavitating flows in the fabricated micro orifices. The flow patterns at different upstream pressures are recorded using the high-speed camera system, and the experimental results are analyzed and compared. Thereafter, energy harvesting perspectives of cavitating flows are considered. The released heat from collapsing bubbles and the subsequent temperature rise on the end wall of the microchannel, which can be used as the source for the power generation, is calculated over time. Finally, a miniature energy harvesting system with cavitation system and thermoelectric generator coupling is presented. The maximum power corresponding to two different thermoelectric generators is estimated for with both working fluids and is compared with the required power to run miniature daily used electronics components.
During the last decade, hydrodynamic cavitation has been implemented in various applications such as energy harvesting and biomedical applications. Facile hydrodynamic cavitation methods are required for fulfilling the requirements in these applications. In this study, a new generation microfluidic device containing eight parallel micro-orifices with a new design was fabricated and tested with the purpose of intensifying the cavitating flows and early cavitation inception. The roughness elements in the micro-orifices facilitated cavitation inception. This study presents a general perspective of occurrence of different cavitating flow patterns in microscale and addresses the ambiguities about the conditions for the formation of a specific flow pattern. Cavitation inception occurred with the appearance of small bubbles emerging from roughness elements at a rather low upstream pressure in the open loop experimental setup. A reduction in the cavitation number resulted in the formation of different flow patterns such as cavitation clouds, twin cavities, sheet cavities, and bubbly flows. Having several flow patterns with different intensities all together within a single microfluidic device is the main advantage of the proposed device over the state of the art microfluidic devices. Generation of flow patterns with various released energy levels makes this proposed device a unique multi-functional platform, which can be implemented to a lab on a chip platform for applications such as nanoparticle synthesis and wound healing.
Hydrodynamic cavitation is considered an effective tool to be used in different applications, such as surface cleaning, ones in the food industry, energy harvesting, water treatment, biomedical applications, and heat transfer enhancement. Thus, both characterization and intensification of cavitation phenomenon are of great importance. This study involves design and optimization of cavitation on chip devices by utilizing wall roughness elements and working fluid alteration. Seven different microfluidic devices were fabricated and tested. In order to harvest more energy from cavitating flows, different roughness elements were used to decrease the inlet pressure (input to the system), at which cavitation inception occurs. The implemented wall roughness elements were engineered structures in the shape of equilateral triangles embedded in the design of the microfluidic devices. The cavitation phenomena were also studied using ethanol as the working fluid, so that the fluid behavior differences in the tested cavitation on chip devices were explained and compared. The employment of the wall roughness elements was an effective approach to optimize the performances of the devices. The experimental results exhibited entirely different flow patterns for ethanol compared to water, which suggests the dominant effect of the surface tension on hydrodynamic cavitation in microfluidic channels.