Maja Jovanović

Ms. Maja Jovanović

Vinca Institute of nuclear sciences, Department of Physical Chemistry, PO Box 522 11000 Belgrade
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Atmospheric Environment
Verified
Journal Article
Closed access
DTDušan Branislav Topalović
Dušan Branislav Topalović
Miloš DavidovićMiloš Davidović
Miloš Davidović
MJMaja Jovanović
Maja Jovanović
ABAlena Bartonova
Alena Bartonova
ZRZoran Ristovski
Zoran Ristovski
MJMilena Jovašević-Stojanović
Milena Jovašević-Stojanović

MJMaja Jovanović
Maja Jovanović
JSJasmina Savic
Jasmina Savic
FSFarhad Salimi
Farhad Salimi
Stevanovic SvetlanaStevanovic Svetlana
Stevanovic Svetlana
RBReece Brown
Reece Brown
ZRZoran Ristovski
Zoran Ristovski
To estimate the oxidative potential (OP) of particulate matter (PM), two commonly used cell-free, molecular probes were applied: dithiothreitol (DTT) and dichloro-dihydro-fluorescein diacetate (DCFH-DA), and their performance was compared with 9,10-bis (phenylethynyl) anthracene-nitroxide (BPEAnit). To the best of our knowledge, this is the first study in which the performance of the DTT and DCFH has been compared with the BPEAnit probe. The average concentrations of PM, organic carbon (OC) and elemental carbon (EC) for fine (PM2.5) and coarse (PM10) particles were determined. The results were 44.8 ± 13.7, 9.8 ± 5.1 and 9.3 ± 4.8 µg·m−3 for PM2.5 and 75.5 ± 25.1, 16.3 ± 8.7 and 11.8 ± 5.3 µg·m−3 for PM10, respectively, for PM, OC and EC. The water-soluble organic carbon (WSOC) fraction accounted for 42 ± 14% and 28 ± 9% of organic carbon in PM2.5 and PM10, respectively. The average volume normalized OP values for the three assays depended on both the sampling periods and the PM fractions. The OPBPEAnit had its peak at 2 p.m.; in the afternoon, it was three times higher compared to the morning and late afternoon values. The DCFH and BPEAnit results were correlated (r = 0.64), while there was no good agreement between the BPEAnit and the DTT (r = 0.14). The total organic content of PM does not necessarily represent oxidative capacity and it shows varying correlation with the OP. With respect to the two PM fractions studied, the OP was mostly associated with smaller particles.

13 January 2025 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
PDPamela A. Dominutti
Pamela A. Dominutti
JJJean-Luc Jaffrezo
Jean-Luc Jaffrezo
AMAnouk Marsal
Anouk Marsal
TMTakoua Mhadhbi
Takoua Mhadhbi
RERhabira Elazzouzi
Rhabira Elazzouzi
Gaelle UzuGaelle Uzu
Gaelle Uzu
This paper presents the findings from a collaborative interlaboratory comparison exercise designed to assess oxidative potential (OP) measurements conducted by 20 laboratories worldwide. This study represents an innovative effort as the first exercise specifically aimed at harmonising this type of OP assay, setting a new benchmark in the field. Over the last decade, there has been a noticeable increase in OP studies, with numerous research groups investigating the effects of exposure to air pollution particles through the evaluation of OP levels. However, the absence of standardised methods for OP measurements has resulted in variability in results across different groups, rendering meaningful comparisons challenging. To address this issue, this study engages in an international effort to compare OP measurements using a simplified method (with a dithiothreitol (DTT) assay). Here, we quantify the OP in liquid samples to focus on the protocol measurement itself, while future international OP interlaboratory comparisons (ILCs) should aim to assess the whole chain process, including the sample extraction. We analyse the similarities and discrepancies observed in the results, identifying the critical parameters (such as the instrument used, the use of a simplified protocol, the delivery and analysis time) that could influence OP measurements and provide recommendations for future studies and interlaboratory comparisons even if other crucial aspects, such as sampling PM methods, sample storage, extraction methods and conditions, and the evaluation of other OP assays, still need to be standardised. This collaborative approach enhances the robustness of the OP DTT assay and paves the way for future studies to build on a unified framework. This pioneering work concludes that interlaboratory comparisons provide essential insights into the OP metric and are crucial to move toward the harmonisation of OP measurements.

28 January 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Miloš DavidovićMiloš Davidović
Miloš Davidović
SDSonja Dmitrašinović
Sonja Dmitrašinović
MJMaja Jovanović
Maja Jovanović
JRJelena Radonić
Jelena Radonić
MJMilena Jovašević-Stojanović
Milena Jovašević-Stojanović
Changes in air pollution in the region of the city of Novi Sad due to the COVID-19 induced state of emergency were evaluated while using data from permanently operating air quality monitoring stations belonging to the national, regional, and local networks, as well as ad hoc deployed low-cost particulate matter (PM) sensors. The low-cost sensors were collocated with reference gravimetric pumps. The starting idea for this research was to determine if and to what extent a massive change of anthropogenic activities introduced by lockdown could be observed in main air pollutants levels. An analysis of the data showed that fine and coarse particulate matter, as well as SO2 levels, did not change noticeably, compared to the pre-lockdown period. Isolated larger peaks in PM pollution were traced back to the Aralkum Desert episode. The reduced movement of vehicles and reduced industrial and construction activities during the lockdown in Novi Sad led to a reduction and a more uniform profile of the PM2.5 levels during the period between morning and afternoon air pollution peak, approximately during typical working hours. Daily profiles of NO2, NO, and NOX during the state of emergency proved lower levels during most hours of the day, due to restrictions on vehicular movement. CO during the state of the emergency mainly exhibited a lower level during night. Pollutants having transportation-dominated source profiles exhibited a decrease in level, while pollutants with domestic heating source profiles mostly exhibited a constant level. Considering local sources in Novi Sad, slight to moderate air quality improvement was observed after the lockdown as compared with days before. Furthermore, PM low-cost sensors’ usefulness in air quality assessment was confirmed, as they increase spatial resolution, but it is necessary to calibrate them at the deployment location.

1 January 2023 in Thermal Science
Verified
Journal Article
Open access
PDF file
Stevanovic SvetlanaStevanovic Svetlana
Stevanovic Svetlana
MJMaja Jovanović
Maja Jovanović
MJMilena Jovašević-Stojanović
Milena Jovašević-Stojanović
ZRZoran Ristovski
Zoran Ristovski
In numerous epidemiological studies, exposure to particulate matter (PM) has been associated with negative health outcomes. It has been established so far that the detrimental health effects of particles cannot be explained by a single parameter, such as particle mass, as the complexity of chemical composition and reactivity of particles are not always represented by the mass loadings. The oxidative potential (OP) of aerosol particles represents a promising indicator of their potential toxicity. To develop strategies and regulations at improving the air quality, an increasing number of studies are focused on the application of source apportionment (SA) of PM., while a limited number of SA investigations have been applied to OP. In this review previous research of SA of atmospheric PM OP and proposed guidelines for future studies are summarized. Most of the research studies were carried out in an urban area and focused on PM2.5, while few studies examined other PM fractions. It was noted that the three dominant contributors to OP were biomass burning (9-97%), secondary aerosols (6-67%), and traffic/vehicles (16-88%). The presence of other factors that contributed to the in-crease of OP to a lesser extent depended on the location and season. Further, a considerable discrepancy in the contribution of various OP vs. PM sources was discovered using SA models. Because of this, the use of SA is not equivalent when considering the mass of PM and its toxicity.

21 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
DSDanka B. Stojanović
Danka B. Stojanović
DKDuška Kleut
Duška Kleut
Miloš DavidovićMiloš Davidović
Miloš Davidović
MŽMarija Živković
Marija Živković
URUzahir Ramadan Ramadani
Uzahir Ramadan Ramadani
MJMilena Jovašević-Stojanović
Milena Jovašević-Stojanović
Conventional air quality monitoring networks typically tend to be sparse over areas of interest. Because of the high cost of establishing such monitoring systems, some areas are often completely left out of regulatory monitoring networks. Recently, a new paradigm in monitoring has emerged that utilizes low-cost air pollution sensors, thus making it possible to reduce the knowledge gap in air pollution levels for areas not covered by regulatory monitoring networks and increase the spatial resolution of monitoring in others. The benefits of such networks for the community are almost self-evident since information about the level of air pollution can be transmitted in real time and the data can be analysed immediately over the wider area. However, the accuracy and reliability of newly produced data must also be taken into account in order to be able to correctly interpret the results. In this study, we analyse particulate matter pollution data from a large network of low-cost particulate matter monitors that was deployed and placed in outdoor spaces in schools in central and western Serbia under the Schools for Better Air Quality UNICEF pilot initiative in the period from April 2022 to June 2023. The network consisted of 129 devices in 15 municipalities, with 11 of the municipalities having such extensive real-time measurements of particulate matter concentration for the first time. The analysis showed that the maximum concentrations of PM2.5 and PM10 were in the winter months (heating season), while during the summer months (non-heating season), the concentrations were several times lower. Also, in some municipalities, the maximum values and number of daily exceedances of PM10 (50 μg/m3) were much higher than in the others because of diversity and differences in the low-cost sensor sampling sites. The particulate matter mass daily concentrations obtained by low-cost sensors were analysed and also classified according to the European AQI (air quality index) applied to low-cost sensor data. This study confirmed that the large network of low-cost air pollution sensors can be useful in providing real-time information and warnings about higher pollution days and episodes, particularly in situations where there is a lack of local or national regulatory monitoring stations in the area.