Ignacio González Prieto

Dr. Ignacio González Prieto

University of Malaga, Málaga, Andalusia, Spain
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2016 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
WMWan Noraishah Wan Abdul Munim
Wan Noraishah Wan Abdul Munim
Mario J. DuranMario J. Duran
Mario J. Duran
HCHang Seng Che
Hang Seng Che
Mario BermúdezMario Bermúdez
Mario Bermúdez
Ignacio González PrietoIgnacio González Prieto
Ignacio González Prieto
NRNasrudin Abd Rahim
Nasrudin Abd Rahim
The fault tolerance of electric drives is highly appreciated at industry for security and economic reasons, and the inherent redundancy of six-phase machines provides the desired fault-tolerant capability with no extra hardware. For this reason some recent research efforts have been focused on the fault-tolerant design, modeling, and control of six-phase machines. Nevertheless, a unified and conclusive analysis of the postfault capability of six-phase machine is still missing. This paper provides a full picture of the postfault derating in generic six-phase machines and a specific analysis of the fault-tolerant capability of the three mainstream six-phase induction machines (asymmetrical, symmetrical, and dual three phase). Experimental results confirm the theoretical post fault current limits and allow concluding, which is the best six-phase machine for each fault scenario and neutral arrangement.

12 June 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Ignacio González PrietoIgnacio González Prieto
Ignacio González Prieto
Mario J. DuranMario J. Duran
Mario J. Duran
Juan Jose AciegoJuan Jose Aciego
Juan Jose Aciego
CMCristina Martin
Cristina Martin
Federico BarreroFederico Barrero
Federico Barrero
The most serious and recent competitor to the standard field oriented control for induction motors (IM) is the finite control set model predictive control (FCS-MPC). Nevertheless, the extension to multiphase drives faces the impossibility to simultaneously regulate the flux/torque and the secondary current components (typically termed x - y in the literature). The application of a single switching state during the whole sampling period inevitably implies the appearance of x - y voltage/currents that increase the system losses and deteriorate the power quality. These circulating currents become intolerably high as per the unit x - y impedance and the switching frequency diminish. Aiming to overcome this limitation, this work suggests the integration of virtual voltage vectors (VVs) into the FCS-MPC structure. The VVs ensure null x - y voltages on average during the sampling period and the MPC approach selects the most suitable VV to fulfill the flux/torque requirements. The experimental results for a six-phase case study compare the standard FCS-MPC with the suggested method, confirming that the VV-based MPC maintains the flux/torque regulation and successfully improves the power quality and efficiency.

1 April 2015 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HGHugo Guzman
Hugo Guzman
Mario J. DuranMario J. Duran
Mario J. Duran
Federico BarreroFederico Barrero
Federico Barrero
LZLuca Zarri
Luca Zarri
BBBlas Bogado
Blas Bogado
MAManuel R. Arahal
Manuel R. Arahal
One of the most attractive features of multiphase machines is the fault-tolerant capability due to the higher number of phases. Different postfault control strategies based on hysteresis, proportional integral (PI)-resonant, and predictive techniques have been recently proposed. They all proved their capabilities to withstand fault situations and to preserve the fundamental component of the air-gap field, while achieving minimum losses, maximum torque per ampere, and reducing torque vibrations. Nonetheless, due to their recent introduction, no thorough study has yet appeared comparing the performance of these controllers. In this paper, two open-phase fault-tolerant control schemes are experimentally compared in a real five-phase induction machine. The controllers being compared are based on PI-resonant and predictive control techniques, respectively. The experiments include pre- and postfault situations. Obtained results show that both control methods offer nearly the same performance. When compared, predictive control provides faster control response and superior performance at low-speed operation but is found to be less resilient to fault detection delays and to have higher current ripple. Regarding the controller implementation, it is shown that the transition from prefault to postfault operation involves modeling the nonlinear effects observed when an open-phase fault occurs for the predictive controller and proper retuning of the PI trackers for the PI-resonant controller, to ensure postfault operation.

19 September 2016 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Mario BermúdezMario Bermúdez
Mario Bermúdez
Ignacio González PrietoIgnacio González Prieto
Ignacio González Prieto
Federico BarreroFederico Barrero
Federico Barrero
HGHugo Guzman
Hugo Guzman
MDMario J. Duran
Mario J. Duran
Xavier KestelynXavier Kestelyn
Xavier Kestelyn
Direct torque control (DTC) has been widely used as an alternative to traditional field-oriented control (FOC) methods for three-phase drives. The conventional DTC scheme has been successfully extended to multiphase drives in recent times, using hysteresis regulators to independently track the desired torque and flux in symmetrical five-phase induction machines (IMs). The fault-tolerant capability of multiphase drives is an interesting intrinsic advantage for safety-critical applications, where recent research has demonstrated the effectiveness of FOC schemes to perform ripple-free postfault operation. In spite of the utility of DTC methods in normal operation of the multiphase machine, no extension to manage the postfault operation of the drive is found in the literature. In this paper, a novel fault-tolerant DTC scheme is presented. The performance of the proposed method is experimentally validated in a five-phase IM drive considering an open-phase fault condition. Provided tests analyze steady and transient states, including the transition from pre- to postfault operation. Obtained results prove the interest of the proposal, which ensures the open-phase fault-tolerant capability of DTC-controlled five-phase IM drives.

17 February 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Mario J. DuranMario J. Duran
Mario J. Duran
Ignacio González PrietoIgnacio González Prieto
Ignacio González Prieto
NRNatalia Rios-Garcia
Natalia Rios-Garcia
FBFederico Barrero
Federico Barrero
Fault tolerance is much appreciated at industry in applications with high-reliability requirements. Due to their inherent fault-tolerant capability against open-phase faults (OPFs), drives with multiple three-phase windings are ideal candidates in such applications and for this reason many efforts have been devoted to the development of different fault-tolerant control strategies. Fault detection is, however, a previous and mandatory stage in the creation of fault-tolerant drives, and the study of specific OPF detection methods for six-phase drives is still scarce. Taking advantage of the secondary currents (so called x-y currents) that are unique in multiphase machines, this study proposes new fault indices that detect and locate the OPFs without additional hardware. The method proves to be simple and independent of the operating point, control technique, and drive parameters. Comparative experimental results confirm the capability of the proposed method to achieve fast detection times with good robustness.

31 August 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Ignacio González PrietoIgnacio González Prieto
Ignacio González Prieto
Mario J. DuranMario J. Duran
Mario J. Duran
NRNatalia Rios-Garcia
Natalia Rios-Garcia
Federico BarreroFederico Barrero
Federico Barrero
CMCristina Martin
Cristina Martin
Achieving a self-reconfigurable fault-tolerant control in multiphase machines requires a fast fault detection and localization. Most fault detection techniques inherit the three-phase approach by defining fault indices in a per-phase basis. A recent approach suggests an alternative fault detection mechanism based on vector space decomposition (VSD) variables, but the study is limited to open-phase faults (OPFs) for a six-phase drive that is regulated under field-oriented control. It is known, however, that 1) the open-switch faults (OSFs) in the converter are more likely than the OPF in the machine and 2) the drive performance in the event of an open-circuit fault is more critical when model predictive control (MPC) is used. This work extends the study of the VSD fault detection method to multiphase machines with different number of phases (five), control strategy (MPC), and type of faults (OPF and OSF). Although experimental results show that MPC misbehaves after the fault occurrence, the fast detection provided by the VSD approach allows a satisfactory transition to postfault mode of operation.