Md Saifur Rahman

Mr. Md Saifur Rahman

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
AAAngela An
Angela An
MRMd Saifur Rahman
Md Saifur Rahman
JZjingwen zhou
jingwen zhou
James Jin KangJames Jin Kang
James Jin Kang
Recently, various sophisticated methods, including machine learning and artificial intelligence, have been employed to examine health-related data. Medical professionals are acquiring enhanced diagnostic and treatment abilities by utilizing machine learning applications in the healthcare domain. Medical data have been used by many researchers to detect diseases and identify patterns. In the current literature, there are very few studies that address machine learning algorithms to improve healthcare data accuracy and efficiency. We examined the effectiveness of machine learning algorithms in improving time series healthcare metrics for heart rate data transmission (accuracy and efficiency). In this paper, we reviewed several machine learning algorithms in healthcare applications. After a comprehensive overview and investigation of supervised and unsupervised machine learning algorithms, we also demonstrated time series tasks based on past values (along with reviewing their feasibility for both small and large datasets).

7 May 2024 in Internet of Things
Verified
Journal Article
Open access
MRMd Saifur Rahman
Md Saifur Rahman
Shantanu PalShantanu Pal
Shantanu Pal
SMShubh Mittal
Shubh Mittal
TCTisha Chawla
Tisha Chawla
Chandan KarmakarChandan Karmakar
Chandan Karmakar

13 April 2022 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
MRMd Saifur Rahman
Md Saifur Rahman
Chandan KarmakarChandan Karmakar
Chandan Karmakar
INIynkaran Natgunanathan
Iynkaran Natgunanathan
JYJohn Yearwood
John Yearwood
MPMarimuthu Palaniswami
Marimuthu Palaniswami
Electrocardiogram (ECG) signal quality indices (SQIs) are essential for improving diagnostic accuracy and reliability of ECG analysis systems. In various practical applications, the ECG signals are corrupted by different types of noise. These corrupted ECG signals often provide insufficient and incorrect information regarding a patient’s health. To solve this problem, signal quality measurements should be made before an ECG signal is used for decision-making. This paper investigates the robustness of existing popular statistical signal quality indices (SSQIs): relative power of QRS complex (SQI p ), skewness (SQI skew ), signal-to-noise ratio (SQI snr ), higher order statistics SQI (SQI hos ) and peakedness of kurtosis (SQI kur ). We analysed the robustness of these SSQIs against different window sizes across diverse datasets. Results showed that the performance of SSQIs considerably fluctuates against varying datasets, whereas the impact of varying window sizes was minimal. This fluctuation occurred due to the use of a static threshold value for classifying noise-free ECG signals from the raw ECG signals. Another drawback of these SSQIs is the bias towards noise-free ECG signals, that limits their usefulness in clinical settings. In summary, the fixed threshold-based SSQIs cannot be used as a robust noise detection system. In order to solve this fixed threshold problem, other techniques can be developed using adaptive thresholds and machine-learning mechanisms.

24 May 2024 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
MRMd Saifur Rahman
Md Saifur Rahman
Shantanu PalShantanu Pal
Shantanu Pal
JYJohn Yearwood
John Yearwood
Chandan KarmakarChandan Karmakar
Chandan Karmakar
Automatic electrocardiogram (ECG) signal analysis for heart disease detection has gained significant attention due to busy lifestyles. However, ECG signals are susceptible to noise, which adversely affects the performance of ECG signal analysers. Traditional blind filtering methods use predefined noise frequency and filter order, but they alter ECG biomarkers. Several Deep Learning-based ECG noise detection and classification methods exist, but no study compares recurrent neural network (RNN) and convolutional neural network (CNN) architectures and their complexity. This paper introduces a knowledge-based ECG filtering system using Deep Learning to classify ECG noise types and compare popular computer vision model architectures in a practical Internet of Medical Things (IoMT) framework. Experimental results demonstrate that the CNN-based ECG noise classifier outperforms the RNN-based model in terms of performance and training time. The study shows that AlexNet, visual geometry group (VGG), and residual network (ResNet) achieved over 70% accuracy, specificity, sensitivity, and F1 score across six datasets. VGG and ResNet performances were comparable, but VGG was more complex than ResNet, with only a 4.57% less F1 score. This paper introduces a Deep Learning (DL) based ECG noise classifier for a knowledge-driven ECG filtering system, offering selective filtering to reduce signal distortion. Evaluation of various CNN and RNN-based models reveals VGG and Resnet outperform. Further, the VGG model is superior in terms of performance. But Resnet performs comparably to VGG with less model complexity.

27 February 2024 in IEEE Transactions on Consumer Electronics
Verified
Journal Article
Closed access
MRMd Saifur Rahman
Md Saifur Rahman
Shantanu PalShantanu Pal
Shantanu Pal
JYJohn Yearwood
John Yearwood
Chandan KarmakarChandan Karmakar
Chandan Karmakar
Electrocardiogram (ECG) is the most commonly observed signal for monitoring cardiovascular activities. Recent advances in wearable technology resulted in easy, comfortable and continuous acquisition of ECG signals in non-clinical settings. One of the most important concerns with wearable ECG sensors is noise sensitivity, which affects the precision and dependability of the recorded signals. Recently, deep learning (DL)-based ECG noise detection is widely used to limit the impact of noise in ECG signal and provides better signal quality. However, existing studies did not investigate the deployability of the noise detection and classification model in different devices (e.g., resourceful, semi-resourceful and resource-constraint) and its effect on the performance of the deployed model. This study investigates the impact of model conversions on performances that were done for deploying developed DL-based ECG classifiers in resourceful, semi-resourceful and resource-constraint IoT-enabled devices. That said, we propose a DL-based ECG noise classifier framework to provide noise-free ECG signals on smart devices. Our results show that the VGG model gains accuracy and F1 score 97.31% and 94.18% for resourceful devices, whereas the converted DL-based model for semi-resourceful and resource-constraint devices shows 92.84% and 84.59% respectively. At the same time, the Resnet model improves the 1.34% F1 score from resourceful DL-based models. In addition, Alexnet and VGG model is not fit for resource-constraint devices due to memory limitation. The study provides a guideline for designing DL-based models based on the target IoT deployment environment, which can be followed for problems other than ECG noise classification.

30 August 2023 in Royal Society Open Science
Verified
Journal Article
Open access
RURadhagayathri Udhayakumar
Radhagayathri Udhayakumar
MRMd Saifur Rahman
Md Saifur Rahman
DBDilpreet Buxi
Dilpreet Buxi
VMVaughan G. Macefield
Vaughan G. Macefield
TDTye Dawood
Tye Dawood
Chandan KarmakarChandan Karmakar
Chandan Karmakar
The onset of stress triggers sympathetic arousal (SA), which causes detectable changes to physiological parameters such as heart rate, blood pressure, dilation of the pupils and sweat release. The objective quantification of SA has tremendous potential to prevent and manage psychological disorders. Photoplethysmography (PPG), a non-invasive method to measure skin blood flow changes, has been used to estimate SA indirectly. However, the impact of various wavelengths of the PPG signal has not been investigated for estimating SA. In this study, we explore the feasibility of using various statistical and nonlinear features derived from peak-to-peak (AC) values of PPG signals of different wavelengths (green, blue, infrared and red) to estimate stress-induced changes in SA and compare their performances. The impact of two physical stressors: and Hand Grip are studied on 32 healthy individuals. Linear (Mean, s.d.) and nonlinear (Katz, Petrosian, Higuchi, SampEn, TotalSampEn) features are extracted from the PPG signal’s AC amplitudes to identify the onset, continuation and recovery phases of those stressors. The results show that the nonlinear features are the most promising in detecting stress-induced sympathetic activity. TotalSampEn feature was capable of detecting stress-induced changes in SA for all wavelengths, whereas other features (Petrosian, AvgSampEn) are significant (AUC ≥ 0.8) only for IR and Red wavelengths. The outcomes of this study can be used to make device design decisions as well as develop stress detection algorithms.