Ana López Lilao

Dr. Ana López Lilao


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in Science of The Total Environment
Verified
Journal Article
Open access
CRCarla Ribalta
Carla Ribalta
ALAna López Lilao
Ana López Lilao
SES. Estupiñá
S. Estupiñá
AFAna Sofia Fonseca
Ana Sofia Fonseca
Aurelio TobiasAurelio Tobias
Aurelio Tobias
Mar VianaMar Viana
Mar Viana
Packing of raw materials in work environments is a known source of potential health impacts (respiratory, cardiovascular) due to exposure to airborne particles. This activity was selected to test different exposure and risk assessment tools, aiming to understand the effectiveness of source enclosure as a strategy to mitigate particle release. Worker exposure to particle mass and number concentrations was monitored during packing of 7 ceramic materials in 3 packing lines in different settings, with low (L), medium (M) and high (H) degrees of source enclosure. Results showed that packing lines L and M significantly increased exposure concentrations (119-609 μg m-3 respirable, 1150-4705 μg m-3 inhalable, 24,755-51,645 cm-3 particle number), while non-significant increases were detected in line H. These results evidence the effectiveness of source enclosure as a mitigation strategy, in the case of packing of ceramic materials. Total deposited particle surface area during packing ranged between 5.4 and 11.8 × 105 μm2 min-1, with particles depositing mainly in the alveoli (51-64%) followed by head airways (27-41%) and trachea bronchi (7-10%). The comparison between the results from different risk assessment tools (Stoffenmanager, ART, NanoSafer) and the actual measured exposure concentrations evidenced that all of the tools overestimated exposure concentrations, by factors of 1.5-8. Further research is necessary to bridge the current gap between measured and modelled health risk assessments.

1 August 2017 in Applied Clay Science
Verified
Journal Article
Closed access
ALAna López Lilao
Ana López Lilao
MGM.P. Gómez-Tena
M.P. Gómez-Tena
GMG. Mallol
G. Mallol
EME. Monfort
E. Monfort

CRCarla Ribalta
Carla Ribalta
AKAntti Koivisto
Antti Koivisto
ASApostolos Salmatonidis
Apostolos Salmatonidis
ALAna López Lilao
Ana López Lilao
EMEliseo Monfort
Eliseo Monfort
Mar VianaMar Viana
Mar Viana
Mass balance models have proved to be effective tools for exposure prediction in occupational settings. However, they are still not extensively tested in real-world scenarios, or for particle number concentrations. An industrial scenario characterized by high emissions of unintentionally-generated nanoparticles (NP) was selected to assess the performance of a one-box model. Worker exposure to NPs due to thermal spraying was monitored, and two methods were used to calculate emission rates: the convolution theorem, and the cyclic steady state equation. Monitored concentrations ranged between 4.2 × 104–2.5 × 105 cm−3. Estimated emission rates were comparable with both methods: 1.4 × 1011–1.2 × 1013 min−1 (convolution) and 1.3 × 1012–1.4 × 1013 min−1 (cyclic steady state). Modeled concentrations were 1.4-6 × 104 cm−3 (convolution) and 1.7–7.1 × 104 cm−3 (cyclic steady state). Results indicated a clear underestimation of measured particle concentrations, with ratios modeled/measured between 0.2–0.7. While both model parametrizations provided similar results on average, using convolution emission rates improved performance on a case-by-case basis. Thus, using cyclic steady state emission rates would be advisable for preliminary risk assessment, while for more precise results, the convolution theorem would be a better option. Results show that one-box models may be useful tools for preliminary risk assessment in occupational settings when room air is well mixed.

1 August 2017 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
ALAna López Lilao
Ana López Lilao
VFVicenta Sanfélix Forner
Vicenta Sanfélix Forner
GGGustavo Mallol Gasch
Gustavo Mallol Gasch
EGEliseo Monfort Gimeno
Eliseo Monfort Gimeno
A wide variety of raw materials, involving more than 20 samples of quartzes, feldspars, nephelines, carbonates, dolomites, sands, zircons, and alumina, were selected and characterised. Dustiness, i.e., a materials' tendency to generate dust on handling, was determined using the continuous drop method. These raw materials were selected to encompass a wide range of particle sizes (1.6–294 µm) and true densities (2650–4680 kg/m3). The dustiness of the raw materials, i.e., their tendency to generate dust on handling, was determined using the continuous drop method. The influence of some key material parameters (particle size distribution, flowability, and specific surface area) on dustiness was assessed. In this regard, dustiness was found to be significantly affected by particle size distribution. Data analysis enabled development of a model for predicting the dustiness of the studied materials, assuming that dustiness depended on the particle fraction susceptible to emission and on the bulk material's susceptibility to release these particles. On the one hand, the developed model allows the dustiness mechanisms to be better understood. In this regard, it may be noted that relative emission increased with mean particle size. However, this did not necessarily imply that dustiness did, because dustiness also depended on the fraction of particles susceptible to be emitted. On the other hand, the developed model enables dustiness to be estimated using just the particle size distribution data. The quality of the fits was quite good and the fact that only particle size distribution data are needed facilitates industrial application, since these data are usually known by raw materials managers, thus making additional tests unnecessary. This model may therefore be deemed a key tool in drawing up efficient preventive and/or corrective measures to reduce dust emissions during bulk powder processing, both inside and outside industrial facilities. It is recommended, however, to use the developed model only if particle size, true density, moisture content, and shape lie within the studied ranges.

25 March 2015 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
ALAna López Lilao
Ana López Lilao
MBMarine Bruzi
Marine Bruzi
VSVicenta Sanfélix
Vicenta Sanfélix
AGAna Gozalbo
Ana Gozalbo
GMGustavo Mallol
Gustavo Mallol
EMEliseo Monfort
Eliseo Monfort
Several samples of kaolin with different mean particle size were prepared and tested using the continuous drop method, one of the reference test methods according to standard EN 15051:2006 “Workplace atmospheres – Measurement of the dustiness of bulk materials – Requirements and reference test methods.” On the other hand, with a view to relating the dustiness of the materials to their properties, particle size distribution, specific surface area, and Hausner ratio of these samples were determined. This article presents a characterization of these samples and an assessment of the influence of some material parameters on dustiness. The results show that dustiness may significantly be affected by mean particle size, specific surface area, and Hausner ratio. Moreover, it is highlighted that a detailed study of the influence of fine particles content on the dustiness was carried out. This information is deemed essential for establishing the most efficient preventive and/or corrective measures to reduce the generation of fugitive emissions of particulate matter during kaolin processing, both into the outside atmosphere (air pollution) and inside the facilities (occupational health).

8 September 2016 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
ALAna López Lilao
Ana López Lilao
AEA. Escrig
A. Escrig
MOM. J. Orts
M. J. Orts
GMGustavo Mallol
Gustavo Mallol
EMEliseo Monfort
Eliseo Monfort
The classification of Respirable Crystalline Silica (RCS) as carcinogenic for humans has drawn greater attention to crystalline silica exposure in the workplace in recent years, leading to recommendations by safety and health bodies in Europe and the U.S. for lower occupational exposure limits. In view of this new scenario, the present study examined quartz dustiness, as quartz handling is a major source of crystalline silica in the workplace. The study was conducted on test samples with different mean particle sizes, prepared from several commercial quartzes. The quartz particle samples were characterised and the influence of certain quartz particle parameters on quartz dustiness was determined. The results indicate that quartz dustiness may be significantly affected by mean particle size, specific surface area, the Hausner ratio, and fine particle content. The study shows that, in order to minimise the adverse health effects associated with the inhalation of crystalline silica, quartz dustiness may be deemed a key factor in controlling the generation of fugitive quartz emissions during quartz processing, both into the outside atmosphere (air pollution) and inside the facilities (occupational health).