Chandan Karmakar

Dr. Chandan Karmakar

Deakin University, VIC Australia

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2016 in Journal of Medical Internet Research
Verified
Journal Article
Open access
WLWei Luo
Wei Luo
DPDinh Phung
Dinh Phung
TTTruyen Tran
Truyen Tran
SGSunil Gupta
Sunil Gupta
SRSantu Rana
Santu Rana
MBMichael Berk
Michael Berk
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet

1 December 2016 in The Lancet Psychiatry
Verified
Journal Article
Closed access
BFBrisa S Fernandes
Brisa S Fernandes
JSJohann Steiner
Johann Steiner
MMMarc L Molendijk
Marc L Molendijk
SDSeetal Dodd
Seetal Dodd
PNPatricia Nardin
Patricia Nardin
MBMichael Berk
Michael Berk

1 January 2009 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
Chandan KarmakarChandan Karmakar
Chandan Karmakar
AKAhsan Khandoker
Ahsan Khandoker
JGJayavardhana Gubbi
Jayavardhana Gubbi
MPMarimuthu Palaniswami
Marimuthu Palaniswami
Poincaré plot is one of the important techniques used for visually representing the heart rate variability. It is valuable due to its ability to display nonlinear aspects of the data sequence. However, the problem lies in capturing temporal information of the plot quantitatively. The standard descriptors used in quantifying the Poincaré plot (SD 1, SD 2) measure the gross variability of the time series data. Determination of advanced methods for capturing temporal properties pose a significant challenge. In this paper, we propose a novel descriptor "Complex Correlation Measure (CCM)" to quantify the temporal aspect of the Poincaré plot. In contrast to SD 1 and SD 2, the CCM incorporates point-to-point variation of the signal. First, we have derived expressions for CCM. Then the sensitivity of descriptors has been shown by measuring all descriptors before and after surrogation of the signal. For each case study, lag-1 Poincaré plots were constructed for three groups of subjects (Arrhythmia, Congestive Heart Failure (CHF) and those with Normal Sinus Rhythm (NSR)), and the new measure CCM was computed along with SD 1 and SD 2. ANOVA analysis distribution was used to define the level of significance of mean and variance of SD 1, SD 2 and CCM for different groups of subjects. CCM is defined based on the autocorrelation at different lags of the time series, hence giving an in depth measurement of the correlation structure of the Poincaré plot. A surrogate analysis was performed, and the sensitivity of the proposed descriptor was found to be higher as compared to the standard descriptors. Two case studies were conducted for recognizing arrhythmia and congestive heart failure (CHF) subjects from those with NSR, using the Physionet database and demonstrated the usefulness of the proposed descriptors in biomedical applications. CCM was found to be a more significant (p = 6.28E-18) parameter than SD 1 and SD 2 in discriminating arrhythmia from NSR subjects. In case of assessing CHF subjects also against NSR, CCM was again found to be the most significant (p = 9.07E-14). Hence, CCM can be used as an additional Poincaré plot descriptor to detect pathology.

7 March 2017 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
Mohammod Abdul MotinMohammod Abdul Motin
Mohammod Abdul Motin
Chandan KarmakarChandan Karmakar
Chandan Karmakar
MPMarimuthu Palaniswami
Marimuthu Palaniswami
The photoplethysmographic (PPG) signal measures the local variations of blood volume in tissues, reflecting the peripheral pulse modulated by cardiac activity, respiration and other physiological effects. Therefore, PPG can be used to extract the vital cardiorespiratory signals like heart rate (HR), and respiratory rate (RR) and this will reduce the number of sensors connected to the patient’s body for recording these vital signs. In this paper, we propose an algorithm based on ensemble empirical mode decomposition with principal component analysis (EEMD-PCA) as a novel approach to estimate HR and RR simultaneously from PPG signal. To examine the performance of the proposed algorithm, we used 310 (from 35 subjects) and 672 (from 42 subjects) epochs of simultaneously recorded electrocardiogram (ECG), PPG and respiratory signal extracted from MIMIC (Physionet ATM data bank) and Capnobase database respectively. Results of EEMD-PCA based extraction of HR and RR from PPG signal showed that the median RMS error (1st and 3rd quartiles) obtained in MIMIC data set for RR was 0.89 (0, 1.78) breaths/min, for HR was 0.57 (0.30, 0.71) beats/min and in Capnobase data set it was 2.77 (0.50, 5.9) breaths/min and 0.69 (0.54, 1.10) beats/min for RR and HR respectively. These results illustrated that the proposed EEMD-PCA approach is more accurate in estimating HR and RR than other existing methods. Efficient and reliable extraction of HR and RR from the pulse oximeter’s PPG signal will help patients for monitoring HR and RR with low cost and less discomfort.

1 August 2018 in Journal of Affective Disorders
Verified
Journal Article
Closed access
LBLydia Brown
Lydia Brown
Chandan KarmakarChandan Karmakar
Chandan Karmakar
Richard J. GrayRichard J. Gray
Richard J. Gray
RJRipu Jindal
Ripu Jindal
TLTerrence Lim
Terrence Lim
CBChristina Bryant
Christina Bryant

7 May 2024 in Internet of Things
Verified
Journal Article
Open access
MRMd Saifur Rahman
Md Saifur Rahman
Shantanu PalShantanu Pal
Shantanu Pal
SMShubh Mittal
Shubh Mittal
TCTisha Chawla
Tisha Chawla
Chandan KarmakarChandan Karmakar
Chandan Karmakar