Yuling Li

Yuling Li


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
ZZZeyu Zhao
Zeyu Zhao
JYJia Yan
Jia Yan
TWTao Wang
Tao Wang
YMYanxue Ma
Yanxue Ma
MXMaobin Xie
Maobin Xie
GLGang Li
Gang Li

18 February 2013 in The Journal of the Textile Institute
Verified
Journal Article
Closed access
GLGang Li
Gang Li
YLYanping Liu
Yanping Liu
PLPing Lan
Ping Lan
YLYi Li
Yi Li
YLYuling Li
Yuling Li
Bifurcated biomedical stents (BBSs) produced by three-dimensional tubular technology are typical substitutes for damaged tubular organs such as abdominal aorta branches, trachea branches, and esophagus branches in patients. They are generally made from thin cloth with stent-sutured method, by using manual loom or knitting loom. The existing BBSs may have some problems in busting strength, resistance to fatigue, porosity, and thickness. This paper proposes a novel method of performing design and fabrication for seamless woven BBSs with a modified rigid rapier-shuttle loom automatically. Seamless woven BBSs made from biocompatible polyester filaments were smoothly fabricated through the proposed method. The mechanical properties and water permeability of the resultant BBSs were analyzed by comparing commercial stents VP1200 K according to ISO 7198:1998. The result shows that the new BBS has better performance in terms of surface uniformity, mechanical properties, and water permeability.

6 November 2020 in Autex Research Journal
Verified
Journal Article
Open access
PDF file
YTYuhao Tan
Yuhao Tan
YLYuling Li
Yuling Li
YMYanxue Ma
Yanxue Ma
BRBingjun Rao
Bingjun Rao
Polymethyl methacrylate (PMMA) was used as the dispersed phase and mold silicone was used as the continuous phase to prepare the shear thickening gel (STG) doped with a certain amount of flocks by rotary stirring. STG doped with flocks by a rotary rheometer was tested and observed through a scanning electron microscope. Results revealed that both the rotary stirring sample preparation and the rheological test method of the rotary rheometer could lead to the regular arrangement of flocks and could not reflect shear thickening performance accurately. The flocks showed a random arrangement in STG after the mixing process, and the dynamic mechanical properties were able to be measured with a dynamic mechanical analyzer (DMA). Flocks with a fineness of 3 Denier, 1 mm in length, and a mass ratio of 5% had significant effects on the dynamic mechanical properties of STG. Due to long continuous shearing time, flocks were arranged regularly when the sweeping frequency was higher than 125 Hz, then the shear thickening performance of the doped STG was declined.

Verified
Journal Article
Open access
PDF file
CXChen Xu
Chen Xu
YMYanxue Ma
Yanxue Ma
HHHaihua Huang
Haihua Huang
ZRZheng Ruan
Zheng Ruan
YLYuling Li
Yuling Li
The repair and reconstruction of tracheal defects is a challenging clinical problem. Due to the wide choice of materials and structures, weaving technology has shown unique advantages in simulating the multilayer structure of the trachea and providing reliable performance. Currently, most woven stent-based stents focus only on the effect of materials on stent performance while ignoring the direct effect of woven process parameters on stent performance, and the advantages of weaving technology in tissue regeneration have not been fully exploited. Therefore, this review will introduce the effects of stent materials and fabric construction on the performance of tracheal stents, focusing on the effects of weaving process parameters on stent performance. We will summarize the problems faced by woven stents and possible directions of development in the hope of broadening the technical field of artificial trachea preparation.

26 December 2018 in The Journal of the Textile Institute
Verified
Journal Article
Closed access
FMFenye Meng
Fenye Meng
YLYuling Li
Yuling Li
YMYanxue Ma
Yanxue Ma
XCXiaoying Chen
Xiaoying Chen
The tapered circular tubular (TCT) woven fabric has been applied successfully as the components in vascular prostheses. The application of tapered tubular woven fabric based on the existing weaving technology requires the densification of a large end to ensure porosity uniformity through the tapered tubule. Although the previously proposed equal-cover-factor (ECF) design technique overcame some disadvantages of the conventional densification methods, such as the protruding portions of the dropped yarns as well as the change of both fabric porosity and tensile strength, the off-loom weft density significantly deviates from the on-loom value. On the basis of ECF design technique and the basic shed geometry, this study rebuilt the relative motion relationship among the front rest, the cloth fell, the back rest, and the take-up length, and modified the weft density on loom to achieve continuous weaving process of TCT fabric as well as the uniform porosity. And then, a computerized weaving procedure based on the rebuilt relationship was developed to automatically weave TCT fabric with different weaves on the customized shuttle loom. As a result, the uniform porosity of those samples validated the proposed weaving techniques.